Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a, R404A and R410A

被引:201
作者
Heredia-Aricapa, Y. [1 ]
Belman-Flores, J. M. [1 ]
Mota-Babiloni, A. [2 ]
Serrano-Arellano, J. [3 ]
Garcia-Pabon, Juan J. [4 ]
机构
[1] Univ Guanajuato, Dept Mech Engn, Engn Div, Campus Irapuato Salamanca, Guanajuato 36885, Mexico
[2] Univ Jaume 1, Dept Mech Engn & Construct, ISTENER Res Grp, Av Vicent Sos Baynat, Castellon De La Plana 12071, Spain
[3] Inst Tecnol Super Huichapan ITESHU TecNM, Div Arquitectura, Dom Conocido S-N, Huichapan 42411, Hgo, Mexico
[4] Fed Univ Itajuba UNIFEI, Inst Mech Engn, Av BPS 1303, BR-37500903 Itajuba, Brazil
关键词
Review; HFC replacement; Refrigeration and air conditioning; Low GWP mixtures; Coefficient of performance; Energy; DROP-IN REPLACEMENT; EXERGY ANALYSIS; PERFORMANCE; ALTERNATIVES; SYSTEM; ENERGY; SUBSTITUTION; R1234YF; CYCLE;
D O I
10.1016/j.ijrefrig.2019.11.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current European F-gas regulation establishes restrictions in the use of fluoride refrigerants with a high global warming potential (GWP) in applications of refrigeration and air conditioning (RAC) systems. Moreover, a gradual limitation on the GWP weight of the fluoride refrigerants placed on the market is ongoing and will end with approximately one-fifth of today's offer. In this context, many of the RAC systems operate with refrigerants R134a, R404A, and R410A that have GWP values of 1300, 3943 and 2088, respectively, are being forced to be replaced by environmentally friendly alternatives, like hydrofluoroolefin (HFO) refrigerants and their mixtures with hydrofluorocarbons (HFC), which can be designed to present intermediate characteristics and become the ideal candidate many RAC applications. This work presents the most recent HFC/HFO/HC/R744 refrigerant mixture options for an alternative to the refrigerants mentiond above and compares their energetic and performance with the early developed mixture prototypes. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:113 / 123
页数:11
相关论文
共 75 条
[1]   Natural and synthetic refrigerants, global warming: A review [J].
Abas, Naeem ;
Kalair, Ali Raza ;
Khan, Nasrullah ;
Haider, Aun ;
Saleem, Zahid ;
Saleem, Muhammad Shoaib .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 90 :557-569
[2]  
Abdelaziz O., 2016, ORNLTM2016513
[3]   Thermodynamic performance of automobile air conditioners working with R430A as a drop-in substitute to R134a [J].
Abraham, J. D. Andrew Pon ;
Mohanraj, M. .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (05) :2071-2086
[4]   Experimental Studies of a Domestic Refrigerator Using R290/R600a Zeotropic Blends [J].
Agrawal, Neeraj ;
Patil, Shriganesh ;
Nanda, Prasant .
INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 :425-430
[5]  
[Anonymous], INT J RETRIGERATION
[6]  
[Anonymous], 2002, P 5 IIR GUSST LOR C
[7]  
[Anonymous], EXPT EVALUATION PERF
[8]  
[Anonymous], 2018, INT COMPRESSOR ENG C
[9]  
[Anonymous], P 13 IR NAT CHEM ENG
[10]  
[Anonymous], 2019, Coviability of Social and Ecological Systems: Reconnecting Mankind to the Biosphere in an Era of Global Change