Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer

被引:192
作者
Impellizzeri, Franco M. [1 ]
Bizzini, Mario [1 ]
Rampinini, Ermanno [2 ]
Cereda, Ferdinando [3 ]
Maffiuletti, Nicola A. [1 ]
机构
[1] Schluthess Clin, Neuromuscular Res Lab, CH-8008 Zurich, Switzerland
[2] Mapei Sport Res Ctr, Human Performance Lab, Castellanza, Varese, Italy
[3] Univ Cattolica, Milan, Italy
关键词
asymmetry; hamstring; quadriceps; reproducibility; torque; work;
D O I
10.1111/j.1475-097X.2007.00786.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The main aim of this study was to examine the absolute and relative reliability of some commonly used strength imbalance indices such as concentric hamstring-to-concentric quadriceps ratio, eccentric hamstring-to-concentric quadriceps ratio and bilateral concentric and eccentric strength ratios. An additional aim was to examine the reliability of the peak torque and work of the knee extensor and flexor muscles measured using the Cybex NORM dynamometer. Eighteen physically active healthy subjects (mean +/- standard deviation, age 23 +/- 3 years, height 176 +/- 5 cm, body mass 74 +/- 8 kg) were tested three times with 96 h between sessions. Peak torque, average work, unilateral and bilateral ratios were determined at 60, 120, 180 and -60 degrees s(-1). Low (0.34) to moderate (0.87) relative reliability (intraclass correlation coefficient, ICC) was found for strength imbalance ratios with eccentric hamstring-to-concentric quadriceps ratio showing the greater ICC (> 0.80). High ICC values (0.90-0.98) were found for peak torque and average work. Absolute reliability (standard error of measurement) ranged from 3.2% to 8.7% for strength imbalance ratios and from 4.3% to 7.7% for peak torque and average work measurements. This study established the reliability of the most common strength imbalance ratios and of absolute isokinetic muscle strength assessed using the Cybex NORM.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 48 条
[1]   ISOKINETIC HAMSTRING QUADRICEPS STRENGTH RATIO - INFLUENCE FROM JOINT ANGULAR VELOCITY, GRAVITY CORRECTION AND CONTRACTION MODE [J].
AAGAARD, P ;
SIMONSEN, EB ;
TROLLE, M ;
BANGSBO, J ;
KLAUSEN, K .
ACTA PHYSIOLOGICA SCANDINAVICA, 1995, 154 (04) :421-427
[2]   Isokinetic muscle strength and capacity for muscular knee joint stabilization in elite sailors [J].
Aagaard, P ;
Simonsen, EB ;
Beyer, N ;
Larsson, B ;
Magnusson, P ;
Kjaer, M .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1997, 18 (07) :521-525
[3]   A new concept for isokinetic hamstring: Quadriceps muscle strength ratio [J].
Aagaard, P ;
Simonsen, EB ;
Magnusson, SP ;
Larsson, B ;
Dyhre-Poulsen, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (02) :231-237
[4]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[5]   INTRAMACHINE AND INTERMACHINE RELIABILITY FOR SELECTED DYNAMIC MUSCLE PERFORMANCE TESTS [J].
BANDY, WD ;
MCLAUGHLIN, S .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1993, 18 (05) :609-613
[6]   Intramachine and intermachine reproducibility of concentric performance: A study of the Con-Trex MJ and the Cybex Norm dynamometers [J].
Bardis, C ;
Kalamara, E ;
Loucaides, G ;
Michaelides, M ;
Tsaklis, P .
ISOKINETICS AND EXERCISE SCIENCE, 2004, 12 (02) :91-97
[7]   Isokinetic strength testing does not predict hamstring injury in Australian Rules footballers [J].
Bennell, K ;
Wajswelner, H ;
Lew, P ;
Schall-Riaucour, A ;
Leslie, S ;
Plant, D ;
Cirone, J .
BRITISH JOURNAL OF SPORTS MEDICINE, 1998, 32 (04) :309-314
[8]   THE EFFECT OF VELOCITY AND GENDER ON LOAD RANGE DURING KNEE EXTENSION AND FLEXION EXERCISE ON AN ISOKINETIC DEVICE [J].
BROWN, LE ;
WHITEHURST, M ;
GILBERT, R ;
BUCHALTER, DN .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1995, 21 (02) :107-112
[9]  
Brown LE., 1993, ISOKINET EXERC SCI, V3, P160, DOI 10.3233/IES-1993-3307
[10]  
Capodaglio P, 2005, AGING CLIN EXP RES, V17, P174