Stable isotope dilution mass spectrometry quantification of hydrogen sulfide and thiols in biological matrices

被引:21
作者
Malaeb, Hind [1 ,2 ,3 ]
Choucair, Ibrahim [1 ,3 ]
Wang, Zeneng [1 ,3 ]
Li, Xinmin S. [1 ,3 ]
Li, Lin [1 ,3 ]
Boyd, W. Christopher [2 ]
Hine, Christophe [1 ,3 ]
Tang, W. H. Wilson [1 ,3 ,4 ]
Gogonea, Valentin [1 ,2 ,3 ,6 ]
Hazen, Stanley L. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Dept Cardiovasc & Metab Sci, Cleveland, OH USA
[2] Cleveland State Univ, Dept Chem, Cleveland, OH USA
[3] Cleveland Clin, Ctr Microbiome & Human Hlth, Cleveland, OH USA
[4] Cleveland Clin, Dept Cardiovasc Med, Heart Vasc & Thorac Inst, Cleveland, OH USA
[5] Cleveland Clin, Lerner Res Inst, Dept Cardiovasc & Metab Sci, 9500 Euclid Ave,NC-10, Cleveland, OH 44195 USA
[6] Cleveland State Univ, Dept Chem, 2121 Euclid Ave, Cleveland, OH 44115 USA
来源
REDOX BIOLOGY | 2022年 / 55卷
基金
美国国家卫生研究院;
关键词
Hydrogen sulfide; Gut microbiota; Aging; Liquid chromatography tandem mass; spectrometry; Plasma thiol; Cysteine; Homocysteine; Glutathione; Cysteinylglycine; gamma-glutamylcysteine; Microbiome; CAPACITY; CYSTEINE; KIDNEY; STATE; H2S;
D O I
10.1016/j.redox.2022.102401
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Hydrogen sulfide (H2S), a gaseous signaling molecule that impacts multiple physiological processes including aging, is produced via select mammalian enzymes and enteric sulfur-reducing bacteria. H2S research is limited by the lack of an accurate internal standard-containing assay for its quantitation in biological matrices. Methods: After synthesizing [S-34]H2S and developing sample preparation protocols that avoid sulfide contami-nation with the addition of thiol-containing standards or reducing reagents, we developed a stable isotope-dilution high performance liquid chromatography tandem-mass spectrometry (LC-MS/MS) method for the simultaneous quantification of Total H2S and other abundant thiols (cysteine, homocysteine, glutathione, glu-tamylcysteine, cysteinylglycine) in biological matrices, conducted a 20-day analytical validation/normal range study, and then both analyzed circulating Total H2S and thiols in plasma from 400 subjects, and within 20 volunteers before and after antibiotic-induced suppression of gut microbiota. Results: Using the new assay, all analytes showed minimal interference, no carryover, and excellent intra-and inter-day reproducibility (<= 7.6%, and <= 12.7%, respectively), linearity (r(2) > 0.997), recovery (90.9%-110%) and stability (90.0%-100.5%). Only circulating Total H2S levels showed significant age-associated reductions in both males and females (p < 0.001), and a marked reduction following gut microbiota suppression (mean 33.8 +/- 17.7%, p < 0.001), with large variations in gut microbiota contribution among subjects (range 6.0-66.7% reduction with antibiotics). Conclusions: A stable-isotope-dilution LC-MS/MS method is presented for the simultaneous quantification of Total H2S and multiple thiols in biological matrices. We then use this assay panel to show a striking age-related decline and gut microbiota contribution to circulating Total H2S levels in humans.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Comparative Analysis of the Results of the Online Determination of Hydrogen Sulfide and the Results Obtained by Photometry and Chromatography–Mass Spectrometry
    E. F. Valieva
    R. M. Khatmullina
    V. I. Safarova
    I. P. Goncharova
    Journal of Analytical Chemistry, 2023, 78 : 91 - 95
  • [32] Identification and quantification by LC-MS/MS of a new precursor of 3-mercaptohexan-1-ol (3MH) using stable isotope dilution assay: Elements for understanding the 3MH production in wine
    Roland, Aurelie
    Schneider, Remi
    Le Guerneve, Christine
    Razungles, Alain
    Cavelier, Florine
    FOOD CHEMISTRY, 2010, 121 (03) : 847 - 855
  • [33] Direct determination of mercury in cosmetic samples by isotope dilution inductively coupled plasma mass spectrometry after dissolution with formic acid
    Gao, Ying
    Shi, Zeming
    Zong, Qinxia
    Wu, Peng
    Su, Jing
    Liu, Rui
    ANALYTICA CHIMICA ACTA, 2014, 812 : 6 - 11
  • [34] Development of analytical method of melamine in placenta from pregnant women by isotope-dilution liquid chromatography/tandem mass spectrometry
    Wu, Chia-Fang
    Cheng, Ching-Mei
    Hsu, Yu-Ming
    Li, Sih-Shyan
    Huang, Chung-Yi
    Chen, Yung-Hung
    Kuo, Fu-Chen
    Wu, Ming-Tsang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34
  • [35] Gas chromatographic-mass spectrometric determination of total homocysteine in human plasma by stable isotope dilution: method and clinical applications
    Ducros, V
    Schmitt, D
    Pernod, G
    Faure, H
    Polack, B
    Favier, A
    JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2): : 333 - 339
  • [36] In vivo investigation of homocysteine metabolism to polyamines by high-resolution accurate mass spectrometry and stable isotope labeling
    Ruseva, Silviya
    Lozanov, Valentin
    Markova, Petia
    Girchev, Radoslav
    Mitev, Vanio
    ANALYTICAL BIOCHEMISTRY, 2014, 457 : 38 - 47
  • [37] Validation of a universal and highly sensitive two-dimensional liquid chromatography-tandem mass spectrometry methodology for the quantification of pyrazinamide, ethambutol, protionamide, and clofazimine in different biological matrices
    Wu, Shengyuan
    Fan, Xianyu
    Jiang, Jingjing
    Ho, Chih-Ming
    Ding, Xianting
    Lou, Yuefen
    Fan, Guorong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1151
  • [38] Comparative Analysis of the Results of the Online Determination of Hydrogen Sulfide and the Results Obtained by Photometry and Chromatography-Mass Spectrometry
    Valieva, E. F.
    Khatmullina, R. M.
    Safarova, V. I.
    Goncharova, I. P.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (01) : 91 - 95
  • [39] In-line mass transport measurement cell for improving quantification in sulfide mineral analysis using laser ablation inductively coupled plasma mass spectrometry
    Watling, RJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) : 927 - 934
  • [40] Development of stable isotope dilution assays for the quantitation of the food odorants hydrogen sulphide, methanethiol, ethanethiol, and propane-1-thiol and application to durian (Durio zibethinus L.) pulp
    Li, Jia-Xiao
    Schieberle, Peter
    Steinhaus, Martin
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2017, 243 (01) : 69 - 79