Analysis of partial volume correction on quantification and regional heterogeneity in cardiac PET

被引:2
|
作者
Turco, A. [1 ]
Nuyts, J. [1 ]
Duchenne, J. [2 ]
Gheysens, O. [1 ,3 ]
Voigt, J. U. [2 ,4 ]
Claus, P. [2 ]
Vunckx, K. [1 ]
机构
[1] Univ Leuven, Med Imaging Res Ctr,Dept Imaging,Pathology, Nucl Med,Mol imaging,MIRC,KU Leuven, B-3000 Leuven, Belgium
[2] Univ Leuven, Med Imaging Res Ctr,Dept Cardiovascular Sciences, Cardiology,MIRC,KU Leuven, B-3000 Leuven, Belgium
[3] Univ Hospitals Leuven, Dept Nucl Med, B-3000 Leuven, Belgium
[4] Univ Hospitals Leuven, Dept Cardiovascular Dis, B-3000 Leuven, Belgium
关键词
Cardiac PET; system resolution; partial volume correction; quantification; RECONSTRUCTION;
D O I
10.1007/s12350-016-0773-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The partial volume correction (PVC) of cardiac PET datasets using anatomical side information during reconstruction is appealing but not straightforward. Other techniques, which do not make use of additional anatomical information, could be equally effective in improving the reconstructed myocardial activity. Methods Resolution modeling in combination with different noise suppressing priors was evaluated as a means to perform PVC. Anatomical priors based on a high-resolution CT are compared to non-anatomical, edge-preserving priors (relative difference and total variation prior). The study is conducted on ex vivo datasets from ovine hearts. A simulation study additionally clarifies the relationship between prior effectiveness and myocardial wall thickness. Results Simple resolution modeling during data reconstruction resulted in over- and underestimation of activity, which hampers the absolute left ventricular quantification when compared to the ground truth. Both the edge-preserving and the anatomy-based PVC techniques improve the absolute quantification, with comparable results (Student t-test, P = .17). The relative tracer distribution was preserved with any reconstruction technique (repeated ANOVA, P = .98). Conclusions The use of edge-preserving priors emerged as optimal choice for quantification of tracer uptake in the left ventricular wall of the available datasets. Anatomical priors visually outperformed edge-preserving priors when the thinnest structures were of interest.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 50 条
  • [21] Partial volume correction for improved PET quantification in 18F-NaF imaging of atherosclerotic plaques
    Cal-Gonzalez, J.
    Li, X.
    Heber, D.
    Rausch, I.
    Moore, S. C.
    Schaefers, K.
    Hacker, M.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S495 - S495
  • [22] Partial volume correction for improved PET quantification in 18F-NaF imaging of atherosclerotic plaques
    Jacobo Cal-Gonzalez
    Xiang Li
    Daniel Heber
    Ivo Rausch
    Stephen C. Moore
    Klaus Schäfers
    Marcus Hacker
    Thomas Beyer
    Journal of Nuclear Cardiology, 2018, 25 : 1742 - 1756
  • [23] Correction of partial volume effect in the projections in PET studies
    Guillette, Nicolas
    Sarrhini, Otman
    Lecomte, Roger
    Bentourkia, M'hamed
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3541 - 3543
  • [24] Correction for partial volume effects in PET: Principle and validation
    Rousset, OG
    Ma, YL
    Evans, AC
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 904 - 911
  • [25] Extravascular density model for PET partial volume correction
    Wassenaar, Richard W.
    deKemp, Robert A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1809 - 1813
  • [26] Impact of Partial Volume Effect On PET Image: Quantification Aspect
    Villeneuve, R.
    Risso, R.
    Garnier, N.
    Paulmier, B.
    Serrano, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Partial volume compensation for dynamic cardiac PET imaging
    Du, Yong
    Higuchi, Takahiro
    Madar, Igal
    Fung, George
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [28] MRI-BASED CORRECTION FOR PET PARTIAL VOLUME EFFECTS IN THE PRESENCE OF HETEROGENEITY IN GRAY-MATTER RADIOACTIVITY
    MELTZER, CC
    ZUBIETA, JK
    LINKS, JM
    BRAKEMAN, P
    STUMPF, MJ
    FROST, JJ
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P197 - P197
  • [29] Design and implementation of an automated partial volume correction in PET: Application to dopamine receptor quantification in the normal human striatum
    Rousset, Olivier G.
    Collins, D. Louis
    Rahmim, Arman
    Wong, Dean F.
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (07) : 1097 - 1106
  • [30] Application of Partial Volume Effect Correction and 4D PET in the Quantification of FDG Avid Lung Lesions
    Ali Salavati
    Samuel Borofsky
    Teo K. Boon-Keng
    Sina Houshmand
    Benjapa Khiewvan
    Babak Saboury
    Ion Codreanu
    Drew A. Torigian
    Habib Zaidi
    Abass Alavi
    Molecular Imaging and Biology, 2015, 17 : 140 - 148