Evaluation of Out-Of-Field Dose Calculation Accuracy of Monaco Treatment Planning System for a 1.5T MR-Linac

被引:0
|
作者
Zhang, Y. [1 ,2 ]
Yan, S. [2 ,3 ]
Li, Z. [2 ]
Li, B. [2 ]
Quan, H. [1 ]
Zhu, J. [2 ]
机构
[1] Wuhan Univ, Wuhan, Peoples R China
[2] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp & Inst, Jinan, Peoples R China
[3] Univ South China, Hengyang, Peoples R China
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-T-
引用
收藏
页数:1
相关论文
共 50 条
  • [1] A comparison of measured and treatment planning system out-of-field dose for a 1.5 T MR linac
    Powers, Marcus
    Baines, John
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (20):
  • [2] Out-of-field dose and its constituent components for a 1.5 T MR-Linac
    Yang, Bin
    Tang, Ka Keung
    Huang, Chen-Yu
    Geng, Hui
    Lam, Wai Wang
    Wong, Yeung Sum
    Tse, Mei Yan
    Lau, Ka Ki
    Cheung, Kin Yin
    Yu, Siu Ki
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (22):
  • [3] Out-of-field dose assessment for a 1.5 T MR-Linac with optically stimulated luminescence dosimeters
    Zhang, Yan
    Yan, Shaojie
    Cui, Zhen
    Wang, Yungang
    Li, Zhenjiang
    Yin, Yong
    Li, Baosheng
    Quan, Hong
    Zhu, Jian
    MEDICAL PHYSICS, 2021, 48 (07) : 4027 - 4037
  • [4] Sources of out-of-field dose in MRgRT: an inter-comparison of measured and Monaco treatment planning system doses for the Elekta Unity MR-linac
    John Baines
    Marcus Powers
    Glen Newman
    Physical and Engineering Sciences in Medicine, 2021, 44 : 1049 - 1059
  • [5] Sources of out-of-field dose in MRgRT: an inter-comparison of measured and Monaco treatment planning system doses for the Elekta Unity MR-linac
    Baines, John
    Powers, Marcus
    Newman, Glen
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (04) : 1049 - 1059
  • [6] Online Adaptive Planning Strategy for 1.5T MR-Linac
    Yang, J.
    Sobremonte, A.
    Vedam, S.
    Brock, K.
    Ohrt, A.
    Fuller, C.
    Choi, S.
    Jhingran, A.
    Castillo, P.
    Lee, B.
    Wang, J.
    Hughes, N.
    Mohammadsaid, M.
    Balter, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E643 - E643
  • [7] Dose Calculation Accuracy of Beam Models in RadCalc for a 1.5 T MR-Linac
    Sung, Jiwon
    Choi, Yeonho
    Kim, Jun Won
    Lee, Ho
    CANCERS, 2024, 16 (03)
  • [8] Evaluation of the Geometric Distortion in Clinical MR Sequences for a 1.5T MR-Linac System
    Aima, M.
    Slagowski, J. M.
    Ding, Y.
    Vedam, S.
    Yang, J.
    Hwang, K.
    Szklaruk, J.
    Choi, S.
    Fuller, C. D.
    Chung, C.
    Wang, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E684 - E685
  • [9] Performance of a multileaf collimator system for a 1.5T MR-linac
    Zhang, Ke
    Tian, Yuan
    Li, Minghui
    Men, Kuo
    Dai, Jianrong
    MEDICAL PHYSICS, 2021, 48 (02) : 546 - 555
  • [10] Time trends for online adapative treatment on the 1.5T MR-Linac
    Westerhoff, J.
    Daamen, A.
    de Groot-van Breugel, E. N.
    van Zyp, J. R. N. van der Voort
    Verhoeff, J. J. C.
    Mook, S.
    Verkooijen, H. M.
    Intven, M. P. W.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S110 - S111