Bacterial assay of contact lens wearers

被引:10
作者
Hart, DE [1 ]
Hosmer, M [1 ]
Georgescu, M [1 ]
Farris, RL [1 ]
机构
[1] COLUMBIA UNIV,COLL PHYS & SURG,PRESBYTERIAN HOSP,EDWARD S HARKNESS EYE INST,DEPT OPHTHALMOL,NEW YORK,NY
关键词
contact lenses; microorganisms; bacteria; lids; lashes; tear fluid;
D O I
10.1097/00006324-199603000-00014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The goal of the project was to determine the quantity of bacteria on the contact lens and adjacent areas of the eye. This paper is a quantitative study of the contact lens and ocular aerobic microbiota in a mixed group of daily and extended wear disposable contact lens users. Methods. The contact lens, the lower fornix, tears collecting at the lower fornix, and edge of the lower lid at the Meibomian gland margin were assayed for the quantity of bacterial colony forming units (CFU). Eighteen patients wearing 49 disposable high water content hydrogel contact lenses were assayed and the mean lens age was 8.8 +/- 4.6 days. Three patients wore their lenses on a daily wear basis and 15 on an extended wear schedule. Tear samples were obtained with sterile microbial loops and the lens was macerated into small particles with a tissue grinder. The samples were poured onto the surface of chocolate agar plates and incubated at 35 degrees C for 48 h in 5% CO2. Results. The lid margin revealed the greatest bacterial presence (mean = 9.7 CFU; median = 2 CFU; mode = 0 CFU). The lens showed the next greatest presence of CFU (mean 4.5 CFU; median = 1 CFU; mode = 0). The fornix and tears revealed the least bacterial presence (fornix: mean = 2.6 CFU; median = 0 CFU; mode = 0 CFU) (tears: mean = 1.6 CFU; median = 0 CFU; mode = 0 CFU). The bacteria were coagulase-negative staphylococci. Conclusions. The bacterial assay of disposable lens wearing contact lens subjects indicates that the lid margins are the greatest source of bacteria with the tears being the lowest. These studies support the concept that in the eye, the lens typically does not possess a large number of bacteria under normal conditions.
引用
收藏
页码:204 / 207
页数:4
相关论文
共 50 条
[41]   Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers [J].
Itokawa, Takashi ;
Okajima, Yukinobu ;
Suzuki, Takashi ;
Kakisu, Koji ;
Iwashita, Hiroko ;
Murakami, Yoshitaka ;
Hori, Yuichi .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (02) :771-775
[42]   Determining the information needs of contact lens wearers for better education and more support: a qualitative study [J].
Falahati-Marvast, Fatemeh ;
Alipour, Fateme ;
Farokhzadian, Jamileh ;
Ahmadian, Leila .
BMC OPHTHALMOLOGY, 2021, 21 (01)
[43]   Investigation of Delefilcon A Contact Lenses for Symptomatic Daily Disposable Contact Lens Wearers with Dry Eye Disease: A Prospective Comparative Study [J].
Guthrie, Sarah E. ;
Luensmann, Doerte ;
Schulze, Marc-Matthias ;
Woods, Jill ;
Jones, Lyndon .
CLINICAL OPHTHALMOLOGY, 2024, 18 :2999-3008
[44]   Clinical and molecular diagnosis of Acanthamoeba keratitis in contact lens wearers in southern Brazil reveals the presence of an endosymbiont [J].
dos Santos, Denise Leal ;
Virginio, Veridiana Gomes ;
Berte, Francisco Kercher ;
Lorenzatto, Karina Rodrigues ;
Marinho, Diane Ruschel ;
Kwitko, Sergio ;
Locatelli, Claudete Ines ;
Freitas, Eduarda Correa ;
Rott, Marilise Brittes .
PARASITOLOGY RESEARCH, 2022, 121 (05) :1447-1454
[45]   Clinical and molecular diagnosis of Acanthamoeba keratitis in contact lens wearers in southern Brazil reveals the presence of an endosymbiont [J].
Denise Leal dos Santos ;
Veridiana Gomes Virginio ;
Francisco Kercher Berté ;
Karina Rodrigues Lorenzatto ;
Diane Ruschel Marinho ;
Sergio Kwitko ;
Claudete Inês Locatelli ;
Eduarda Correa Freitas ;
Marilise Brittes Rott .
Parasitology Research, 2022, 121 :1447-1454
[46]   Case-Control Pilot Study of Soft Contact Lens Wearers With Corneal Infiltrative Events and Healthy Controls [J].
Richdale, Kathryn ;
Lam, Dawn Y. ;
Wagner, Heidi ;
Zimmerman, Aaron B. ;
Kinoshita, Beth T. ;
Chalmers, Robin ;
Sorbara, Luigina ;
Szczotka-Flynn, Loretta ;
Govindarajulu, Usha ;
Mitchell, G. Lynn .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (01) :47-55
[47]   Zur Ätiologie des Hornhautulkus beim KontaktlinsenträgerThe etiology of corneal ulcers among contact lens wearers [J].
H. W. Roth .
Spektrum der Augenheilkunde, 2002, 16 (5) :198-202
[48]   FLUORESCENCE ASSAY FOR MEASURING LIPID DEPOSITS ON CONTACT-LENS SURFACES [J].
HO, CH ;
HLADY, V .
BIOMATERIALS, 1995, 16 (06) :479-482
[49]   Parasitological and microbiological assessment of contact lens storage cases: a survey of asymptomatic lens student wearers from five medical specialties in Tunisia, North Africa [J].
Belgacem, Sameh ;
Chaabane-Banaoues, Raja ;
Mejri, Amira ;
Ben Ifa, Sawsen ;
Mastouri, Maha ;
Babba, Hamouda .
BMC INFECTIOUS DISEASES, 2025, 25 (01)
[50]   Risk Factors for Contact Lens Bacterial Contamination During Continuous Wear [J].
Szczotka-Flynn, Loretta B. ;
Bajaksouzian, Saralee ;
Jacobs, Michael R. ;
Rimm, Alfred .
OPTOMETRY AND VISION SCIENCE, 2009, 86 (11) :1216-1226