Analysis of partial volume correction on quantification and regional heterogeneity in cardiac PET

被引:2
|
作者
Turco, A. [1 ]
Nuyts, J. [1 ]
Duchenne, J. [2 ]
Gheysens, O. [1 ,3 ]
Voigt, J. U. [2 ,4 ]
Claus, P. [2 ]
Vunckx, K. [1 ]
机构
[1] Univ Leuven, Med Imaging Res Ctr,Dept Imaging,Pathology, Nucl Med,Mol imaging,MIRC,KU Leuven, B-3000 Leuven, Belgium
[2] Univ Leuven, Med Imaging Res Ctr,Dept Cardiovascular Sciences, Cardiology,MIRC,KU Leuven, B-3000 Leuven, Belgium
[3] Univ Hospitals Leuven, Dept Nucl Med, B-3000 Leuven, Belgium
[4] Univ Hospitals Leuven, Dept Cardiovascular Dis, B-3000 Leuven, Belgium
关键词
Cardiac PET; system resolution; partial volume correction; quantification; RECONSTRUCTION;
D O I
10.1007/s12350-016-0773-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The partial volume correction (PVC) of cardiac PET datasets using anatomical side information during reconstruction is appealing but not straightforward. Other techniques, which do not make use of additional anatomical information, could be equally effective in improving the reconstructed myocardial activity. Methods Resolution modeling in combination with different noise suppressing priors was evaluated as a means to perform PVC. Anatomical priors based on a high-resolution CT are compared to non-anatomical, edge-preserving priors (relative difference and total variation prior). The study is conducted on ex vivo datasets from ovine hearts. A simulation study additionally clarifies the relationship between prior effectiveness and myocardial wall thickness. Results Simple resolution modeling during data reconstruction resulted in over- and underestimation of activity, which hampers the absolute left ventricular quantification when compared to the ground truth. Both the edge-preserving and the anatomy-based PVC techniques improve the absolute quantification, with comparable results (Student t-test, P = .17). The relative tracer distribution was preserved with any reconstruction technique (repeated ANOVA, P = .98). Conclusions The use of edge-preserving priors emerged as optimal choice for quantification of tracer uptake in the left ventricular wall of the available datasets. Anatomical priors visually outperformed edge-preserving priors when the thinnest structures were of interest.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 50 条
  • [31] Application of Partial Volume Effect Correction and 4D PET in the Quantification of FDG Avid Lung Lesions
    Salavati, Ali
    Borofsky, Samuel
    Boon-Keng, Teo K.
    Houshmand, Sina
    Khiewvan, Benjapa
    Saboury, Babak
    Codreanu, Ion
    Torigian, Drew A.
    Zaidi, Habib
    Alavi, Abass
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (01) : 140 - 148
  • [32] Partial Volume Correction for Noninvasive PET Image-Derived Simplified Kinetic Analysis
    Sattarivand, M.
    Caldwell, C.
    Poon, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [33] 3D Model-based partial volume correction for cardiac PET imaging in mice
    Dumouchel, Tyler
    deKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [34] Comparison of three methods of partial volume correction in dynamic PET cardiac imaging - A phantom and a pig study
    Le Meunier, Ludovic
    Hadi, Mohiuddin
    de Silva, Ranil
    Carson, Joann M.
    Dieckmann, William
    Bacharach, Stephen L.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2359 - 2363
  • [35] Study of the quantification of FBPSPECT images with a correction for partial volume effects
    Koole, M
    Van de Walle, R
    Van Laere, K
    D'Asseler, Y
    Vandenberghe, S
    Lemahieu, I
    Dierckx, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 69 - 73
  • [36] A recovery coefficient method for partial volume correction of PET images
    Shyam M. Srinivas
    Thiruvenkatasamy Dhurairaj
    Sandip Basu
    Gonca Bural
    Suleman Surti
    Abass Alavi
    Annals of Nuclear Medicine, 2009, 23 : 341 - 348
  • [37] Correction for partial volume averaging of noisy PET data.
    Slifstein, M
    Mawlawi, O
    Laruelle, M
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 117P - 117P
  • [38] Reproducibility of radiomics features in partial volume correction of PET images
    Azimi, Mohammad-Saber
    Kamali-Asl, Alireza
    Ay, Mohammad-Reza
    Hosseini, Mahboube Sadat
    Khorshidi, Fatemeh
    Arabi, Hossein
    Rahmim, Arman
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [39] Partial volume correction in brain PET-FDG studies
    Prieto, E.
    Marti-Climent, J. M.
    Gomez-Fernandez, M.
    Lecumberri, P.
    Bustince, H.
    Arbizu, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S148 - S148
  • [40] Partial volume correction strategies for quantitative FDG PET in oncology
    Hoetjes, Nikie J.
    van Velden, Floris H. P.
    Hoekstra, Otto S.
    Hoekstra, Corneline J.
    Krak, Nanda C.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) : 1679 - 1687