First measurements of a scintillator based fast-ion loss detector near the ASDEX Upgrade divertor

被引:12
|
作者
Gonzalez-Martin, J. [1 ,2 ]
Ayllon-Guerola, J. [1 ,2 ]
Garcia-Munoz, M. [2 ,3 ]
Herrmann, A. [4 ]
Leitenstern, P. [4 ]
De Marne, P. [4 ]
Zoletnik, S. [5 ]
Kovacsik, A. [5 ]
Galdon-Quiroga, J. [2 ,3 ]
Rivero-Rodriguez, J. [1 ,2 ]
Rodriguez-Ramos, M. [2 ,3 ]
Sanchis-Sanchez, L. [2 ,3 ]
Dominguez, J. [1 ]
机构
[1] Univ Seville, Dept Mech & Mfg Engn, C Camino Descubrimientos S-N, Seville, Spain
[2] Univ Seville, CNA, CSIC, Seville, Spain
[3] Univ Seville, Dept Atom Mol & Nucl Phys, Fac Phys, E-41012 Seville, Spain
[4] Max Planck Inst Plasma Phys, Garching, Germany
[5] Wigner RCP, Budapest, Hungary
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
D O I
10.1063/1.5038968
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new reciprocating scintillator based fast-ion loss detector has been installed a few centimeters above the outer divertor of the ASDEX Upgrade tokamak and between two of its lower Edge Localized Modes (ELM) mitigation coils. The detector head containing the scintillator screen, Faraday cup, calibration lamp, and collimator systems are installed on a motorized reciprocating system that can adjust its position via remote control in between plasma discharges. Orbit simulations are used to optimize the detector geometry and velocity-space coverage. The scintillator image is transferred to the light acquisition systems outside of the vacuum via a lens relay (embedded in a 3D-printed titanium holder) and an in-vacuum image guide. A charge coupled device camera, for high velocity space resolution, and an 8 X 8 channel avalanche photo diode camera, for high temporal resolution (up to 2 MHz), are used as light acquisition systems. Initial results showing velocity-space of neutral beam injection prompt losses and fast-ion losses induced by a (2, 1) neoclassical tearing mode are presented.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] First measurements of a scintillator-based fast-ion loss detector in reversed Ip/Bt at the ASDEX Upgrade tokamak
    Hidalgo-Salaverri, J.
    Rueda-Rueda, J.
    Galdon-Quiroga, J.
    Cano-Megias, P.
    Viezzer, E.
    Garcia-Dominguez, J.
    Silvagni, D.
    Videla-Trevin, M.
    Oyola, P.
    Ayllon-Guerola, J.
    Garcia-Munoz, M.
    Happel, T.
    FUSION ENGINEERING AND DESIGN, 2023, 193
  • [2] First measurements of a magnetically driven fast-ion loss detector on ASDEX Upgrade
    Gonzalez-Martin, J.
    Garcia-Munoz, M.
    Herrmann, A.
    Ayllon-Guerola, J.
    Gaidon-Quiroga, J.
    Kovacsik, A.
    Leitenstern, P.
    Lunt, T.
    Rivero-Rodriguez, J. F.
    Sieglin, B.
    Zoletnik, S.
    Dominguez, J.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [3] Scintillator based detector for fast-ion losses induced by magnetohydrodynamic instabilities in the ASDEX upgrade tokamak
    Garcia-Munoz, M.
    Fahrbach, H. -U.
    Zohm, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (05):
  • [4] First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak
    Rodriguez-Ramos, M.
    Garcia-Munoz, M.
    Jimenez-Ramos, M. C.
    Garcia-Lopez, J.
    Galdon-Quiroga, J.
    Sanchis-Sanchez, L.
    Ayllon-Guerola, J.
    Faitsch, M.
    Gonzalez-Martin, J.
    Hermann, A.
    de Marne, P.
    Rivero-Rodriguez, J. F.
    Sieglin, B.
    Snicker, A.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2017, 59 (10)
  • [5] Upgrade and absolute calibration of the JET scintillator-based fast-ion loss detector
    Rivero-Rodriguez, J. F.
    Von Thun, C. Perez
    Garcia-Munoz, M.
    Beaumont, P.
    Kiptily, V.
    Garcia-Lopez, J.
    Goloborodko, V.
    Jimenez-Ramos, M. C.
    Rodriguez-Ramos, M.
    Schoepf, K.
    Yavorskij, V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (04):
  • [6] Fast-ion D-alpha measurements at ASDEX Upgrade
    Geiger, B.
    Garcia-Munoz, M.
    Heidbrink, W. W.
    McDermott, R. M.
    Tardini, G.
    Dux, R.
    Fischer, R.
    Igochine, V.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2011, 53 (06)
  • [7] Consistency between real and synthetic fast-ion measurements at ASDEX Upgrade
    Rasmussen, J.
    Nielsen, S. K.
    Stejner, M.
    Geiger, B.
    Salewski, M.
    Jacobsen, A. S.
    Korsholm, S. B.
    Leipold, F.
    Michelsen, P. K.
    Moseev, D.
    Schubert, M.
    Stober, J.
    Tardini, G.
    Wagner, D.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2015, 57 (07)
  • [8] Thermo-mechanical limits of a magnetically driven fast-ion loss detector in the ASDEX Upgrade tokamak
    Hidalgo-Salaverri, J.
    Gonzalez-Martin, J.
    Ayllon-Guerola, J.
    Garcia-Munoz, M.
    Sieglin, B.
    Galdon-Quiroga, J.
    Silvagni, D.
    Viezzer, E.
    Rueda-Rueda, J.
    Lunt, T.
    Herrmann, A.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (02):
  • [9] A fast feedback controlled magnetic drive for the ASDEX Upgrade fast-ion loss detectors
    Ayllon-Guerola, J.
    Gonzalez-Martin, J.
    Garcia-Munoz, M.
    Rivero-Rodriguez, J.
    Herrmann, A.
    Vorbrugg, S.
    Leitenstern, P.
    Zoletnik, S.
    Galdon, J.
    Garcia-Lopez, J.
    Rodriguez-Ramos, M.
    Sanchis-Sanchez, L.
    Dominguez, A. D.
    Kocan, M.
    Gunn, J. P.
    Garcia-Vallejo, D.
    Dominguez, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [10] Self-adaptive diagnostic of radial fast-ion loss measurements on the ASDEX Upgrade tokamak (invited)
    Gonzalez-Martin, J.
    Garcia-Munoz, M.
    Sieglin, B.
    Herrmann, A.
    Lunt, T.
    Ayllon-Guerola, J.
    Galdon-Quiroga, J.
    Hidalgo-Salaverri, J.
    Kovacsik, A.
    Rivero-Rodriguez, J. F.
    Sanchis, L.
    Silvagni, D.
    Zoletnik, S.
    Dominguez, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):