Simulating stress-dependent fluid flow in a fractured core sample using real-time X-ray CT data

被引:27
|
作者
Kling, Tobias [1 ]
Huo, Da [2 ]
Schwarz, Jens-Oliver [3 ,4 ]
Enzmann, Frieder [3 ]
Benson, Sally [2 ]
Blum, Philipp [1 ]
机构
[1] Karlsruhe Inst Technol KIT, Inst Appl Geosci AGW, D-76131 Karlsruhe, Germany
[2] Stanford Univ, Sch Earth Sci, Stanford, CA 94305 USA
[3] Johannes Gutenberg Univ Mainz, Inst Geosci, D-55128 Mainz, Germany
[4] Math2Market GmbH, D-67657 Kaiserslautern, Germany
关键词
POSITRON-EMISSION-TOMOGRAPHY; COMPUTED-TOMOGRAPHY; CUBIC LAW; CAPILLARY-PRESSURE; RELATIVE PERMEABILITY; TRIAXIAL COMPRESSION; NUMERICAL-ANALYSIS; DAMAGE EVOLUTION; MULTIPHASE-FLOW; ROCK FRACTURES;
D O I
10.5194/se-7-1109-2016
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Various geoscientific applications require a fast prediction of fracture permeability for an optimal workflow. Hence, the objective of the current study is to introduce and validate a practical method to characterize and approximate single flow in fractures under different stress conditions by using a core-flooding apparatus, in situ X-ray computed tomography (CT) scans and a finite-volume method solving the Navier-Stokes-Brinkman equations. The permeability of the fractured sandstone sample was measured stepwise during a loading-unloading cycle (0.7 to 22.1MPa and back) to validate the numerical results. Simultaneously, the pressurized core sample was imaged with a medical X-ray CT scanner with a voxel dimension of 0.5 x 0.5 x 1.0 mm(3). Fracture geometries were obtained by CT images based on a modification of the simplified missing attenuation (MSMA) approach. Simulation results revealed both qualitative plausibility and a quantitative approximation of the experimentally derived permeabilities. The qualitative results indicate flow channeling along several preferential flow paths with less pronounced tortuosity. Significant changes in permeability can be assigned to temporal and permanent changes within the fracture due to applied stresses. The deviations of the quantitative results appear to be mainly caused by both local underestimation of hydraulic properties due to compositional matrix heterogeneities and the low CT resolution affecting the accurate capturing of sub-grid-scale features. Both affect the proper reproduction of the actual connectivity and therefore also the depiction of the expected permeability hysteresis. Furthermore, the threshold value CTmat (1862.6 HU) depicting the matrix material represents the most sensitive input parameter of the simulations. Small variations of CTmat can cause enormous changes in simulated permeability by up to a factor of 2.6 +/- 0.1 and, thus, have to be defined with caution. Nevertheless, comparison with further CT-based flow simulations indicates that the proposed method represents a valuable method to approximate actual permeabilities, particularly for smooth fractures (< 35 mu m). However, further systematic investigations concerning the applicability of the method are essential for future studies. Thus, some recommendations are compiled by also including suggestions of comparable studies.
引用
收藏
页码:1109 / 1124
页数:16
相关论文
共 11 条
  • [1] Stress-dependent fracture porosity and permeability of fractured coal: An in-situ X-ray tomography study
    Zhang, Guanglei
    Ranjith, P. G.
    Liang, Weiguo
    Haque, Asadul
    Perera, M. S. A.
    Li, Dongyin
    INTERNATIONAL JOURNAL OF COAL GEOLOGY, 2019, 213
  • [2] Characterizing locality- and scale-dependent heterogeneity in conglomerate core and associated fluid flow using X-ray CT imaging
    Han, Gidon
    Han, Weon Shik
    Kim, Kue-Young
    Baek, Johyun
    Kim, Minji
    Kim, Chan Yeong
    Lim, Jae-Hong
    JOURNAL OF HYDROLOGY, 2021, 602 (602)
  • [3] Petrophysical Characterization of Metamorphic Rocks using X-ray Micro-CT data - Implications for fluid flow
    Chakraborty, Ritwik
    Spaeth, Michael
    Kumar, Akash
    Busch, Benjamin
    Nestler, Britta
    Mamtani, Manish A.
    Hilgers, Christoph
    JOURNAL OF STRUCTURAL GEOLOGY, 2025, 191
  • [4] FPGA-Based Real-Time Data Acquisition for Ultrafast X-Ray Computed Tomography
    Windisch, Dominic
    Knodel, Oliver
    Juckeland, Guido
    Hampel, Uwe
    Bieberle, Andre
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (12) : 2779 - 2786
  • [5] Real-time X-ray imaging of mouse cerebral microvessels in vivo using a pixel temporal averaging method
    Yu, Fucheng
    Wang, Feixiang
    Li, Ke
    Du, Guohao
    Deng, Biao
    Xie, Honglan
    Yang, Guoyuan
    Xiao, Tiqiao
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 239 - 246
  • [6] Evaluation of Meso-damage Processes in Concrete by X-Ray CT Scanning Techniques Under Real-Time Uniaxial Compression Testing
    Tian, Wei
    Han, Nv
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2019, 38 (02)
  • [7] Performance evaluation of near-real time angular tube current modulation in X-ray computed tomography using real-time dosimeter: a phantom study
    Kosuke Matsubara
    Hiroki Kawashima
    Masanao Kobayashi
    Atsushi Fukuda
    Health and Technology, 2020, 10 : 1437 - 1443
  • [8] Performance evaluation of near-real time angular tube current modulation in X-ray computed tomography using real-time dosimeter: a phantom study
    Matsubara, Kosuke
    Kawashima, Hiroki
    Kobayashi, Masanao
    Fukuda, Atsushi
    HEALTH AND TECHNOLOGY, 2020, 10 (06) : 1437 - 1443
  • [9] Modeling photon-counting detectors for x-ray CT: spectral response and pulse-pileup effects and evaluation using real data
    Cammin, J.
    Xu, J.
    Barber, W. C.
    Iwanczyk, J. S.
    Hartsough, N. E.
    Taguchi, K.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [10] 4-D imaging of sub-second dynamics in pore-scale processes using real-time synchrotron X-ray tomography
    Dobson, Katherine J.
    Coban, Sophia B.
    McDonald, Samuel A.
    Walsh, Joanna N.
    Atwood, Robert C.
    Withers, Philip J.
    SOLID EARTH, 2016, 7 (04) : 1059 - 1073