Multiplex measurement of twelve tumor markers using a GMR multi-biomarker immunoassay biosensor

被引:81
作者
Gao, Yang [1 ,2 ]
Huo, Weisong [1 ,2 ]
Zhang, Lei [3 ]
Lian, Jie [4 ]
Tao, Wei [3 ]
Song, Chuan [3 ]
Tang, Jinping [3 ]
Shi, Stone [3 ]
Gao, Yunhua [1 ,2 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Photochem Convers & Optoelect Mat, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Dongguan Bosh Biotechnol LTD, Dongguan 523808, Guangdong, Peoples R China
[4] Peoples Publ Secur Univ China, Dept Forens Sci, Beijing 100038, Peoples R China
关键词
GMR sensor chip; Microfluidic device; Magnetic nano-beads labelling; Twelve tumor markers; Multiplex measurement; QUANTUM DOTS; ELECTROCHEMILUMINESCENCE IMMUNOASSAY; MONOCLONAL-ANTIBODIES; BREAST-CANCER; CHIP; SERUM; TECHNOLOGIES; DIAGNOSTICS; CHALLENGES; MICROBEADS;
D O I
10.1016/j.bios.2018.08.060
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Tumor markers play an important role in the early diagnosis and therapeutic effect monitoring of tumors. Combined detection of multiple tumor markers is a realistic way of improving the sensitivity and specificity of cancer diagnosis. To achieve this, we studied and designed a giant magneto resistance (GMR) multi-biomarker immunoassay biosensor that can simultaneously detect twelve kinds of tumor markers by integrating a GMR sensor chip, a microfluidic device, a magnetic nano -beads label, and a double antibody sandwich immunoassay method. As a proof of concept, the proposed immunosensor was utilized to detect 12 tumor markers (AFP, CEA, CYFRA21-1, NSE, SCC, PG I, PG II, CA19-9, total PSA, free PSA, free-beta-hCG, Tg) and to screen patients with lung cancer, liver cancer, digestive tract cancer, prostatic cancer, etc. The immunosensor showed excellent sensitivity, accuracy, precision and stability. Designed as a POCT device, the immunosensor also allows for portability, able to perform rapid detection wherever necessary. As a multi-analyte assay, it provides significant advantages over single-analyte tests in terms of cost per test, labor and convenience. The system's ability to simultaneously measure the concentration of multiple markers in serum samples with excellent sensitivity and accuracy allows the immunosensor to be used for early tumor diagnosis.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 33 条
  • [1] Ultrasensitive electrochemiluminescence immunoassay for simultaneous determination of CA125 and CA15-3 tumor markers based on PAMAM-sulfanilic acid-Ru(bpy)32+ and PAMAM-CdTe@CdS nanocomposite
    Babamiri, Bahareh
    Hallaj, Rahman
    Salimi, Abdollah
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 99 : 353 - 360
  • [2] Rapid exponential elimination of free prostate-specific antigen contrasts the slow, capacity-limited elimination of PSA complexed to alpha1-antichymotrypsin from serum
    Björk, T
    Ljungberg, B
    Piironen, T
    Abrahamsson, PA
    Pettersson, K
    Cockett, ATK
    Lilja, H
    [J]. UROLOGY, 1998, 51 (01) : 57 - 62
  • [3] Quantum dot-based lab-on-a-bead system for multiplexed detection of free and total prostate-specific antigens in clinical human serum samples
    Brazhnik, Kristina
    Sokolova, Zinaida
    Baryshnikova, Maria
    Bilan, Regina
    Efimov, Anton
    Nabiev, Igor
    Sukhanova, Alyona
    [J]. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2015, 11 (05) : 1065 - 1075
  • [4] Opportunities and challenges for the application of microfluidic technologies in point-of-care veterinary diagnostics
    Busin, Valentina
    Wells, Beth
    Kersaudy-Kerhoas, Maiwenn
    Shu, Wenmaio
    Burgess, Stewart T. G.
    [J]. MOLECULAR AND CELLULAR PROBES, 2016, 30 (05) : 331 - 341
  • [5] Portable, one-step, and rapid GMR biosensor platform with smartphone interface
    Choi, Joohong
    Gani, Adi Wijaya
    Bechstein, Daniel J. B.
    Lee, Jung-Rok
    Utz, Paul J.
    Wang, Shan X.
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 85 : 1 - 7
  • [6] Czinn S.J., 2011, Pediatric Gastrointestinal and Liver Disease, V4th ed., P262
  • [7] A disposable immunosensor device for point-of-care test of tumor marker based on copper-mediated amplification
    Ge, Shenguang
    Ge, Lei
    Yan, Mei
    Song, Xianrang
    Yu, Jinghua
    Liu, Shanshan
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 43 : 425 - 431
  • [8] Multiplex electrochemiluminescence immunoassay of two tumor markers using multicolor quantum dots as labels and graphene as conducting bridge
    Guo, Zhiyong
    Hao, Tingting
    Du, Shuping
    Chen, Beibei
    Wang, Zebo
    Li, Xing
    Wang, Sui
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 44 : 101 - 107
  • [9] Huo W., 2015, IEEE T MAGN, V51, P1
  • [10] Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
    Jung, Woos Eok
    Han, Jungyoup
    Choi, Jin-Woo
    Ahn, Chong H.
    [J]. MICROELECTRONIC ENGINEERING, 2015, 132 : 46 - 57