The effect of long-term, daily contact lens wear on corneal sensitivity

被引:78
|
作者
Murphy, PJ
Patel, S
Marshall, J
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
[2] Common Serv Agcy, Edinburgh, Midlothian, Scotland
[3] Scottish Execut, Edinburgh, Midlothian, Scotland
[4] St Thomas Hosp, Dept Expt Ophthalmol, London, England
关键词
contact lenses; corneal sensitivity; aesthesiometry; corneal nerve function;
D O I
10.1097/00003226-200104000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the effect of long-term, daily-wear soft contact lenses and rigid gas permeable (RGP) contact lenses on corneal sensitivity using a noninvasive, air-pulse stimulus. Methods. The central and peripheral (temporal, medial, inferior) corneal sensation thresholds of 40 non-lens wearers, 40 soft lens wearers, and 40 RGP lens wearers were assessed using the Non-Contact Corneal Aesthesiometer (NCCA). The individuals who wore contact lenses were grouped according to the number of years of lens wear (10 years or less, 11-20 years, and 21 years or more). Results. Although a significant reduction in corneal sensitivity was found between the contact lens wearers and non-lens wearers (p = 0.000), no difference was found between the two lens-type subgroups (p = 0.939). This pattern of significance was repeated at each of the peripheral test locations. No relationship between corneal sensitivity and years of lens wear was found centrally (r(2) = 0.001) or at any of the peripheral test locations. No significant difference was found between the central corneal sensation thresholds for the different subgroups of lens wear duration (p = 0.469) or for any of the peripheral test locations. Conclusions. Both soft and RGP lens wear produce a similar type of corneal sensitivity loss, although the mechanism for this loss is different for the two lens types. The extent of sensitivity loss is not related to the duration of lens wear and appears to plateau after the first few months of wear. No topographical variation in sensitivity loss was found with lens type or with the duration of lens wear.
引用
收藏
页码:264 / 269
页数:6
相关论文
共 50 条
  • [41] Real-Time Changes in the Comfort of a Toric, Monthly, Soft Contact Lens Over a Long Day of Wear
    Lievens, Chris
    Perkins, Amy
    Rayborn, Elyse
    Wang, Yueren
    Franklin, Quentin
    May, Kristopher
    Kannarr, Shane
    Bromley, Morgan
    Pucker, Andrew D.
    CLINICAL OPTOMETRY, 2024, 16 : 317 - 325
  • [42] Long-Term Use of Hydroxypropyl Cellulose Ophthalmic Insert to Relieve Symptoms of Dry Eye in a Contact Lens Wearer: Case-Based Experience
    Wander, Arden H.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (01): : 39 - 44
  • [43] Effect of lens base curve on subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses
    Dumbleton, KA
    Chalmers, RL
    McNally, J
    Bayer, S
    Fonn, D
    OPTOMETRY AND VISION SCIENCE, 2002, 79 (10) : 633 - 637
  • [44] Short-Term and Long-Term Changes in Corneal Power Are Not Correlated With Axial Elongation of the Eye Induced by Orthokeratology in Children
    Santodomingo-Rubido, Jacinto
    Villa-Collar, Cesar
    Gilmartin, Bernard
    Gutierrez-Ortega, Ramon
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 (04): : 260 - 267
  • [45] Short- and Long-Term Changes in Corneal Aberrations and Axial Length Induced by Orthokeratology in Children Are Not Correlated
    Santodomingo-Rubido, Jacinto
    Villa-Collar, Cesar
    Gilmartin, Bernard
    Gutierrez-Ortega, Ramon
    Suzaki, Asaki
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (06): : 358 - 363
  • [46] Long-Term Outcome after Penetrating Keratoplasty for Keratoconus - Impact of Preoperative Corneal Curvature and Best Corrected Visual Acuity on the Functional Results
    Preclik, A.
    Langenbucher, A.
    Seitz, B.
    Cursiefen, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (03) : 199 - 207
  • [47] Short-term effect of topical antiglaucoma medication on tear-film stability, tear secretion, and corneal sensitivity in healthy subjects
    Terai, Naim
    Mueller-Holz, Matthias
    Spoerl, Eberhard
    Pillunat, Lutz E.
    CLINICAL OPHTHALMOLOGY, 2011, 5 : 517 - 525
  • [48] Long-term myopia control effect and safety in children wearing DIMS spectacle lenses for 6 years
    Lam, Carly Siu Yin
    Tang, Wing Chun
    Zhang, Han Yu
    Lee, Paul H.
    Tse, Dennis Yan Yin
    Qi, Hua
    Vlasak, Natalia
    To, Chi Ho
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [49] Long-term clinical efficacy of topical treatment with recombinant human nerve growth factor in neurotrophic keratopathy: a novel cure for a rare degenerative corneal disease?
    Bruscolini, Alice
    Marenco, Marco
    Albanese, Giuseppe Maria
    Lambiase, Alessandro
    Sacchetti, Marta
    ORPHANET JOURNAL OF RARE DISEASES, 2022, 17 (01)
  • [50] Long-term clinical efficacy of topical treatment with recombinant human nerve growth factor in neurotrophic keratopathy: a novel cure for a rare degenerative corneal disease?
    Alice Bruscolini
    Marco Marenco
    Giuseppe Maria Albanese
    Alessandro Lambiase
    Marta Sacchetti
    Orphanet Journal of Rare Diseases, 17