NON-INVASIVE FETAL BLOOD OXYGEN SATURATION MEASUREMENT BY MAGNETIC RESONANCE IMAGING IN SHEEP

被引:0
|
作者
Flouri, Dimitra [1 ,2 ]
Darby, RTJack [3 ]
Holman, Stacey L. [3 ]
Perumal, Sunthara R. [4 ]
David, Anna L. [5 ,6 ]
Morrison, Janna L. [3 ]
Melbourne, Andrew [1 ,2 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] UCL, Dept Med Phys & Biomed Engn, London, England
[3] Univ South Australia, Early Origins Adult Hlth Res Grp, UniSA Clin & Hlth Sci, Hlth & Biomed Innovat, Adelaide, SA, Australia
[4] South Australian Hlth & Med Res Inst, Preclin Imaging & Res Labs, Adelaide, SA, Australia
[5] UCL, Elizabeth Garrett Anderson Inst Womens Hlth, London, England
[6] Univ Coll London Hosp, NIHR Biomed Res Ctr, London, England
基金
英国惠康基金;
关键词
D O I
暂无
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
S7.5
引用
收藏
页码:E18 / E18
页数:1
相关论文
共 50 条
  • [21] In Vivo MRI Measurement of Fetal Blood Oxygen Saturation in Cardiac Ventricles of Fetal Sheep: A Feasibility Study
    Wedegaertner, Ulrike
    Kooijman, Hendrik
    Yamamura, Jin
    Frisch, Michael
    Weber, Christoph
    Buchert, Ralph
    Huff, Anna
    Hecher, Kurt
    Adam, Gerhard
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 32 - 41
  • [22] Non-invasive pH-weighted magnetic resonance imaging
    Dai, Z.
    Xiao, G.
    Shen, Z.
    Wang, L.
    Sun, P. Z.
    Wu, R.
    EUROPEAN JOURNAL OF NEUROLOGY, 2012, 19 : 404 - 404
  • [23] Non-invasive diagnosis of chylopericardium by cardiac magnetic resonance imaging
    Luaces, Maria
    Perales, Isabel
    Nunez-Gil, Ivan J.
    Cabezudo, Jorge
    EUROPEAN HEART JOURNAL, 2010, 31 (07) : 823 - 823
  • [24] Non-invasive measurement and validation of tissue oxygen saturation covered with overlying tissues
    Jenchung Chien
    Betau Hwang
    ProgressinNaturalScience, 2008, (09) : 1083 - 1088
  • [25] Non-invasive measurement and validation of tissue oxygen saturation covered with overlying tissues
    Teng, Yichao
    Ding, Haishu
    Huang, Lan
    Li, Yue
    Shan, Quanzhong
    Ye, Datian
    Ding, Haiyan
    Chien, Jenchung
    Hwang, Betau
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2008, 18 (09) : 1083 - 1088
  • [26] Non-invasive measurement of oxygen saturation by pulse oxymetry in assessment and monitoring of bronchiolitis
    Pin, I
    Pilenko, C
    Bost, M
    ARCHIVES DE PEDIATRIE, 2001, 8 : 114S - 116S
  • [27] Magnetic resonance imaging measurement of placental perfusion and oxygen saturation in early-onset fetal growth restriction
    Aughwane, R.
    Mufti, N.
    Flouri, D.
    Maksym, K.
    Spencer, R.
    Sokolska, M.
    Kendall, G.
    Atkinson, D.
    Bainbridge, A.
    Deprest, J.
    Vercauteren, T.
    Ourselin, S.
    David, A. L.
    Melbourne, A.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2021, 128 (02) : 337 - 345
  • [28] Non-invasive measurement of lipid and water in single wheat grains using magnetic resonance imaging
    Chua, HS
    Mantle, MD
    Haigh, AD
    Thompson, F
    Gibson, AAP
    Gladden, LF
    2004 HIGH FREQUENCY POSTGRADUATE STUDENT COLLOQUIUM, 2004, : 199 - 204
  • [29] Non-invasive measurement of liver iron concentration by magnetic resonance imaging and its clinical usefulness
    Alustiza, Jose M.
    Castiella, Agustin
    Zapata, Eva
    Urreta, Iratxe
    Salvador, Emma
    Emparanza, Jose I.
    ARCHIVES OF MEDICAL SCIENCE, 2023, 19 (03) : 784 - 791
  • [30] The Application of Non-invasive Oxygen Saturation Sensor to Evaluate Blood Flow in Human
    Lu, Yi-Te
    Hsieh, Kuen-Chang
    Kao, Ming-Feng
    Chen, Yu-Ywan
    Chung, Chiung-Chu
    Lu, Hsueh-Kuan
    MEDICAL BIOMETRICS, PROCEEDINGS, 2010, 6165 : 241 - +