Accuracy of dental implant placement via dynamic navigation or the freehand method: A split-mouth randomized controlled clinical trial

被引:122
|
作者
Aydemir, Ceyda Aktolun [1 ]
Arisan, Volkan [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Oral Implantol, TR-34093 Istanbul, Turkey
关键词
clinical trial; computer-assisted; computers; dental implants; dimensional measurement accuracy; surgery; tomography; COMPUTER-TECHNOLOGY APPLICATIONS; MENTAL NAVIGATION; SURGERY; DENTISTRY; SYSTEMS; CT;
D O I
10.1111/clr.13563
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this split-mouth randomized controlled clinical trial was to compare the deviations of planned and placed implants placed by the assistance of a micron tracker-based dynamic navigation device or freehand methods. Material and methods A thermoplastic fiducial marker was adapted on the anterior teeth, and cone-beam computerized tomography was used for imaging. A minimum of one implant was planned for each side of the posterior maxilla, and the dynamic navigation device or freehand method was randomly used for surgical insertion. Deviations were measured by matching the planning data with a final CBCT image. Linear deviations (mm) between the planned and placed implants were the primary outcome. The results were analysed by generalized linear mixed models (p < .05). (NCT03471208). Results A total of 92 implants were placed to 32 volunteers, and 86 implants were included in the final analysis. For the linear deviations, mean of differences (Delta) was 0.72mm (Standard deviation (SD): 0.26); (95% Confidence interval (CI): 0.39-1.02) in the shoulder of the implants (p < .001) and 0.69mm (SD: 0.36); (95% CI: 0.19-1.19) in the tip of the implants (p < .001). For the angular deviations, Delta was 5.33 degrees (SD: 1.63); (95% CI: 7.17-3.48); (p < .001). Conclusions The navigation technique can be used to transfer virtual implant planning to the patient's jaw with increased accuracy.
引用
收藏
页码:255 / 263
页数:9
相关论文
共 50 条
  • [21] Epicrestal and subcrestal placement of platform-switched implants: 18month-result of a randomized, controlled, split-mouth, prospective clinical trial
    Froum, Stuart J.
    Cho, Sang-Choon
    Suzuki, Takanori
    Yu, Paul
    Corby, Patricia
    Khouly, Ismael
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (04) : 353 - 366
  • [22] A split-mouth randomized clinical trial of conventional and heavy flowable composites in class II restorations
    Gomes Torres, Carlos Rocha
    Chagas Rego, Heleine Maria
    Costa Perote, Leticia C. C.
    Santos, Luciana F. Thives F.
    Beber Kamozaki, Maria Beatriz
    Gutierrez, Natalia Cortez
    Di Nicolo, Rebeca
    Borges, Alessandra Buehler
    JOURNAL OF DENTISTRY, 2014, 42 (07) : 793 - 799
  • [23] Accuracy of intentionally tilted implant placement in the maxilla using dynamic navigation: a retrospective clinical analysis
    Meng, T.
    Zhang, X.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 51 (04) : 552 - 557
  • [24] Does Implant Design Affect Implant Primary Stability? A Resonance Frequency Analysis-Based Randomized Split-Mouth Clinical Trial
    Gehrke, Sergio Alexandre
    da Silva Neto, Ulisses Tavares
    Del Fabbro, Massimo
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : E281 - E286
  • [25] Comparing patient-reported outcomes and experiences among static, dynamic computer-aided, and conventional freehand dental implant placement: A randomized clinical trial
    Engkawong, Sunida
    Mattheos, Nikos
    Pisarnturakit, Pagaporn Pantumwadee
    Pimkhaokham, Atiphan
    Subbalekha, Keskanya
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (05) : 660 - 670
  • [26] ENAP vs LANAP: assessment of revascularization using ultrasound Doppler flowmetry-a split-mouth randomized controlled clinical trial
    Sameera, Shaik
    Kumar, Pavuluri Aravind
    Nagasri, Medandrao
    Indeevar, Pantareddy
    Raviraj, Kalapala
    LASERS IN MEDICAL SCIENCE, 2018, 33 (06) : 1181 - 1188
  • [27] For Indirect Orthodontic Attachment Placement, Adding a Custom Composite Resin Base Is Not Beneficial: A Split-Mouth Randomized Clinical Trial
    Hassan, Mohamed S.
    Abdelsayed, Fatma A.
    Abdelghany, Amany H.
    Morse, Zac
    Aboulfotouh, Mai H.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022
  • [28] Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial
    Edelmann, Cornelia
    Wetzel, Martin
    Knipper, Anne
    Luthardt, Ralph G.
    Schnutenhaus, Sigmar
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [29] Comparison of the accuracy of two different dynamic navigation system registration methods for dental implant placement: A retrospective study
    Ma, Feifei
    Sun, Feng
    Wei, Tai
    Ma, Yu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (03) : 352 - 360
  • [30] Accuracy of dynamic navigation compared to static surgical guide for dental implant placement
    Dong Wu
    Lin Zhou
    Jin Yang
    Bao Zhang
    Yanjun Lin
    Jiang Chen
    Wenxiu Huang
    Yonghui Chen
    International Journal of Implant Dentistry, 6