Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method

被引:9
|
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Iwatsuki Ward, Iwatsuki, Saitama 3390077, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
BIOENGINEERING-BASEL | 2019年 / 6卷 / 04期
关键词
3D model; Biomechanics; Finite element analysis; Finite element method; Prosthetic socket; Transfemoral residuum;
D O I
10.3390/bioengineering6040098
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, we estimated and validated the pressure distribution profile between the residuum and two types of prosthetic sockets for transfemoral amputees by utilizing a finite element analysis. Correct shaping of the socket for an appropriate load distribution is a critical process in the design of lower-limb prosthesis sockets. The pressure distribution profile provides an understanding of the relationship between the socket design and the level of subject comfortability. Estimating the pressure profile is important, as it helps improve the prosthesis through an evaluation of the socket design before it undergoes the fabrication process. This study focused on utilizing a magnetic resonance imaging (MRI)-based three-dimensional (3D) model inside a predetermined finite element simulation. The simulation was predetermined by mimicking the actual socket-fitting environment. The results showed that the potential MRI-based 3D model simulation could be used as an estimation tool for a pressure distribution profile due to the high correlation coefficient value (R-2 > 0.8) calculated when the pressure profiles were compared to the experiment data. The simulation also showed that the pressure distribution in the proximal area was higher (similar to 30%) than in the distal area of the prosthetic socket for every subject. The results of this study will be of tremendous interest for fabricators through the use of a finite element model as an alternative method for the prefabrication and evaluation of prosthetic sockets. In future prosthetic socket fabrications, less intervention will be required in the development of a socket, and the participation of the subject in the socket-fitting session will not be necessary. The results suggest that this study will contribute to expanding the development of an overall prefabrication evaluation system to allow healthcare providers and engineers to simulate the fit and comfort of transfemoral prosthetics.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Evaluation of the Effects of Geometrical Changes in Prosthetic Socket Towards Transfemoral Residuum via Finite Element Method
    Jamaludin, Mohd Syahmi
    Hanafusa, Akihiko
    Yamamoto, Shin-Ichirou
    Agarie, Yukio
    Otsuka, Hiroshi
    Onishi, Kengo
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 314 - 319
  • [2] Development of an Evaluation System for Magnetic Resonance Imaging Based Three-Dimensional Modeling of a Transfemoral Prosthetic Socket Using Finite Elements
    Jamaludin, Mohd Syahmi
    Hanafusa, Akihiko
    Shinichirou, Yamamoto
    Agarie, Yukio
    Otsuka, Hiroshi
    Ohnishi, Kengo
    APPLIED SCIENCES-BASEL, 2019, 9 (18):
  • [3] Parametric optimization and design validation based on finite element analysis of hybrid socket adapter for transfemoral prosthetic knee
    Kumar, Neelesh
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (05) : 363 - 368
  • [4] Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket
    SilverThorn, MB
    Childress, DS
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1997, 34 (02) : 171 - 186
  • [5] Analysis of Pressure Distribution of the Bolted Joints Based on the Finite Element Method
    Wang, Sheng-ao
    Zhu, Min
    Wu, Fei
    Liang, Tian-xi
    Shao, Zhao-qun
    Liu, Yi-long
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2023, 23 (02) : 586 - 598
  • [6] Analysis of Pressure Distribution of the Bolted Joints Based on the Finite Element Method
    Sheng-ao Wang
    Min Zhu
    Fei Wu
    Tian-xi Liang
    Zhao-qun Shao
    Yi-long Liu
    International Journal of Steel Structures, 2023, 23 : 586 - 598
  • [7] Key considerations for finite element modelling of the residuum-prosthetic socket interface
    Steer, J. W.
    Worsley, P. R.
    Browne, M.
    Dickinson, Alex
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2021, 45 (02) : 138 - 146
  • [8] Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket
    Lee, WCC
    Zhang, M
    Jia, XH
    Cheung, JTM
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (08) : 655 - 662
  • [9] Socket Material and Coefficient of Friction Influence on Residuum-Prosthesis Interface Stresses for a Transfemoral Amputee: A Finite Element Analysis
    Leao Rodrigues, Alina de Souza
    Da Gama, A. E. F.
    XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 1495 - 1502
  • [10] Buckling analysis of prosthetic pylon tubes using finite element method
    Macaspac, Hannah Erika D.
    Magdaluyo, Eduardo R.
    ENGINEERING RESEARCH EXPRESS, 2021, 3 (03):