Converter rating optimisation for a brushless doubly fed induction generator

被引:23
作者
Oraee, Ashknaz [1 ]
Abdi, Ehsan [2 ]
McMahon, R. A. [1 ]
机构
[1] Univ Cambridge, Elect Engn Div, Cambridge CB3 0FA, England
[2] Wind Technol Ltd, Cambridge CB4 0WS, England
关键词
asynchronous generators; power convertors; brushless machines; wind turbines; reactive power; power system management; power grids; power capacitors; brushless doubly fed induction generator; converter rating requirement optimisation; DFIG; wind turbine application; generator torque-speed requirement; reactive power management; grid low-voltage ride-through; LVRT; machine derating; capacitor bank; machine leakage inductance;
D O I
10.1049/iet-rpg.2014.0249
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article studies the converter rating requirement of a Brushless doubly-fed induction generator (DFIG) for wind turbine applications. Practical constraints such as the generator torque-speed requirement, reactive power management and grid low-voltage ride-through (LVRT) are considered. Experimental data have been used to obtain a realistic system model of a Brushless DFIG in a wind turbine. The study shows that there is a minimum converter rating, dependant on operating point, but this may not be achievable without machine derating. The use of a capacitor bank enables the converter ratings to be reduced without compromising the machine's performance. The effect of the machine's leakage inductance on the interplay of LVRT, achievable system power factor, converter rating and losses is investigated.
引用
收藏
页码:360 / 367
页数:8
相关论文
共 5 条
[1]   Performance analysis and testing of a 250 kW medium-speed brushless doubly-fed induction generator [J].
Abdi, Ehsan ;
McMahon, Richard ;
Malliband, Paul ;
Shao, Shiyi ;
Mathekga, Mmamolatelo Ezekiel ;
Tavner, Peter ;
Abdi, Salman ;
Oraee, Ashknaz ;
Long, Teng ;
Tatlow, Mark .
IET RENEWABLE POWER GENERATION, 2013, 7 (06) :631-638
[2]  
McMahon R. A., 2010, IET ELECTR POWER APP, V7, P1
[3]  
Piwko R, 2010, IEEE POWER ENERGY M, V8, P18, DOI 10.1109/MPE.2009.935560
[4]   Comparison of direct-drive and geared generator concepts for wind turbines [J].
Polinder, Henk ;
van der Pijl, Frank F. A. ;
de Vilder, Gert-Jan ;
Tavner, Peter J. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) :725-733
[5]   Low voltage ride-through of DFIG and brushless DFIG: Similarities and differences [J].
Tohidi, S. ;
Tavner, P. ;
McMahon, R. ;
Oraee, H. ;
Zolghadri, M. R. ;
Shao, S. ;
Abdi, E. .
ELECTRIC POWER SYSTEMS RESEARCH, 2014, 110 :64-72