Surgical Morbidity of Invasive Monitoring in Epilepsy Surgery: An Experience from a Single Institution

被引:16
作者
Ozlen, Fatma [1 ]
Asan, Ziya [1 ]
Tanriverdi, Taner [1 ]
Kafadar, Ali [1 ]
Ozkara, Cigdem [2 ]
Ozyurt, Emin [1 ]
Uzan, Mustafa [1 ]
机构
[1] Istanbul Univ, Cerrahpasa Med Fac, Dept Neurosurg, Istanbul, Turkey
[2] Istanbul Univ, Cerrahpasa Med Fac, Dept Neurol, Istanbul, Turkey
关键词
Complications; Depth electrode; Epilepsy; Epilepsy surgery; Morbidity; Subdural grid; Subdural strip; SUBDURAL STRIP ELECTRODES; LONG-TERM; SELECTIVE AMYGDALOHIPPOCAMPECTOMY; HIPPOCAMPAL SCLEROSIS; COMPLICATIONS; CHILDREN; EFFICACY; OUTCOMES; LIFE;
D O I
10.5137/1019-5149.JTN.3080-10.0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
AIM: This paper aimed to provide information related to surgical and neurological complications encountered following intracranial electrode placements in patients with medically intractable epilepsy. MATERIAL and METHODS: Retrospective review of 70 patients with either subdural grid/strip or depth electrode implanted between 2004 and 2009 at the Epilepsy Unit in Cerrahpasa Medical Faculty. RESULTS: A total of 276 electrode implantations were performed in 70 patients. There were no deaths related to implantation. The occurrence of infection and intracranial hematoma were found to be 1.4 and 1.4%, respectively. A total of 1 patient (1.4%) showed transient neurological complications. The rate of overall morbidity including neurological complications was found to be 4.2% (n = 3). CONCLUSION: Based on our experience, intracranial electrode implantation is an effective and safe method with extremely low morbidity rate, especially in experienced hands.
引用
收藏
页码:364 / 372
页数:9
相关论文
共 34 条
[1]  
[Anonymous], SCHMIDEK SWEET OPERA
[2]  
[Anonymous], 1993, Referentially Oriented Cerebral MRI Anatomy: An Atlas of Stereotaxic Anatomical Correlations for Gray and White Matter
[3]   Surgical and neurological complications in a series of 708 epilepsy surgery procedures [J].
Behrens, E ;
Schramm, J ;
Zentner, J ;
Konig, R .
NEUROSURGERY, 1997, 41 (01) :1-9
[4]  
Bouvier G, 1987, SURGICAL TREATMENT E, P589
[5]   Morbidity associated with the use of intracranial electrodes for epilepsy surgery [J].
Burneo, JG ;
Steven, DA ;
McLachlan, RS ;
Parrent, AG .
CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2006, 33 (02) :223-227
[6]  
Cahan LD, 1990, NEUROLOGICAL SURG, P4271
[7]   Efficacy of and morbidity associated with stereoelectroencephalography using computerized tomography - or magnetic resonance imaging-guided electrode implantation [J].
de Almeida, AN ;
Olivier, A ;
Quesney, F ;
Dubeau, F ;
Savard, G ;
Andermann, F .
JOURNAL OF NEUROSURGERY, 2006, 104 (04) :483-487
[8]  
Engel Jr J, 1983, CLIN NEUROSCIENCES, P1349
[9]  
GIRVIN JP, 1991, EPILEPSY SURG, P653
[10]   Complications of invasive video-EEG monitoring with subdural grid electrodes [J].
Hamer, HM ;
Morris, HH ;
Mascha, EJ ;
Karafa, MT ;
Bingaman, WE ;
Bej, MD ;
Burgess, RC ;
Dinner, DS ;
Foldvary, NR ;
Hahn, JF ;
Kotagal, P ;
Najm, I ;
Wyllie, E ;
Lüders, HO .
NEUROLOGY, 2002, 58 (01) :97-103