Relationship between meibomian gland loss in infrared meibography and meibum quality in dry eye patients

被引:7
作者
Ha, Minji [1 ,2 ]
Oh, Si-Eun [1 ]
Whang, Woong-Joo [1 ,2 ]
Na, Kyung-Sun [1 ,2 ]
Kim, Eun Chul [1 ]
Kim, Hyun-Seung [1 ]
Kim, Jin Soo [3 ]
Hwang, Ho Sik [1 ,2 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Ophthalmol, 222 Banpo Daero, Seoul, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Dept Ophthalmol, 10,63 Ro, Seoul 07345, South Korea
[3] Hallym Univ, Chuncheon Sacred Heart Hosp, Dept Ophthalmol, 77 Sakju Ro, Chuncheon Si, Gangwon Do, South Korea
基金
新加坡国家研究基金会;
关键词
Meibum; Meibum quality; Meibomian gland dysfunction; Dry eye disease; Meiboscore; INTERNATIONAL WORKSHOP; DYSFUNCTION REPORT; DEFINITION; MORPHOLOGY; DISEASE;
D O I
10.1186/s12886-022-02509-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background In the present study, we evaluated the correlation between meibomian gland dropout and meibum quality in the same central 8 meibomian glands of the eyelid. Methods Ninety-nine eyes of 91 patients with dry eye were included in the study. Dropout of the 8 central meibomian glands of the eyelids was graded as 0, 1, 2, or 3, according to the dropout area. The meibum quality was graded as follows: grade 0, no secretion; 1, inspissated/toothpaste consistency; 2, cloudy liquid secretion; and 3, clear liquid secretion. For 68 eyes of 68 patients, correlation analysis between dropout and meibum quality was performed. To precisely analyze the direct correlation between meibomian gland dropout in meibography and meibum quality, we evaluated 31 eyes of 23 patients with focal dropout in meibography. Results The median (interquartile range) meiboscore was 1.0 (2.0) in the upper eyelids and 0.0 (1.0) in the lower eyelids. The median (interquartile range) meibum quality grade was 3.0 (1.0) in the upper eyelids and 1.0 (1.0) in the lower eyelids. No significant correlation between the meiboscore and meibum quality grade was detected in the upper (p =0.746) or lower (p =0.551) eyelids. Analysis of the direct correlation between meibomian gland dropout in meibography and meibum quality in patients with focal dropout (loss of 1 or 2 adjacent meibomian glands), however, indicated that meibomian glands with dropout secreted little to no meibum. Conclusions Overall analysis revealed no relationship between meibomian gland dropout and meibum quality, but more detailed investigation of each meibomian gland alone revealed that meibomian glands with dropout secrete little to no meibum.
引用
收藏
页数:9
相关论文
共 25 条
[1]  
Arita R., 2018, Invest Ophthalmol Vis Sci, V59, pD
[2]   Noncontact infrared meibography to document age-related changes of the meibomian glands in a normal population [J].
Arita, Reiko ;
Itoh, Kouzo ;
Inoue, Kenji ;
Amano, Shiro .
OPHTHALMOLOGY, 2008, 115 (05) :911-915
[3]  
Bron A J, 2004, Ocul Surf, V2, P149
[4]   Grading of corneal and conjunctival staining in the context of other dry eye tests [J].
Bron, AJ ;
Evans, VE ;
Smith, JA .
CORNEA, 2003, 22 (07) :640-650
[5]  
Choi M., 2019, SCI REP-UK, V9, P7468, DOI [10.1038/s41598-019-43858-4, DOI 10.1038/S41598-019-43858-4]
[6]   TFOS DEWS II Definition and Classification Report [J].
Craig, Jennifer P. ;
Nichols, Kelly K. ;
Akpek, Esen K. ;
Caffery, Barbara ;
Dua, Harminder S. ;
Joo, Choun-Ki ;
Liu, Zuguo ;
Nelson, J. Daniel ;
Nichols, Jason J. ;
Tsubota, Kazuo ;
Stapleton, Fiona .
OCULAR SURFACE, 2017, 15 (03) :276-283
[7]  
Eom Youngsub, 2019, Korean J Ophthalmol, V33, P205, DOI 10.3341/kjo.2018.0104
[8]   Comparison of Meibomian Gland Loss and Expressed Meibum Grade Between the Upper and Lower Eyelids in Patients With Obstructive Meibomian Gland Dysfunction [J].
Eom, Youngsub ;
Choi, Kwang-Eon ;
Kang, Su-Yeon ;
Lee, Hyung Keun ;
Kim, Hyo Myung ;
Song, Jong Suk .
CORNEA, 2014, 33 (05) :448-452
[9]  
Foulks Gary N, 2003, Ocul Surf, V1, P107
[10]   Lid Margins: Sensitivity, Staining, Meibomian Gland Dysfunction, and Symptoms [J].
Golebiowski, Blanka ;
Chim, Katrina ;
So, Jennifer ;
Jalbert, Isabelle .
OPTOMETRY AND VISION SCIENCE, 2012, 89 (10) :1443-1449