A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time

被引:104
作者
Buxi, Dilpreet [1 ]
Redoute, Jean-Michel [1 ]
Yuce, Mehmet Rasit [1 ]
机构
[1] Monash Univ, Dept Elect & Comp Syst Engn, Melbourne, Vic 3004, Australia
关键词
ambulatory blood pressure; pulse arrival time; pulse transit time; INDEPENDENT COMPONENT ANALYSIS; WAVE VELOCITY; MOTION ARTIFACT; ARRIVAL-TIME; CUFF-LESS; ARTERIAL STIFFNESS; PREEJECTION PERIOD; HEART SOUNDS; SENSOR; MANAGEMENT;
D O I
10.1088/0967-3334/36/3/R1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Blood pressure monitoring based on pulse transit or arrival time has been the focus of much research in order to design ambulatory blood pressure monitors. The accuracy of these monitors is limited by several challenges, such as acquisition and processing of physiological signals as well as changes in vascular tone and the pre-ejection period. In this work, a literature survey covering recent developments is presented in order to identify gaps in the literature. The findings of the literature are classified according to three aspects. These are the calibration of pulse transit/arrival times to blood pressure, acquisition and processing of physiological signals and finally, the design of fully integrated blood pressure measurement systems. Alternative technologies as well as locations for the measurement of the pulse wave signal should be investigated in order to improve the accuracy during calibration. Furthermore, the integration and validation of monitoring systems needs to be improved in current ambulatory blood pressure monitors.
引用
收藏
页码:R1 / R26
页数:26
相关论文
共 149 条
[51]   Development of a temperature-controlled miniature enclosure for monitoring poor perfusion photoplethysmographic signals [J].
Foo, Jong Yong Abdiel .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (09) :N67-N75
[52]  
Foo Jong Yong Abdiel, 2006, Technol Health Care, V14, P97
[53]  
Fuke S, 2013, IEEE ENG MED BIO, P6107, DOI 10.1109/EMBC.2013.6610946
[54]  
Fung P, 2004, P ANN INT IEEE EMBS, V26, P738
[55]   PULSE TRANSIT-TIME AS AN INDICATOR OF ARTERIAL BLOOD-PRESSURE [J].
GEDDES, LA ;
VOELZ, MH ;
BABBS, CF ;
BOURLAND, JD ;
TACKER, WA .
PSYCHOPHYSIOLOGY, 1981, 18 (01) :71-74
[56]   Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method [J].
Gesche, Heiko ;
Grosskurth, Detlef ;
Kuechler, Gert ;
Patzak, Andreas .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) :309-315
[57]  
Gu WB, 2008, 2008 5TH INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, P292
[58]   A Long-term Wearable Vital Signs Monitoring System using BSN [J].
Guo, D. G. ;
Tay, Francis E. H. ;
Xu, L. ;
Yu, L. M. ;
Nyan, M. N. ;
Chong, F. W. ;
Yap, K. L. ;
Xu, B. .
11TH EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN - ARCHITECTURES, METHODS AND TOOLS : DSD 2008, PROCEEDINGS, 2008, :825-830
[59]  
Guyton AC, 2006, TXB MED PHYSL
[60]   A new method for pulse oximetry possessing inherent insensitivity to artifact [J].
Hayes, MJ ;
Smith, PR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (04) :452-461