Modification of polyacrylonitrile-derived carbon nanofibers and bacteriophages on screen-printed electrodes: A portable electrochemical biosensor for rapid detection of Escherichia coli

被引:18
|
作者
Wang, Ruo-Fan [1 ]
Wang, Reuben [1 ,2 ,3 ,4 ]
机构
[1] Natl Taiwan Univ, Inst Food Safety & Hlth, Coll Publ Hlth, Taipei, Taiwan
[2] Natl Taiwan Univ, Coll Publ Hlth, Publ Hlth Program, Taipei, Taiwan
[3] Natl Taiwan Univ, Global Innovat Joint Degree Program GIP TRIAD, Taipei, Taiwan
[4] Natl Taiwan Univ, Inst Food Safety & Hlth, Coll Publ Hlth, 17 Xuzhou Rd, Taipei City 100025, Taiwan
关键词
Electrochemical biosensor; Electrospinning; Screen-printed electrode; Bacteriophage; Escherichia coli; IMPEDANCE; WATER;
D O I
10.1016/j.bioelechem.2022.108229
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A facile method was developed for fabricating a disposable phage-based electrochemical biosensor for the detection of Escherichia coli. Bare screen-printed electrodes (SPEs) were modified using a two-step drop-casting method, in which polyacrylonitrile-derived electrospun carbon nanofibers (CNFs) were deposited, followed by E. coli bacteriophage immobilization. The deposition of CNFs increased the surface area for bacteriophage immobilization while maintaining a conductive link for ferro/ferricyanide redox transitions. Cyclic voltammetry and electrochemical impedance spectroscopy confirmed that the CNF modification increased the electron -transfer rate, whereas bacteriophages and E. coli blocked electron transfer at the electrode. The biosensor achieved a response within 10 min and a linear response in the E. coli concentration range of 10(2)-10(6) CFU/mL. A limit of detection (LOD) of 36 CFU/mL in phosphate-buffered saline was achieved, which is the lowest LOD reported thus far for phage-based disposable SPE sensors. The biosensor exhibited recovery rates between 106 % and 119 % for E. coli detection in apple juice. The proposed fabrication method allowed electrodes to be obtained from different production batches with remarkable consistency and reproducibility, and they remained stable at room temperature for one month. Thus, a phage-based disposable SPE that can be used for bacterial detection was developed for the first time.
引用
收藏
页数:10
相关论文
共 24 条
  • [21] Easy to use and rapid isolation and detection of a viral nucleic acid by using paramagnetic microparticles and carbon nanotubes-based screen-printed electrodes
    Adam, Vojtech
    Huska, Dalibor
    Hubalek, Jaromir
    Kizek, Rene
    MICROFLUIDICS AND NANOFLUIDICS, 2010, 8 (03) : 329 - 339
  • [22] Gold nano-flowers (Au NFs) modified screen-printed carbon electrode electrochemical biosensor for label-free and quantitative detection of glycated hemoglobin
    Wang, Xiao
    Su, Jing
    Zeng, Dongdong
    Liu, Gang
    Liu, Lizhuang
    Xu, Yi
    Wang, Chenguang
    Liu, Xinxin
    Wang, Lu
    Mi, Xianqiang
    TALANTA, 2019, 201 : 119 - 125
  • [23] A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii
    Dou, Wenchao
    Tang, Weilu
    Zhao, Guangying
    ELECTROCHIMICA ACTA, 2013, 97 : 79 - 85
  • [24] Green synthesis of copper(II) oxide nanoparticles covered on multiwalled carbon nanotubes modified screen-printed electrode as rapid electrochemical sensing platform for detection of doxepin
    Al-dolaimy, F.
    Tapia, Nelly Esther Flores
    Hussein, Talib Kh.
    Kaur, Mandeep
    Alhameedi, Dheyaa Yahaia
    Rasen, Fadhil A.
    Ramadan, Montather F.
    Khaleel, Luay Ali
    Alsalamy, Ali
    Asiri, Mohammed
    Elawady, Ahmed
    RESULTS IN CHEMISTRY, 2024, 7