Technique for reducing variance in transducer array pulse-echo response

被引:0
|
作者
Zhou, SW [1 ]
Hossack, JA [1 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
来源
2004 IEEE Ultrasonics Symposium, Vols 1-3 | 2004年
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
There is widespread interest in finding low cost approaches for circumventing the problems caused by variations in transducer performance due to device material and geometry variations. In this work, deficiencies in the spectral response were estimated and used for the design of transmitter waveforms, or receive filters, that are programmed to compensate, at least in part, for the deficiencies. Fortunately, many modem 'high end' systems have programmable waveform generators in the transmit signal path and/or a versatile digital filter in the receive signal path. In the approach used here, power absorbed (Re(VI*)) is measured and used as a surrogate for a measure of pulse-echo response since it is arguably easier to measure. This procedure was investigated using a ID thickness mode transducer model that included two matching layers that were allowed to vary randomly over a range +/- 15% (approximately equivalent to approximately +/- 20 microns). In a simulation run involving 100 random designs, the spectral performance of the corrected transducer was observed to be much closer to desired spectral performance than that for the original uncorrected case. The mean deviation of the pulse-echo response measured over the 20 dB bandwidth was reduced to approximately one third of the value obtained without using the compensation approach. The -20 dB time domain pulse duration was also reduced by approximately 10%.
引用
收藏
页码:2211 / 2214
页数:4
相关论文
共 50 条
  • [1] Analysis of pulse-echo response based on linear MEMS ultrasonic transducer array
    2013, International Frequency Sensor Association, 46 Thorny Vineway, Toronto, ON M2J 4J2, Canada (151):
  • [2] PULSE-ECHO ULTRASONIC TRANSDUCER CHARACTERIZATION
    ERIKSON, K
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1979, 26 (01): : 1 - 1
  • [3] ANALYSIS OF A PULSE-ECHO ULTRASOUND TAPERED PHASED-ARRAY TRANSDUCER
    BENKESER, PJ
    GOFF, EF
    RICE, WO
    ULTRASONICS, 1987, 25 (06) : 376 - 376
  • [4] Optimization of pulse-echo array transducer system for identification of specified targets
    Pedersen, PC
    Wan, L
    ACOUSTICAL IMAGING, VOL 26, 2002, 26 : 373 - 380
  • [5] Characterization of an ultrasonic transducer in a pulse-echo setup
    Lopez-Sanchez, A
    Schmerr, LW
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 25A AND 25B, 2006, 820 : 900 - 907
  • [6] Plane Wave Pulse-Echo Ultrasound Diffraction Tomography with a Fixed Linear Transducer Array
    Schiffner, Martin F.
    Schmitz, Georg
    ACOUSTICAL IMAGING, VOL 31, 2012, 31 : 19 - 30
  • [7] Effect of acoustical properties of a lens on the pulse-echo response of a single element transducer
    Maréchal, P
    Levassort, F
    Félix, N
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 1651 - 1654
  • [8] PULSE-ECHO IMAGING USING A NONDIFFRACTING BEAM TRANSDUCER
    LU, JY
    GREENLEAF, JF
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (03): : 265 - 281
  • [9] Waveguide piezoelectric micromachined ultrasonic transducer array for short-range pulse-echo imaging
    Lu, Y.
    Tang, H.
    Wang, Q.
    Fung, S.
    Tsai, J. M.
    Daneman, M.
    Boser, B. E.
    Horsley, D. A.
    APPLIED PHYSICS LETTERS, 2015, 106 (19)
  • [10] ULTRASONIC PULSE-ECHO TECHNIQUE FOR VHF RANGE
    HEMPHILL, RB
    PENN, TC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (12): : 1809 - &