A selection guide for the new generation 6-dye DNA profiling systems

被引:23
作者
Lin, Sze-Wah [1 ]
Li, Christina [1 ]
Ip, Stephen C. Y. [1 ]
机构
[1] Homantin Govt Off, Govt Lab, Forens Sci Div, Hong Kong, Hong Kong, Peoples R China
关键词
Forensic DNA typing; Identifiler plus; Investigator; 24plex; GlobalFiler; Fusion; 6C; CODIS CORE LOCI; FUSION 6C SYSTEM; DEVELOPMENTAL VALIDATION; UNITED-STATES; KIT; FINGERPRINTS;
D O I
10.1016/j.fsigen.2017.05.010
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
The Federal Bureau of Investigation (FBI) has recently expanded the CODIS core loci from the existing 13 to 20 as a new guideline, and laboratories from the US are required to comply with the new regulation before uploading or conducting identity search in the national database. The expanded CODIS format, which shares all the core loci commonly used in the European countries and the US, not only increases international compatibility, but also reduces the number of adventitious matches, and hence facilitates international law enforcement and counterterrorism endeavours. Here, we review the key performance measures of three new STR amplification systems with 6-dye chemistry, namely, the Investigator 24plex QS Kit from QIAGEN, the GlobalFiler (TM) PCR Amplification Kit from Applied Biosystems (TM), and the PowerPlex (R) Fusion 6C System from Promega. Our results have demonstrated that GlobalFiler displays the highest sensitivity among the tested kits, whereas Investigator 24plex shows a higher tolerance to common PCR inhibitors including Humic acid and Tannic acid. GlobalFiler and Fusion 6C, on the other hand, yield DNA profiles with better heterozygous peak height and intra-colour signal balance. Both GlobalFiler and Investigator 24plex exhibit slightly higher sensitivity than Fusion 6C in the profiling of minor components in DNA mixture, but the latter displays a higher consistency in the preservation of the mixture ratio. In summary, our work has demonstrated that these three profiling systems have their different performance features, and hence it is recommended that laboratories should select the most suitable kits according to their own requirements and operational needs. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 42
页数:9
相关论文
共 20 条
[11]   Selection and implementation of expanded CODIS core loci in the United States [J].
Hares, Douglas R. .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2015, 17 :33-34
[12]   Addendum to expanding the CODIS core loci in the United States [J].
Hares, Douglas R. .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2012, 6 (05) :E135-E135
[13]   Expanding the CODIS core loci in the United States [J].
Hares, Douglas R. .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2012, 6 (01) :E52-E54
[14]   INDIVIDUAL-SPECIFIC FINGERPRINTS OF HUMAN DNA [J].
JEFFREYS, AJ ;
WILSON, V ;
THEIN, SL .
NATURE, 1985, 316 (6023) :76-79
[15]   Developmental validation of QIAGEN Investigator® 24plex QS Kit and Investigator® 24plex GO! Kit: Two 6-dye multiplex assays for the extended CODIS core loci [J].
Kraemer, Melanie ;
Prochnow, Anke ;
Bussmann, Michael ;
Scherer, Mario ;
Peist, Ralf ;
Steffen, Carolyn .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2017, 29 :9-20
[16]   Improving DNA data exchange: Validation studies on a single 6 dye STR kit with 24 loci [J].
Martin, Pablo ;
Fernandez de Simon, Lourdes ;
Luque, Gracia ;
Jose Farfan, Maria ;
Alonso, Antonio .
FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2014, 13 :68-78
[17]   Initial experience in the application of the PowerQuant (TM) system and the Investigator (R) ESSplex SE QS kit for aDNA analysis [J].
Pflugbeil, A. M. ;
Gross, S. ;
Rothe, J. ;
Heinke, F. ;
Bruchhaus, H. ;
Edelmann, J. ;
Labudde, D. ;
Dressler, J. ;
Thiele, K. .
FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2015, 5 :E420-E421
[18]   Improving sample analysis and interpretation using QIAGEN's latest Investigator (R) STR multiplex PCR assays with a novel quality sensor [J].
Scherer, M. ;
Koenig, M. ;
Breitbach, M. ;
Cornelius, S. ;
Bussmann, M. ;
Prochnow, A. ;
Peist, R. .
FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2015, 5 :E308-E309
[19]   CHELEX-100 AS A MEDIUM FOR SIMPLE EXTRACTION OF DNA FOR PCR-BASED TYPING FROM FORENSIC MATERIAL [J].
WALSH, PS ;
METZGER, DA ;
HIGUCHI, R .
BIOTECHNIQUES, 1991, 10 (04) :506-513
[20]   Developmental Validation of the AmpFlSTR® Identifiler® Plus PCR Amplification Kit: An Established Multiplex Assay with Improved Performance [J].
Wang, Dennis Y. ;
Chang, Chien-Wei ;
Lagace, Robert E. ;
Calandro, Lisa M. ;
Hennessy, Lori K. .
JOURNAL OF FORENSIC SCIENCES, 2012, 57 (02) :453-465