Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method

被引:11
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Iwatsuki Ward, Iwatsuki, Saitama 3390077, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
BIOENGINEERING-BASEL | 2019年 / 6卷 / 04期
关键词
3D model; Biomechanics; Finite element analysis; Finite element method; Prosthetic socket; Transfemoral residuum;
D O I
10.3390/bioengineering6040098
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, we estimated and validated the pressure distribution profile between the residuum and two types of prosthetic sockets for transfemoral amputees by utilizing a finite element analysis. Correct shaping of the socket for an appropriate load distribution is a critical process in the design of lower-limb prosthesis sockets. The pressure distribution profile provides an understanding of the relationship between the socket design and the level of subject comfortability. Estimating the pressure profile is important, as it helps improve the prosthesis through an evaluation of the socket design before it undergoes the fabrication process. This study focused on utilizing a magnetic resonance imaging (MRI)-based three-dimensional (3D) model inside a predetermined finite element simulation. The simulation was predetermined by mimicking the actual socket-fitting environment. The results showed that the potential MRI-based 3D model simulation could be used as an estimation tool for a pressure distribution profile due to the high correlation coefficient value (R-2 > 0.8) calculated when the pressure profiles were compared to the experiment data. The simulation also showed that the pressure distribution in the proximal area was higher (similar to 30%) than in the distal area of the prosthetic socket for every subject. The results of this study will be of tremendous interest for fabricators through the use of a finite element model as an alternative method for the prefabrication and evaluation of prosthetic sockets. In future prosthetic socket fabrications, less intervention will be required in the development of a socket, and the participation of the subject in the socket-fitting session will not be necessary. The results suggest that this study will contribute to expanding the development of an overall prefabrication evaluation system to allow healthcare providers and engineers to simulate the fit and comfort of transfemoral prosthetics.
引用
收藏
页数:12
相关论文
共 50 条
[21]   Evaluation of hydraulic fracturing pressure in a porous medium by using the finite element method [J].
Nouri, A ;
Panah, AK ;
Pak, A ;
Vaziri, H ;
Islam, MR .
ENERGY SOURCES, 2002, 24 (08) :715-724
[22]   A three-dimensional finite element model of the transibial residual limb and prosthetic socket to predict skin temperatures [J].
Peery, Jeffrey T. ;
Klute, Glenn K. ;
Blevins, Joanna J. ;
Ledoux, William R. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (03) :336-343
[23]   Finite element analysis and mathematical characterization of contact pressure distribution in bolted joints [J].
Cao, Jianbin ;
Zhang, Zhousuo .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (10) :4715-4725
[24]   Finite element analysis and mathematical characterization of contact pressure distribution in bolted joints [J].
Jianbin Cao ;
Zhousuo Zhang .
Journal of Mechanical Science and Technology, 2019, 33 :4715-4725
[25]   The Effect of the Length and Distribution of Implants for Fixed Prosthetic Reconstructions in the Atrophic Posterior Maxilla: A Finite Element Analysis [J].
Cenkoglu, Brunilda Gashi ;
Balcioglu, Nilufer Bolukbasi ;
Ozdemir, Tayfun ;
Mijiritsky, Eitan .
MATERIALS, 2019, 12 (16)
[26]   Finite element analysis and experimental validation of polycentric prosthetic knee [J].
Mohanty, Rajesh Kumar ;
Mohanty, Ramesh Chandra ;
Sabut, Sukanta Kumar .
MATERIALS TODAY-PROCEEDINGS, 2022, 63 :207-214
[27]   A Method for Obtaining a Three-Dimensional Geometric Model of Dental Implants for Analysis via the Finite Element Method [J].
Silva, Guilherme Carvalho ;
Pereira Cornacchia, Tulimar Machado ;
de Las Casas, Estevam Barbosa ;
de Magalhaes, Claudia Silami ;
Moreira, Allyson Nogueira .
IMPLANT DENTISTRY, 2013, 22 (03) :309-314
[28]   Effect of Prosthetic Material and Support Type on Stress Distribution of Fixed Partial Dentures: A Finite Element Study [J].
Eric, Jelena ;
Bjelovic, Ljiljana ;
Radovic, Igor ;
Krunic, Jelena ;
Milic-Lemic, Aleksandra ;
Gupta, Nidhi ;
Ali, Kamran .
CERAMICS-SWITZERLAND, 2024, 7 (03) :1204-1217
[29]   Discrete Element Analysis for Characterizing the Patellofemoral Pressure Distribution: Model Evaluation [J].
Elias, John J. ;
Saranathan, Archana .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (08)
[30]   Effects of Prosthetic Material and Framework Design on Stress Distribution in Dental Implants and Peripheral Bone: A Three-Dimensional Finite Element Analysis [J].
Arinc, Hakan .
MEDICAL SCIENCE MONITOR, 2018, 24 :4279-4287