Optimization of MALDI-TOF MS detection for enhanced sensitivity of affinity-captured proteins spanning a 100 kDa mass range

被引:26
作者
Gatlin-Bunai, Christine L. [1 ]
Cazares, Lisa H.
Cooke, William E.
Semmes, Oliver J.
Malyarenko, Dariya I.
机构
[1] Coll William & Mary, Dept Appl Sci & Phys, Williamsburg, VA 23185 USA
[2] Eastern Virginia Med Sch, Dept Microbiol & Mol Cell Biol, Ctr Biomed Proteom, Norfolk, VA 23501 USA
关键词
mass spectrometry; proteomics; magnetic beads; affinity capture; broad mass range; enhanced sensitivity; protein profiling;
D O I
10.1021/pr0703526
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Analysis of complex biological samples by MALDI-TOF mass spectrometry has been generally limited to the detection of low-mass protein (or protein fragment) peaks. We have extended the mass range of MALDI-TOF high-sensitivity detection by an order of magnitude through the combined optimization of instrument parameters, data processing, and sample preparation procedures for affinity capture. WCX, C3, and IMAC magnetic beads were determined to be complementary and most favorable for broad mass range protein profiling. Key instrument parameters for extending mass range included adjustment of the ADC offset and preamplifier filter values of the TOF detector. Data processing was improved by a combination of constant and quadratic down-sampling, preceded by exponential baseline subtraction, to increase sensitivity of signal peaks. This enhancement in broad mass range detection of protein signals will be of direct benefit in MS expression profiling studies requiring full linear range mass detection.
引用
收藏
页码:4517 / 4524
页数:8
相关论文
共 38 条
[1]  
Adam BL, 2002, CANCER RES, V62, P3609
[2]  
Bahr U, 1997, J MASS SPECTROM, V32, P1111, DOI 10.1002/(SICI)1096-9888(199711)32:10<1111::AID-JMS567>3.0.CO
[3]  
2-Y
[4]   Standardized approach to proteome profiling of human serum based on magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Baumann, S ;
Ceglarek, U ;
Fiedler, GM ;
Lembcke, J ;
Leichtle, A ;
Thiery, J .
CLINICAL CHEMISTRY, 2005, 51 (06) :973-980
[5]  
Cazares LH, 2002, CLIN CANCER RES, V8, P2541
[6]   Profiling and imaging proteins in tissue sections by MS [J].
Chaurand, P ;
Schwartz, SA ;
Caprioli, RM .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :86A-93A
[7]  
Conrads Thomas P, 2004, Mol Diagn, V8, P77, DOI 10.2165/00066982-200408020-00001
[8]  
COTTER RJ, 1997, TIME FLIGHT MASS SPE, P326
[9]   Top-down proteomics for rapid identification of intact microorganisms [J].
Demirev, PA ;
Feldman, AB ;
Kowalski, P ;
Lin, JS .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7455-7461
[10]   Characterization of intact microorganisms by MALDI mass spectrometry [J].
Fenselau, C ;
Demirev, PA .
MASS SPECTROMETRY REVIEWS, 2001, 20 (04) :157-171