Swept source OCT imaging of human anterior segment at 200 kHz

被引:0
|
作者
Karnowski, Karol [1 ]
Gora, Michalina [1 ]
Kaluzny, Bartlomiej [2 ]
Huber, Robert [3 ]
Szkulmowski, Maciej [1 ]
Kowalczyk, Andrzej [1 ]
Wojtkowski, Maciej [1 ]
机构
[1] Nicolaus Copernicus Univ, Inst Phys, Ul Grudziadzka 5, PL-87100 Torun, Poland
[2] Coll Med UMK, Dept Ophthalmol, Bydgoszcz, Poland
[3] Ludwig Maximilians Univ Munchen, Deptartement Phys, Munich, Germany
来源
OPHTHALMIC TECHNOLOGIES XIX | 2009年 / 7163卷
关键词
Optical Coherence Tomography; Fourier domain detection methods; swept source OCT; anterior segment of the eye; HIGH-SPEED; LASER;
D O I
10.1117/12.808555
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We present applicability of the high speed swept-source optical coherence tomography for in vivo imaging of the anterior segment of the human eye. Three dimensional imaging of the cornea with reduced motion artifacts is possible by using swept source with Fourier domain mode locking operating at 200kHz with 1300nm central wavelength. High imaging speeds allow for assessment of anterior and posterior corneal topography and generation of thickness and elevation maps.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range
    Gora, Michalina
    Karnowski, Karol
    Szkulmowski, Maciej
    Kaluzny, Bartlomiej J.
    Huber, Robert
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPTICS EXPRESS, 2009, 17 (17): : 14880 - 14894
  • [2] Segmentation of anterior segment boundaries in swept source OCT images
    Marin, Yoel Garcia
    Skrok, Marta
    Siedlecki, Damian
    Vincent, Stephen J.
    Collins, Michael J.
    Alonso-Caneiro, David
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2021, 41 (03) : 903 - 915
  • [3] Whole anterior segment and retinal swept source OCT for comprehensive ocular screening
    Rodriguez-Aramendia, Ana
    Diaz-Douton, Fernando
    Fernandez-Trullas, Jose
    Falgueras, Pol
    Gonzalez, Laura
    Pujol, Jaume
    Grulkowski, Ireneusz
    Guell, Jose Luis
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (03) : 1263 - 1278
  • [4] Repeatability assessment of anterior segment measurements in myopic patients using an anterior segment OCT with placido corneal topography and agreement with a swept-source OCT
    Wang, Hao
    Zhu, Li-Shuang
    Pang, Chen-Jiu
    Fan, Qi
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [5] Agreement between anterior segment swept source-OCT and Scheimpflug imaging corneal aberration measurements in healthy eyes
    Perez-Bartolome, Francisco
    Feu-Basilio, Silvia
    Rocha-de Lossada, Carlos
    Blanco-Dominguez, Irene
    Torras-Sanvicens, Josep
    Peraza-Nieves, Jorge
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3363 - 3371
  • [6] Age- and refraction-related changes in anterior segment anatomical structures measured by swept-source anterior segment OCT
    Xie, Xiaobin
    Corradetti, Giulia
    Song, Abe
    Pardeshi, Anmol
    Sultan, William
    Lee, Jong Yeon
    Yu, Fei
    Zhang, Lixia
    Chen, Shuang
    Chopra, Vikas
    Sadda, Srinivas R.
    Xu, Benjamin
    Huang, Alex S.
    PLOS ONE, 2020, 15 (10):
  • [7] Agreement between intraoperative anterior segment spectral-domain OCT and 2 swept-source OCT biometers
    Tana-Sanz, Pedro
    Ruiz-Santos, Maria
    Rodriguez-Carrillo, Maria Dolores
    Aguilar-Corcoles, Salvador
    Montes-Mico, Robert
    Tana-Rivero, Pedro
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (04) : 387 - 393
  • [8] Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT
    El-Fayoumi, Dina
    Bahgat, Nermeen
    Khafagy, Mohamed
    Hatata, Ragai
    Sabry, Dalia
    Allam, Ghada
    Kasem, Manal Ali
    Sadek, Sherin
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3583 - 3589
  • [9] Analysis of ocular inflammation in anterior chamber-involving uveitis using swept-source anterior segment OCT
    Baghdasaryan, Elmira
    Tepelus, Tudor C.
    Marion, Kenneth M.
    Huang, Jianyan
    Huang, Ping
    Sadda, SriniVas R.
    Lee, Olivia L.
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (08) : 1793 - 1801
  • [10] Intradevice Repeatability and Interdevice Agreement of Ocular Biometric Measurements: A Comparison of Two Swept-Source Anterior Segment OCT Devices
    Pardeshi, Anmol A.
    Song, Abe E.
    Lazkani, Naim
    Xie, Xiaobin
    Huang, Alex
    Xu, Benjamin Y.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (09): : 1 - 9