Broken Kirschner or guide-wire retrieval: a report of 4 cases

被引:13
作者
Sen, Ramesh Kumar [1 ]
Tripathy, Sujit Kumar
Aggarwal, Sameer
Agarwal, Amit [2 ]
Goyal, Tarun [2 ]
Tahasildar, Naveen
Dhatt, Sarvdeep
机构
[1] Postgrad Inst Med Educ & Res, Dept Orthopaed, Sector 12, Chandigarh 160012, India
[2] AIIMS, Dept Orthopaed, New Delhi, India
关键词
Guide wire; Hip joint; Migration; Retrieval; FIXATION; MIGRATION; FRACTURE; FEMUR; NECK; PIN;
D O I
10.1177/112070001002000422
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Migration of a broken wire into the hip joint or pelvis during surgery is rare, but it can cause significant complications. Retrieval can be extremely difficult and hazardous. We report 4 cases of broken Kirschner or guide wire removal around the hip joint. Two wires were inside the hip joint and two had protruded into the pelvis. The problems encountered and techniques used for retrieval are discussed.
引用
收藏
页码:551 / 554
页数:4
相关论文
共 50 条
[41]   A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results [J].
Martijn Raaijmaakers ;
Frederik Gelaude ;
Karla De Smedt ;
Tim Clijmans ;
Jeroen Dille ;
Michiel Mulier .
BMC Musculoskeletal Disorders, 11
[42]   Migration of a Kirschner wire used in the fixation of a subcapital humeral fracture, causing cardiac tamponade -: Case report and review of literature [J].
Freund, E. ;
Nachman, R. ;
Gips, H. ;
Hiss, J. .
AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2007, 28 (02) :155-156
[43]   Retrieval of an endobronchial foreign body using a guide wire and angioplasty catheter [J].
Briggs, G. ;
Walker, R. W. M. .
ANAESTHESIA AND INTENSIVE CARE, 2007, 35 (03) :433-436
[44]   Cone over Guide Wire Technique for Difficult IVC Filter Retrieval [J].
Daniel S. Kassavin ;
George Constantinopoulos .
CardioVascular and Interventional Radiology, 2011, 34 :664-666
[45]   Symptomatic migration of a Kirschner wire into the spinal canal without, spinal cord injury: case report [J].
Minic, Ljubodrag ;
Lepic, Milan ;
Novakovic, Nenad ;
Mandic-Rajcevic, Stefan .
JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (02) :291-294
[46]   Successful removal of an intra-pericardic Kirschner wire via fluoroscopy-guided minimal invasive approach: a case report [J].
Georges, Olivier ;
De Dominicis, Florence ;
Ben Rahal, Malek ;
Le Pessot, Jules ;
Berna, Pascal ;
Arab, Osama Abou ;
Beyls, Christophe .
SURGICAL CASE REPORTS, 2024, 10 (01)
[47]   Treated With Retrograde Guide Wire Technique:A Case Report [J].
洪浪 ;
王洪 ;
尹秋林 ;
李林锋 ;
赖珩莉 ;
陆林祥 ;
李彬 ;
黄勤 ;
邱赟 .
South China Journal of Cardiology, 2009, 10 (01) :34-35
[48]   Technique for Retrieval of a Knotted and Entrapped Guide Wire After Central Venous Catheterization [J].
Yong, Yao Pey ;
Abisi, Said ;
Whitaker, Simon ;
Braithwaite, Bruce .
VASCULAR AND ENDOVASCULAR SURGERY, 2013, 47 (03) :225-227
[49]   Application prospects of tubular mechanics in vascular intervention medicine and example of tension-torque model of catheter and guide-wire string [J].
Li, Zifeng .
RESULTS IN ENGINEERING, 2020, 6
[50]   Broken guide wire - a fault of design?Le bris ďun guide métallique - un défaut de conception ? [J].
Enrico Monaca ;
Stefan Trojan ;
John Lynch ;
Manfred Doehn ;
Frank Wappler .
Canadian Journal of Anesthesia, 2005, 52 (8) :801-804