Non-contact sensing of neonatal pulse rate using camera-based imaging: a clinical feasibility study

被引:100
|
作者
Paul, M. [1 ]
Karthik, S. [2 ]
Joseph, J. [2 ]
Sivaprakasam, M. [2 ]
Kumutha, J. [3 ]
Leonhardt, S. [1 ]
Antink, C. Hoog [1 ]
机构
[1] Rhein Westfal TH Aachen, Med Informat Technol MedIT, Helmholtz Inst Biomed Engn, Pauwelsstr 20, D-52074 Aachen, Germany
[2] Healthcare Technol Innovat Ctr HTIC, IIT Madras Res Pk, Chennai 600113, Tamil Nadu, India
[3] Saveetha Med Coll, Chennai 602105, Tamil Nadu, India
关键词
photoplethysmography; photoplethysmography imaging; pulse rate; heart rate; camera-based; remote; non-contact; neonate; infant;
D O I
10.1088/1361-6579/ab755c
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Neonates and infants are patients who would benefit from less invasive vital sign sensing, especially from fewer cables and the avoidance of adhesive electrodes. Photoplethysmography imaging (PPGI) has been studied for medical applications in recent years: it is possible to assess various vital signs remotely, non-invasively, and without contact by using video cameras and light. However, studies on infants and especially on neonates in clinical settings are still rare. Hence, we conducted a single-center study to assess heart activity by estimating the pulse rate (PR) of 19 neonates. Approach: Time series were generated from tracked regions of interest (ROIs) and PR was estimated via a joint time-frequency analysis using a short-time Fourier transform. Artifacts, for example, induced by movement, were detected and flagged by applying a signal quality index in the frequency domain. Main results: The feasibility of PR estimation was demonstrated using visible light and near-infrared light at 850 nm and 940 nm, respectively: the estimated PR was as close as 3 heartbeats per minute in artifact-free time segments. Furthermore, an improvement could be shown when selecting the best performing ROI compared to the ROI containing the whole body. The main challenges are artifacts from motion, light sources, medical devices, and the detection and tracking of suitable regions for signal retrieval. Nonetheless, the PR extracted was found to be comparable to the contact-based photoplethysmography reference and is, therefore, a viable replacement if robust signal retrieval is ensured. Significance: Neonates are seldom measured by PPGI and studies reporting measurements on darker skin tones are rare. In this work, not only a single camera was used, but a synchronized camera setup using multiple wavelengths. Various ROIs were used for signal extraction to examine the capabilities of PPGI. In addition, qualitative observations regarding camera parameters and noise sources were reported and discussed.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Non-contact Measurement of Human Heart Rate Using Low Cost Video Camera
    Sharma, Naveen
    Kaman, Surjit
    Mahapatra, Prasant K.
    2019 FIFTH INTERNATIONAL CONFERENCE ON IMAGE INFORMATION PROCESSING (ICIIP 2019), 2019, : 58 - 62
  • [32] Long-range non-contact imaging photoplethysmography: Cardiac pulse wave sensing at a distance
    Blackford, Ethan B.
    Estepp, Justin R.
    Piasecki, Alyssa M.
    Bowers, Margaret A.
    Klosterman, Samantha L.
    OPTICAL DIAGNOSTICS AND SENSING XVI: TOWARD POINT-OF-CARE DIAGNOSTICS, 2016, 9715
  • [33] Feasibility of Exploiting Physiological and Motion Features for Camera-based Sleep Staging: A Clinical Study
    Wang, Qiongyan
    Cheng, Hanrong
    Wang, Wenjin
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [34] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Lalit Maurya
    Reyer Zwiggelaar
    Deepak Chawla
    Prasant Mahapatra
    Journal of Clinical Monitoring and Computing, 2023, 37 : 815 - 828
  • [35] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Maurya, Lalit
    Zwiggelaar, Reyer
    Chawla, Deepak
    Mahapatra, Prasant
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (03) : 815 - 828
  • [36] Feasibility study on back analysis based on non-contact measurement of tunnels
    Lu, Zhi-Peng
    Wang, Ming-Yuan
    Liu, Guo-Bin
    Shuili Xuebao/Journal of Hydraulic Engineering, 2007, 38 (02): : 244 - 249
  • [37] Non-contact imaging colorimeter for human tooth color assessment using a digital camera
    Ng, D
    Allebach, JP
    Analoui, M
    Pizlo, Z
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2003, 47 (06) : 531 - 542
  • [38] On the Feasibility of Non-contact Cardiac Motion Sensing for Emerging Heart-based Biometrics
    Zhuang, Yan
    Song, Chen
    Lin, Feng
    Li, Yiran
    Li, Changzhi
    Xu, Wenyao
    2016 IEEE RADIO AND WIRELESS SYMPOSIUM (RWS), 2016, : 204 - 206
  • [39] Using Non-Contact Imaging Photoplethysmography to Recover Diurnal Patterns in Heart Rate
    McDuff, Daniel
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6830 - 6833
  • [40] Non-contact detection of cardiac rate based on visible light imaging device
    Zhu, Huishi
    Zhao, Yuejin
    Dong, Liquan
    OPTICS AND PHOTONICS FOR INFORMATION PROCESSING VI, 2012, 8498