Disinfecting personal protective equipment with pulsed xenon ultraviolet as a risk mitigation strategy for health care workers

被引:34
作者
Jinadatha, Chetan [1 ,2 ]
Simmons, Sarah [3 ]
Dale, Charles [3 ]
Ganachari-Mallappa, Nagaraja [1 ]
Villamaria, Frank Charles [1 ]
Goulding, Nicole [4 ]
Tanner, Benjamin [4 ]
Stachowiak, Julie [3 ]
Stibich, Mark [3 ]
机构
[1] Cent Texas Vet Healthcare Syst, Dept Med, Temple, TX USA
[2] Texas A&M Hlth Sci Ctr, Coll Med, Dept Med, Bryan, TX USA
[3] Xenex Disinfect Serv LLC, San Antonio, TX 78209 USA
[4] Antimicrobial Test Labs, Round Rock, TX USA
关键词
Environmental disinfection; Ebola; Personal protective equipment; Doffing process; Outbreak control; Ultraviolet; CONTAMINATION; IMPACT;
D O I
10.1016/j.ajic.2015.01.013
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The doffing of personal protective equipment (PPE) after contamination with pathogens such as Ebola poses a risk to health care workers. Pulsed xenon ultraviolet (PX-UV) disinfection has been used to disinfect surfaces in hospital settings. This study examined the impact of PX-UV disinfection on an Ebola surrogate virus on glass carriers and PPE material to examine the potential benefits of using PX-UV to decontaminate PPE while worn, thereby reducing the pathogen load prior to doffing. Ultraviolet (UV) safety and coverage tests were also conducted. PX-UV exposure resulted in a significant reduction in viral load on glass carriers and PPE materials. Occupational Safety and Health Administration-defined UV exposure limits were not exceeded during PPE disinfection. Predoffing disinfection with PX-UV has potential as an additive measure to the doffing practice guidelines. The PX-UV disinfection should not be considered sterilization; all PPE should still be considered contaminated and doffed and disposed of according to established protocols. Copyright (C) 2015 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:412 / 414
页数:3
相关论文
共 14 条
[1]   A method for evaluating health care workers' personal protective equipment technique [J].
Beam, Elizabeth L. ;
Gibbs, Shawn G. ;
Boulter, Kathleen C. ;
Beckerdite, Dmarcia E. ;
Smith, Philip W. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2011, 39 (05) :415-420
[2]   Virus transfer from personal protective equipment to healthcare employees' skin and clothing [J].
Casanova, Lisa ;
Alfano-Sobsey, Edie ;
Rutala, William A. ;
Weber, David J. ;
Sobsey, Mark .
EMERGING INFECTIOUS DISEASES, 2008, 14 (08) :1291-1293
[3]  
Centers for Disease Control and Prevention, 2014, CRIT REC STAND OCC E
[4]  
Centers for Disease Control and Prevention, 2014, INT GUID ENV INF CON
[5]   Protecting Health Care Workers From Ebola: Personal Protective Equipment Is Critical but Is Not Enough [J].
Fischer, William A., II ;
Hynes, Noreen A. ;
Perl, Trish M. .
ANNALS OF INTERNAL MEDICINE, 2014, 161 (10) :753-U209
[6]   Clinical recognition and management of patients exposed to biological warfare agents [J].
Franz, DR ;
Jahrling, PB ;
Friedlander, AM ;
McClain, DJ ;
Hoover, DL ;
Bryne, WR ;
Pavlin, JA ;
Christopher, CW ;
Eitzen, EM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 278 (05) :399-411
[7]   Environment and body contamination: A comparison of two different removal methods in three types of personal protective clothing [J].
Guo, Y. P. ;
Li, Yi ;
Wong, Peony L. H. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2014, 42 (04) :E39-E45
[8]   Implementation and impact of ultraviolet environmental disinfection in an acute care setting [J].
Haas, Janet P. ;
Menz, Jonathan ;
Dusza, Stephen ;
Montecalvo, Marisa A. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2014, 42 (06) :586-590
[9]   Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus [J].
Jinadatha, Chetan ;
Quezada, Ricardo ;
Huber, Thomas W. ;
Williams, Jason B. ;
Zeber, John E. ;
Copeland, Laurel A. .
BMC INFECTIOUS DISEASES, 2014, 14
[10]   The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital [J].
Levin, Joanne ;
Riley, Linda S. ;
Parrish, Christine ;
English, Daniel ;
Ahn, Sehoon .
AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (08) :746-748