摘要
Native amino acids and peptides were detected at a copper microelectrode using sinusoidal voltammetry (SV). Traditionally, these molecules can only be measured after derivatization with either a fluorescent or electroactive tag. In this:work, an electrocatalytic oxidation reaction at copper is used to detect underivatized peptides and amino acids; The:oxidation reaction is somewhat independent of peptide structure (i.e., it is not limited to the detection of aromatic amino acids) and is therefore able to produce nanomolar detection limits for all amino acids and peptides tested. A scanning technique, sinusoidal voltammetry, is used to provide the sensitivity of constant-potential techniques but also provide selectivity gained through utilization of the frequency domain. The frequency spectrum due to the oxidation of each molecule has a unique "fingerprint" response resulting from the kinetics of oxidation at the electrode surface. Through examination of the frequency spectra, even structurally similar molecules can be easily distinguished from one another. mow injection analysis is used to demonstrate the sensitive and selective detection of a variety of amino acids and peptides.:This technique can also be easily coupled to a separation step, i.e., high-performance liquid chromatography or capillary electrophoresis without electrode fouling fi-om the adsorption of the analytes.
引用
收藏
页码:5542 / 5548
页数:7
相关论文
共 47 条
[1]   Insulin-stimulated insulin secretion in single pancreatic beta cells [J].
Aspinwall, CA ;
Lakey, JRT ;
Kennedy, RT .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (10) :6360-6365
[2]   Effects of intravesicular H+ and extracellular H+ and Zn2+ on insulin secretion in pancreatic beta cells [J].
Aspinwall, CA ;
Brooks, SA ;
Kennedy, RT ;
Lakey, JRT .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (50) :31308-31314
[3]   Capillary electrophoresis with laser-induced fluorescence detection: A sensitive method for monitoring extracellular concentrations of amino acids in the periaqueductal grey matter [J].
Bergquist, J ;
Vona, MJ ;
Stiller, CO ;
OConnor, WT ;
Falkenberg, T ;
Ekman, R .
JOURNAL OF NEUROSCIENCE METHODS, 1996, 65 (01) :33-42
[4]   Trace-level amino acid analysis by capillary liquid chromatography and application to in vivo microdialysis sampling with 10-s temporal resolution [J].
Boyd, BW ;
Witowski, SR ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :865-871
[5]   DETECTION OF BIOACTIVE OLIGOPEPTIDES AFTER MICROBORE HPLC WITH ELECTROCHEMICAL DETECTION OF THEIR CU(II) COMPLEXES - EFFECT OF OPERATING PARAMETERS ON SENSITIVITY AND SELECTIVITY [J].
CHEN, JG ;
WEBER, SG .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3596-3604
[6]   SENSITIVITY AND SELECTIVITY OF THE ELECTROCHEMICAL DETECTION OF THE COPPER(II) COMPLEXES OF BIOACTIVE PEPTIDES, AND COMPARISON TO MODEL STUDIES BY ROTATING RING-DISC ELECTRODE [J].
CHEN, JG ;
WOLTMAN, SJ ;
WEBER, SG .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :301-315
[7]   DETERMINATION OF CARBOHYDRATES BY CAPILLARY ZONE ELECTROPHORESIS WITH AMPEROMETRIC DETECTION AT A COPPER MICROELECTRODE [J].
COLON, LA ;
DADOO, R ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :476-481
[8]   DETERMINATION OF PEPTIDES BY CAPILLARY ELECTROPHORESIS ELECTROCHEMICAL DETECTION USING ON-COLUMN CU(II) COMPLEXATION [J].
DEACON, M ;
OSHEA, TJ ;
LUNTE, SM ;
SMYTH, MR .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (02) :377-383
[9]   COPPER WIRE AMPEROMETRIC DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
ENGSTROMSILVERMAN, CE ;
EWING, AG .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (02) :141-145
[10]   SIMULTANEOUS ANALYSIS OF METHIONINE-ENKEPHALIN AND LEUCINE-ENKEPHALIN FROM RAT-BRAIN - QUANTIFICATION BY LIQUID-CHROMATOGRAPHY - ELECTROCHEMISTRY [J].
FLEMING, LH ;
REYNOLDS, NC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 431 (01) :65-76