High-Precision Capacitive Sensors for Intravenous Fluid Monitoring in Hospitals

被引:22
作者
Salmaz, Uzma [1 ]
Ahsan, M. A. H. [2 ]
Islam, Tarikul [1 ]
机构
[1] Jamia Millia Islamia, Dept Elect Engn, New Delhi 110025, India
[2] Jamia Millia Islamia, Dept Phys, New Delhi 110025, India
关键词
Capacitive sensors; droplet detection; intravenous fluid (IV) fluids; response parameters comparisons;
D O I
10.1109/TIM.2021.3102681
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Automatic detection of the presence of intravenous fluids (IVs) and measuring their drip rates are essential for intelligent health care applications. Conventionally, the drip rate is monitored manually by a gravimetric method that suffers from several drawbacks. Some smart commercial drip systems, which mostly work on the optical technique, have inaccuracy due to external light interference, temperature variation, and misalignment of a photodiode and photodetector. The main motivation of this work is to investigate the usefulness of the capacitive sensors for the noncontact detection and measurement of flow rates of IV fluids. There is no previous work on IV drop detection by the capacitive sensors. This article investigated three types of capacitive sensors, such as a cross capacitive, a semicylindrical, and a planar parallel plate to detect the presence of IV droplets in the fluid pipe nondestructively. The sensors are specially designed to fulfill the application needs, and simulated and fabricated with inexpensive double-sided copper-cladded flexible PCB substrates. Experiments are conducted with the sensors for four IV fluids typically used in hospitals to determine their response parameters, such as precision, drift, and drop rate, when the droplet passes through the inner electric field of the sensors. There is an instantaneous change in the value of capacitance due to a sudden change in the dielectric constant of a partially filled air medium. The distinctive capacitance peak enables to count the droplets, drip rate (0.4-m/s cross capacitive) with highly precise (0.036%), and drift-free readings. All the sensors can be used for the target application, but the cross capacitive sensor has single dimension accuracy.
引用
收藏
页数:9
相关论文
共 30 条
[1]   MEMS piezoresistive flow sensors for sleep apnea therapy [J].
Abbasnejad, Behrokh ;
Thorby, William ;
Razmjou, Amir ;
Jin, Dayong ;
Asadnia, Mohsen ;
Warkiani, Majid Ebrahimi .
SENSORS AND ACTUATORS A-PHYSICAL, 2018, 279 :577-585
[2]  
Alagundagi SS, 2018, INT CONF COMMUN SYST, P688, DOI 10.1109/COMSNETS.2018.8328296
[3]  
Analog Devices, AD 7150 EV BOARD
[4]  
[Anonymous], 2018, ADM INF PUMPS
[5]   Microwave TDR for Real-Time Control of Intravenous Drip Infusions [J].
Cataldo, Andrea ;
Cannazza, Giuseppe ;
Giaquinto, Nicola ;
Trotta, Amerigo ;
Andria, Gregorio .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (07) :1866-1873
[6]   A semi-cylindrical capacitive sensor with interface circuit using for fluidic measuring [J].
Chiang, Cheng-Ta ;
Huang, Yu-Chung .
2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, :2318-+
[7]   Numerical Investigations on Electric Field Characteristics with Respect to Capacitive Detection of Free-Flying Droplets [J].
Ernst, Andreas ;
Mutschler, Klaus ;
Tanguy, Laurent ;
Paust, Nils ;
Zengerle, Roland ;
Koltay, Peter .
SENSORS, 2012, 12 (08) :10550-10565
[8]   Noncontact Determination of Velocity and Volume of Nanoliter Droplets on the Fly [J].
Ernst, Andreas ;
Ju, Lin ;
Vondenbusch, Bernhard ;
Zengerle, Roland ;
Koltay, Peter .
IEEE SENSORS JOURNAL, 2011, 11 (08) :1736-1742
[9]  
Franke AD, 2009, MED J AUSTRALIA, V190, P718, DOI 10.5694/j.1326-5377.2009.tb02656.x
[10]   A miniaturized piezoresistive flow sensor for real-time monitoring of intravenous infusion [J].
Hagihghi, Reza ;
Razmjou, Amir ;
Orooji, Yasin ;
Warkiani, Majid E. ;
Asadnia, Mohsen .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (02) :568-576