Accurate length adjustment of aortocoronary saphenous vein bypass grafts

被引:11
作者
Durrani, A [1 ]
Sim, EKM [1 ]
Grignani, RT [1 ]
机构
[1] Natl Univ Singapore Hosp, Dept Cardiac, Singapore 119074, Singapore
关键词
D O I
10.1016/S0003-4975(98)00630-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We describe a simple method for tailoring the length of aortocoronary saphenous vein grafts. The objective is to prevent any kinking of the these grafts, which may compromise blood now in them and lead to their early occlusion. (Ann Thorac Surg 1998;66:966-7) (C) 1998 by The Society of Thoracic Surgeons.