Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a, R404A and R410A

被引:191
作者
Heredia-Aricapa, Y. [1 ]
Belman-Flores, J. M. [1 ]
Mota-Babiloni, A. [2 ]
Serrano-Arellano, J. [3 ]
Garcia-Pabon, Juan J. [4 ]
机构
[1] Univ Guanajuato, Dept Mech Engn, Engn Div, Campus Irapuato Salamanca, Guanajuato 36885, Mexico
[2] Univ Jaume 1, Dept Mech Engn & Construct, ISTENER Res Grp, Av Vicent Sos Baynat, Castellon De La Plana 12071, Spain
[3] Inst Tecnol Super Huichapan ITESHU TecNM, Div Arquitectura, Dom Conocido S-N, Huichapan 42411, Hgo, Mexico
[4] Fed Univ Itajuba UNIFEI, Inst Mech Engn, Av BPS 1303, BR-37500903 Itajuba, Brazil
关键词
Review; HFC replacement; Refrigeration and air conditioning; Low GWP mixtures; Coefficient of performance; Energy; DROP-IN REPLACEMENT; EXERGY ANALYSIS; PERFORMANCE; ALTERNATIVES; SYSTEM; SUBSTITUTION; ENERGY; R1234YF; CYCLE;
D O I
10.1016/j.ijrefrig.2019.11.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current European F-gas regulation establishes restrictions in the use of fluoride refrigerants with a high global warming potential (GWP) in applications of refrigeration and air conditioning (RAC) systems. Moreover, a gradual limitation on the GWP weight of the fluoride refrigerants placed on the market is ongoing and will end with approximately one-fifth of today's offer. In this context, many of the RAC systems operate with refrigerants R134a, R404A, and R410A that have GWP values of 1300, 3943 and 2088, respectively, are being forced to be replaced by environmentally friendly alternatives, like hydrofluoroolefin (HFO) refrigerants and their mixtures with hydrofluorocarbons (HFC), which can be designed to present intermediate characteristics and become the ideal candidate many RAC applications. This work presents the most recent HFC/HFO/HC/R744 refrigerant mixture options for an alternative to the refrigerants mentiond above and compares their energetic and performance with the early developed mixture prototypes. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:113 / 123
页数:11
相关论文
共 50 条
  • [31] Experimental evaluation of low-GWP refrigerants R513A, R1234yf and R436A as alternatives for R134a in a cascade refrigeration cycle with R744
    Ojeda, Frank William Adolfo Blanco
    Queiroz, Marcus Vinicius Almeida
    Pico, David Fernando Marcucci
    Parise, Jose Alberto dos Reis
    Bandarra Filho, Enio Pedone
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 175 - 187
  • [32] Experimental study of an R1234ze(E)/R134a mixture (R450A) as R134a replacement
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Barragan-Cervera, Angel
    Moles, Francisco
    Peris, Bernardo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 51 : 52 - 58
  • [33] ANN approach for irreversibility analysis of vapor compression refrigeration system using R134a/LPG blend as replacement of R134a
    Gill, Jatinder
    Singh, Jagdev
    Ohunakin, Olayinka S.
    Adelekan, Damola S.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 135 (04) : 2495 - 2511
  • [34] Experimental and Simulation Study of the Latest HFC/HFO and Blend of Refrigerants in Vapour Compression Refrigeration System as an Alternative of R134a
    Prasad, Uma Shankar
    Mishra, Radhey Shyam
    Das, Ranadip Kumar
    Soni, Hargovind
    PROCESSES, 2023, 11 (03)
  • [35] REPLACEMENT OF R404A AT HIGH CONDENSATION TEMPERATURE USING R454C AND R455A
    Ramiro Haro-Ortuno, Jorge
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Moles, Francisco
    Barragan-Cervera, Angel
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 331 - 338
  • [36] Research on flammability of R290/R134a, R600a/R134a and R600a/R290 refrigerant mixtures
    Cai, Dehua
    Hao, Zian
    Xu, Hao
    He, Guogeng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 137 : 53 - 61
  • [37] Low GWP Fluids for Replacing R134a in an Air-Conditioning System
    Li, Houpei
    Peng, Jinqing
    6TH IIR CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR2021), 2021, : 350 - 357
  • [38] The cooling rate of the heated vapor compression cycle in case of using refrigerants R134a, R22, and R600a
    Abd-Elhady, Mohamed Salama
    Melad, Emmanoueil Bishara
    Abd-Elhalim, Mohamed
    Ahmed, Seif Alnasr
    ARCHIVES OF THERMODYNAMICS, 2021, 42 (02) : 11 - 30
  • [39] Experimental assessment of R134a and its lower GWP alternative R513A
    Mota-Babiloni, Adrian
    Makhnatch, Pavel
    Khodabandeh, Rahmatollah
    Navarro-Esbri, Joaquin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 74 : 682 - 688
  • [40] Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator
    Rangel-Hernandez, V. H.
    Belman-Flores, J. M.
    Rodriguez-Valderrama, D. A.
    Pardo-Cely, D.
    Rodriguez-Munoz, A. P.
    Ramirez-Minguela, J. J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 113 - 123