摘要
Urea is an important indicator of liver and kidney disease, and very frequently determined in clinical chemistry. The reference measurement procedures (RMPs) for serum urea recognized by the Joint Committee for Traceability in Laboratory Medicine are spectrophotometry, and isotope dilution (ID)-mass spectrometry (MS) coupled with gas chromatography. This study investigated a candidate RMP (cRMP) for detecting serum urea directly via ID-liquid chromatography (LC)-MS/MS, without derivatization, which simplifies pre-processing samples. The cRMP was developed and evaluated relative to the recognized RMP, inter- and intra-laboratories. The intra-precisions were 1.35%, 1.98% and 1.47% at 4.95, 24.74 and 31.36 mmol/L, respectively; inter-precision was 2.10%, 2.60% and 2.10%. The relative bias for the measurement of standard human serum (SRM 909c) was -0.49%. The relative biases were 0.41% and 0.02% for IFCC-RELA (International Federation of Clinical Chemistry and Laboratory Medicine-External Quality Assessment Scheme [EQAS] for reference laboratories) 2015A and 2015B. The linearity response between 2.4 mmol/L and 53.7 mmol/L was R-2= 0.9989. No carryover, ion suppression, or interference was detected. Correlation was acceptable with the reference spectrophotometry (R-2 = 0.9985, P< 0.0001). Between our laboratory and other reference laboratories, the absolute deviation range for IFCC-RELA 2016A and 2016B was from -0.63 to 1.52 mmol/L. This well-characterized cRMP for urea can provide a base of accuracy for the traceability of clinical systems. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 129
页数:6
相关论文
共 50 条
  • [1] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Zhao, Haijian
    Zeng, Jie
    Zhang, Jiangtao
    Zhou, Weiyan
    Yan, Ying
    Wang, Yufei
    Wang, Mo
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7403 - 7411
  • [2] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Tianjiao Zhang
    Chuanbao Zhang
    Haijian Zhao
    Jie Zeng
    Jiangtao Zhang
    Weiyan Zhou
    Ying Yan
    Yufei Wang
    Mo Wang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7403 - 7411
  • [3] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Qiaoxuan Zhang
    Liqiao Han
    Songbai Zheng
    Fen Ouyang
    Xiaobin Wu
    Jun Yan
    Min Zhan
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4471 - 4481
  • [4] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Zhang, Qiaoxuan
    Han, Liqiao
    Zheng, Songbai
    Ouyang, Fen
    Wu, Xiaobin
    Yan, Jun
    Zhan, Min
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) : 4471 - 4481
  • [5] A candidate reference measurement procedure for quantification of glycocholic acid in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry
    Zhang, Pingping
    Wang, Huimin
    Liang, Man
    Wang, Zhifang
    Liu, Chunlong
    Han, Yanlin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (23) : 5121 - 5131
  • [6] Development of a candidate reference method for determination of tyrosine in serum by isotope dilution liquid chromatography-tandem mass spectrometry
    Lee, Hwashim
    Park, Sangryoul
    Kim, Byungjoo
    Lee, Gaeho
    ANALYTICAL SCIENCES, 2007, 23 (03) : 299 - 303
  • [7] Development of a Candidate Reference Method for Determination of Tyrosine in Serum by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Hwashim Lee
    Sangryoul Park
    Byungjoo Kim
    Gaeho Lee
    Analytical Sciences, 2007, 23 : 299 - 303
  • [8] Determination of serum amantadine by liquid chromatography-tandem mass spectrometry
    Arndt, T
    Guessregen, B
    Hohl, A
    Reis, J
    CLINICA CHIMICA ACTA, 2005, 359 (1-2) : 125 - 131
  • [9] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01): : 50 - 57
  • [10] Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Stenman, Ulf-Hakan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 113 - 118