Broken Kirschner or guide-wire retrieval: a report of 4 cases

被引:13
作者
Sen, Ramesh Kumar [1 ]
Tripathy, Sujit Kumar
Aggarwal, Sameer
Agarwal, Amit [2 ]
Goyal, Tarun [2 ]
Tahasildar, Naveen
Dhatt, Sarvdeep
机构
[1] Postgrad Inst Med Educ & Res, Dept Orthopaed, Sector 12, Chandigarh 160012, India
[2] AIIMS, Dept Orthopaed, New Delhi, India
关键词
Guide wire; Hip joint; Migration; Retrieval; FIXATION; MIGRATION; FRACTURE; FEMUR; NECK; PIN;
D O I
10.1177/112070001002000422
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Migration of a broken wire into the hip joint or pelvis during surgery is rare, but it can cause significant complications. Retrieval can be extremely difficult and hazardous. We report 4 cases of broken Kirschner or guide wire removal around the hip joint. Two wires were inside the hip joint and two had protruded into the pelvis. The problems encountered and techniques used for retrieval are discussed.
引用
收藏
页码:551 / 554
页数:4
相关论文
共 50 条
[31]   Concomitant laparoscopy: An effective technique for successful retrieval of intra pelvic migrated broken guide pin [J].
Venkata, Gurava Reddy ;
Mootha, Aditya Krishna ;
Thayi, Chiranjeevi ;
Parekh, Venu Gopal ;
Ramireddy, Vinodh Kumar .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (04) :526-529
[32]   Contralateral migration of Kirschner wire from right acromioclavicular joint to left side of neck: a case report [J].
Ko, How-Yun ;
Lee, Ka-Wo .
JOURNAL OF MEDICAL CASE REPORTS, 2019, 13 (01)
[33]   Teaching basic trauma: validating FluoroSim, a digital fluoroscopic simulator for guide-wire insertion in hip surgery [J].
Sugand, Kapil ;
Wescott, Robert A. ;
Carrington, Richard ;
Hart, Alister ;
van Duren, Bernard H. .
ACTA ORTHOPAEDICA, 2018, 89 (04) :380-385
[34]   Migration of a broken Kirschner pin into thoracic spinal canal 4 years following internal fixation of a clavicle fracture [J].
Shu-Qing Wang ;
You-Shui Gao ;
Jiong Mei ;
Ming Ni ;
Jia-Qi Wang ;
Zhi-Li Zeng .
European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 :493-495
[35]   Migration of a broken Kirschner pin into thoracic spinal canal 4 years following internal fixation of a clavicle fracture [J].
Wang, Shu-Qing ;
Gao, You-Shui ;
Mei, Jiong ;
Ni, Ming ;
Wang, Jia-Qi ;
Zeng, Zhi-Li .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (06) :493-495
[36]   A novel syringe tube combined guide-wire technique for repositioning a nasobiliary catheter in endoscopic nasobiliary drainage [J].
Liu, Qunqing ;
Liu, Xiongxiang ;
Liu, Wen ;
Fu, Qiang ;
Wen, Yonghong ;
Tian, Zan ;
Lin, Yuan ;
Zhu, Xi ;
Li, Rong ;
Zhou, Xiangling ;
Liu, Lang .
ASIAN JOURNAL OF SURGERY, 2025, 48 (01) :231-235
[37]   Migration of a broken Kirschner wire from an acromioclavicular joint into the neck: a case reportMigration d’une broche de Kirschner cassée de l’articulation acromio-claviculaire vers le cou [J].
M. Motamedi ;
S. M. J. Mortazavi ;
S. H. Miresmaseeli .
European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 :19-21
[38]   Use of a Guide-wire as an Adjunct for the Safe Removal of a 'Stuck' Indwelling Central Venous Catheter at Risk for Breaking [J].
Urevick, Alexander J. ;
Briscoe, W. Eric ;
Harpstead, Edward ;
Koontz, Curtis S. ;
Bhattacharya, S. Dave .
AMERICAN SURGEON, 2023, 89 (09) :3898-3899
[39]   Transperitoneal guide-wire or drainage catheter placement for guidance of laparoscopic marsupialization of lymphocoeles post renal transplantation [J].
Tie, MLH ;
Rao, MM ;
Russell, C ;
Burapa, K .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (05) :1038-1041
[40]   A Novel Guide-Wire Technique for Repositioning a Nasobiliary Catheter from Mouth to Nostril without Using a Nelaton Tube [J].
Hamano, Tetsuya ;
Yoshida, Shuhei ;
Nishino, Takayoshi ;
Akao, Junichi ;
Shirato, Izumi ;
Tagata, Tomoko ;
Ikarashi, Yuichi ;
Mitsunaga, Yutaka ;
Shimada, Masahiko ;
Mitsunaga, Atsushi .