Stable isotope dilution mass spectrometry quantification of hydrogen sulfide and thiols in biological matrices

被引:21
作者
Malaeb, Hind [1 ,2 ,3 ]
Choucair, Ibrahim [1 ,3 ]
Wang, Zeneng [1 ,3 ]
Li, Xinmin S. [1 ,3 ]
Li, Lin [1 ,3 ]
Boyd, W. Christopher [2 ]
Hine, Christophe [1 ,3 ]
Tang, W. H. Wilson [1 ,3 ,4 ]
Gogonea, Valentin [1 ,2 ,3 ,6 ]
Hazen, Stanley L. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Dept Cardiovasc & Metab Sci, Cleveland, OH USA
[2] Cleveland State Univ, Dept Chem, Cleveland, OH USA
[3] Cleveland Clin, Ctr Microbiome & Human Hlth, Cleveland, OH USA
[4] Cleveland Clin, Dept Cardiovasc Med, Heart Vasc & Thorac Inst, Cleveland, OH USA
[5] Cleveland Clin, Lerner Res Inst, Dept Cardiovasc & Metab Sci, 9500 Euclid Ave,NC-10, Cleveland, OH 44195 USA
[6] Cleveland State Univ, Dept Chem, 2121 Euclid Ave, Cleveland, OH 44115 USA
来源
REDOX BIOLOGY | 2022年 / 55卷
基金
美国国家卫生研究院;
关键词
Hydrogen sulfide; Gut microbiota; Aging; Liquid chromatography tandem mass; spectrometry; Plasma thiol; Cysteine; Homocysteine; Glutathione; Cysteinylglycine; gamma-glutamylcysteine; Microbiome; CAPACITY; CYSTEINE; KIDNEY; STATE; H2S;
D O I
10.1016/j.redox.2022.102401
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Hydrogen sulfide (H2S), a gaseous signaling molecule that impacts multiple physiological processes including aging, is produced via select mammalian enzymes and enteric sulfur-reducing bacteria. H2S research is limited by the lack of an accurate internal standard-containing assay for its quantitation in biological matrices. Methods: After synthesizing [S-34]H2S and developing sample preparation protocols that avoid sulfide contami-nation with the addition of thiol-containing standards or reducing reagents, we developed a stable isotope-dilution high performance liquid chromatography tandem-mass spectrometry (LC-MS/MS) method for the simultaneous quantification of Total H2S and other abundant thiols (cysteine, homocysteine, glutathione, glu-tamylcysteine, cysteinylglycine) in biological matrices, conducted a 20-day analytical validation/normal range study, and then both analyzed circulating Total H2S and thiols in plasma from 400 subjects, and within 20 volunteers before and after antibiotic-induced suppression of gut microbiota. Results: Using the new assay, all analytes showed minimal interference, no carryover, and excellent intra-and inter-day reproducibility (<= 7.6%, and <= 12.7%, respectively), linearity (r(2) > 0.997), recovery (90.9%-110%) and stability (90.0%-100.5%). Only circulating Total H2S levels showed significant age-associated reductions in both males and females (p < 0.001), and a marked reduction following gut microbiota suppression (mean 33.8 +/- 17.7%, p < 0.001), with large variations in gut microbiota contribution among subjects (range 6.0-66.7% reduction with antibiotics). Conclusions: A stable-isotope-dilution LC-MS/MS method is presented for the simultaneous quantification of Total H2S and multiple thiols in biological matrices. We then use this assay panel to show a striking age-related decline and gut microbiota contribution to circulating Total H2S levels in humans.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Fluorescent Probes and Mass Spectrometry-Based Methods to Quantify Thiols in Biological Systems
    Wang, Lingfei
    Jin, Feng
    Jiang, Xiqian
    Chen, Jianwei
    Wang, Meng C.
    Wang, Jin
    ANTIOXIDANTS & REDOX SIGNALING, 2022, 36 (4-6) : 354 - 365
  • [22] Profiling thiol metabolites in myocardial infarction human serum by stable isotope labeling assisted liquid chromatography-mass spectrometry
    He, Ke
    Wang, Ya-Lan
    Zhu, Quan-Fei
    Cheng, Li-Ming
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1126
  • [23] Stable isotope labeling method targeting terminal tyrosine for relative peptide quantitation using mass spectrometry
    Choi, Yong Seok
    Pennington, Christopher L.
    Wood, Troy D.
    ANALYTICAL BIOCHEMISTRY, 2010, 401 (01) : 15 - 21
  • [24] Stable isotope labeling combined with liquid chromatography-tandem mass spectrometry for comprehensive analysis of short-chain fatty acids
    Zheng, Jie
    Zheng, Shu-Jian
    Cai, Wen-Jing
    Yu, Lei
    Yuan, Bi-Feng
    Feng, Yu-Qi
    ANALYTICA CHIMICA ACTA, 2019, 1070 : 51 - 59
  • [25] Simultaneous analysis of six aldehyde-DNA adducts in salivary DNA of nonsmokers and smokers using stable isotope dilution liquid chromatography electrospray ionization-tandem mass spectrometry
    Li, Xiangyu
    Liu, Lujuan
    Wang, Hongjuan
    Chen, Jian
    Zhu, Beibei
    Chen, Huan
    Hou, Hongwei
    Hu, Qingyuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 : 451 - 459
  • [26] Quantitative analysis of penicillins in porcine tissues, milk and animal feed using derivatisation with piperidine and stable isotope dilution liquid chromatography tandem mass spectrometry
    van Holthoon, Frederique
    Mulder, Patrick P. J.
    van Bennekom, Eric O.
    Heskamp, Henri
    Zuidema, Tina
    van Rhijn, Hans A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 3027 - 3040
  • [27] Profiling of Thiol-Containing Compounds by Stable Isotope Labeling Double Precursor Ion Scan Mass Spectrometry
    Liu, Ping
    Huang, Yun-Qing
    Cai, Wen-Jing
    Yuan, Bi-Feng
    Feng, Yu-Qi
    ANALYTICAL CHEMISTRY, 2014, 86 (19) : 9765 - 9773
  • [28] Stable-isotope dilution LC-ESI-MS/MS techniques for the quantification of total homocysteine in human plasma
    Tomaiuolo, Michela
    Vecchione, Gennaro
    Margaglione, Maurizio
    Pisanelli, Daniela
    Grandone, Elvira
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (28): : 3292 - 3299
  • [29] Fatal poisoning of four workers in a farm: Distribution of hydrogen sulfide and thiosulfate in 10 different biological matrices
    Moretti, Matteo
    Ballardini, Marco
    Siodambro, Chiara
    Tronconi, Livio
    Osculati, Antonio Marco Maria
    Freni, Francesca
    Vignali, Claudia
    Morini, Luca
    FORENSIC SCIENCE INTERNATIONAL, 2020, 316
  • [30] Development and validation of a simple isotope dilution-liquid chromatography-tandem mass spectrometry method for detecting vitamins A and E in serum and amniotic fluid
    Yu, Songlin
    Yin, Yicong
    Wang, Danchen
    Xie, Shaowei
    Cheng, Qian
    Cheng, Xinqi
    Qiu, Ling