Pitfalls and artifacts encountered in clinical MR imaging of the spine

被引:70
|
作者
Taber, KH
Herrick, RC
Weathers, SW
Kumar, AJ
Schomer, DF
Hayman, LA
机构
[1] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[2] Baylor Coll Med, Herbert J Frensley Ctr Imaging Res, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Psychiat & Behav Sci, Houston, TX 77030 USA
[4] Univ Texas, MD Anderson Cancer Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
关键词
images; artifact; magnetic resonance (MR); spine; MR;
D O I
10.1148/radiographics.18.6.9821197
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) imaging of the spine has become widely accepted as a valuable diagnostic tool. However, there are a number of artifacts and pitfalls associated with spinal MR imaging. Chemical shift artifacts may be induced by bone marrow, epidural fat, or intradural fat. Motion artifacts arise from several sources, which include respiration, flow Of fluids, and swallowing. Artifacts due to a nonuniform magnetic field,,, particularly noticeable within trabecular bone or at bone-soft tissue interfaces but may also be caused by incomplete fat saturation or the presence of metal near the spine. Protocol errors may cause artifacts such as saturation, phase wraparound, truncation, radio-frequency interference, shading, and partial volume averaging. Use of fat saturation, use of motion and flow compensation, and careful screening of patients for metal in clothing can help reduce the occurrence of artifacts. In addition, use of an optimal imaging technique is essential and should include use of the proper surface coil, field of view, and pulse sequence.
引用
收藏
页码:1499 / 1521
页数:23
相关论文
共 50 条
  • [31] MR Imaging Findings of a Leiomyosarcoma of the Thoracic Spine: A Case Report
    Tahara, K.
    Yamashita, K.
    Hiwatashi, A.
    Togao, O.
    Kikuchi, K.
    Endo, M.
    Otsuka, H.
    Oda, Y.
    Honda, H.
    CLINICAL NEURORADIOLOGY, 2016, 26 (02) : 229 - 233
  • [32] MR Imaging Findings of a Leiomyosarcoma of the Thoracic Spine: A Case Report
    K. Tahara
    K. Yamashita
    A. Hiwatashi
    O. Togao
    K. Kikuchi
    M. Endo
    H. Otsuka
    Y. Oda
    H. Honda
    Clinical Neuroradiology, 2016, 26 : 229 - 233
  • [33] In vitro and in vivo MR imaging of hyaline cartilage: Zonal anatomy, imaging pitfalls, and pathologic conditions
    Waldschmidt, JG
    Rilling, RJ
    KajdacsyBalla, AA
    Boynton, MD
    Erickson, SJ
    RADIOGRAPHICS, 1997, 17 (06) : 1387 - 1402
  • [34] Acute cervical spine injuries prospective MR imaging assessment at a level 1 trauma center
    Katzberg, RW
    Benedetti, PF
    Drake, CM
    Ivanovic, M
    Levine, RA
    Beatty, CS
    Nemzek, WR
    McFall, RA
    Ontell, FK
    Bishop, DM
    Bishop, DM
    Poirier, VC
    Chong, BW
    RADIOLOGY, 1999, 213 (01) : 203 - 212
  • [35] Lumbar spine:: Quantitative and qualitative assessment of positional (upright flexion and extension) MR imaging and myelography
    Wildermuth, S
    Zanetti, M
    Duewell, S
    Schmid, MR
    Romanowski, B
    Benini, A
    Böni, T
    Hodler, J
    RADIOLOGY, 1998, 207 (02) : 391 - 398
  • [36] MR-IMAGING ARTIFACTS THAT SIMULATE DISEASE - HOW TO RECOGNIZE AND ELIMINATE THEM
    ARENA, L
    MOREHOUSE, HT
    SAFIR, J
    RADIOGRAPHICS, 1995, 15 (06) : 1373 - 1394
  • [37] INEFFECTIVENESS OF AVERAGING FOR REDUCING MOTION ARTIFACTS IN HALF-FOURIER MR IMAGING
    WOOD, ML
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05): : 593 - 600
  • [38] Use of gadolinium chelates in MR imaging of the spine
    Bradley, WG
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 38 - 46
  • [39] Tophaceous gout of the spine: MR imaging features
    Hsu, CY
    Shih, TTF
    Huang, KM
    Chen, PQ
    Sheu, JJ
    Li, YW
    CLINICAL RADIOLOGY, 2002, 57 (10) : 919 - 925
  • [40] Extraforaminal stenosis in the lumbosacral spine - Efficacy of MR imaging in the coronal plane
    Hashimoto, M
    Watanabe, O
    Hirano, H
    ACTA RADIOLOGICA, 1996, 37 (05) : 610 - 613