The effect of long-term, daily contact lens wear on corneal sensitivity

被引:78
作者
Murphy, PJ
Patel, S
Marshall, J
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
[2] Common Serv Agcy, Edinburgh, Midlothian, Scotland
[3] Scottish Execut, Edinburgh, Midlothian, Scotland
[4] St Thomas Hosp, Dept Expt Ophthalmol, London, England
关键词
contact lenses; corneal sensitivity; aesthesiometry; corneal nerve function;
D O I
10.1097/00003226-200104000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the effect of long-term, daily-wear soft contact lenses and rigid gas permeable (RGP) contact lenses on corneal sensitivity using a noninvasive, air-pulse stimulus. Methods. The central and peripheral (temporal, medial, inferior) corneal sensation thresholds of 40 non-lens wearers, 40 soft lens wearers, and 40 RGP lens wearers were assessed using the Non-Contact Corneal Aesthesiometer (NCCA). The individuals who wore contact lenses were grouped according to the number of years of lens wear (10 years or less, 11-20 years, and 21 years or more). Results. Although a significant reduction in corneal sensitivity was found between the contact lens wearers and non-lens wearers (p = 0.000), no difference was found between the two lens-type subgroups (p = 0.939). This pattern of significance was repeated at each of the peripheral test locations. No relationship between corneal sensitivity and years of lens wear was found centrally (r(2) = 0.001) or at any of the peripheral test locations. No significant difference was found between the central corneal sensation thresholds for the different subgroups of lens wear duration (p = 0.469) or for any of the peripheral test locations. Conclusions. Both soft and RGP lens wear produce a similar type of corneal sensitivity loss, although the mechanism for this loss is different for the two lens types. The extent of sensitivity loss is not related to the duration of lens wear and appears to plateau after the first few months of wear. No topographical variation in sensitivity loss was found with lens type or with the duration of lens wear.
引用
收藏
页码:264 / 269
页数:6
相关论文
共 42 条
[1]  
BELMONTE C, 1996, PROG RETIN EYE RES, V16, P118
[2]  
Bergenske P D, 1987, J Am Optom Assoc, V58, P212
[3]  
Bland JM, 1996, BRIT MED J, V312, P770
[4]  
BOBERG-ANS J, 1955, Br J Ophthalmol, V39, P705, DOI 10.1136/bjo.39.12.705
[5]   ESTHESIOMETRY AS AN INDICATOR OF CORNEAL HEALTH [J].
BRENNAN, NA ;
BRUCE, AS .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (09) :699-702
[6]   *SENSIBILITAT UND ACETYLCHOLINGEHALT DER HORNHAUT VERSCHIEDENER TIERE UND DES MENSCHEN [J].
HELLAUER, HF .
ZEITSCHRIFT FUR VERGLEICHENDE PHYSIOLOGIE, 1950, 32 (04) :303-310
[7]  
KNOLL HA, 1970, AMER J OPT ARCH AM A, V47, P561
[8]   SOME CLINICALLY OBSERVED PHENOMENA IN EXTENDED CONTACT-LENS WEAR [J].
LARKE, JR ;
HIRJI, NK .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1979, 63 (07) :475-477
[9]   ELECTRO-MECHANICAL CORNEAL AESTHESIOMETER [J].
LARSON, WL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1970, 54 (05) :342-&
[10]  
LIND GJ, 1993, INVEST OPHTH VIS SCI, V34, P2943