Mass spectrometry and viral analysis

被引:150
作者
Siuzdak, G
Bothner, B
Yeager, M
Brugidou, C
Fauquet, CM
Hoey, K
Chang, CM
机构
[1] Scripps Res Inst, RES INST, DEPT CELL BIOL, LA JOLLA, CA 92037 USA
[2] Scripps Res Inst, RES INST, INT LAB TROP AGR BIOTECHNOL, LA JOLLA, CA 92037 USA
[3] RW JOHNSON PHARMACEUT RES INST, PEPTIDE SYNTH LAB, SAN DIEGO, CA 92121 USA
来源
CHEMISTRY & BIOLOGY | 1996年 / 3卷 / 01期
关键词
electron microscopy; electrospray; mass spectrometry; non-covalent; virus;
D O I
10.1016/S1074-5521(96)90083-6
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Electrospray ionization (ESI) mass spectrometry is a powerful new approach for analyzing biomolecules and biomolecular complexes. Previous studies have provided evidence that non-covalent biomolecular complexes can be observed by ESI mass spectrometry; it is not clear, however, whether the native conformation oi the biomolecules is maintained throughout the ionization and analysis process. We set out to address this question using live viruses. Results: Viral ions have been generated in the gas phase using electrospray ionization mass spectrometry. These ions have been collected, following ion filtering through the mass analyzer, and then analyzed by transmission electron microscopy. Transmission electron microscopy revealed that rice yellow mottle virus and tobacco mosaic virus retained their respective spherical and rod-like ultrastructure. The viability of the isolated tobacco mosaic virus was confirmed by inoculation and infection of tobacco plants. Conclusions: These results demonstrate the utility of electrospray for supramolecular complexes with molecular weights of over 40 million Da and offer conclusive evidence that native biomolecular structures can be conserved through the electrospray process.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 20 条
[1]  
[Anonymous], FIELDS VIROLOGY
[2]   DOES THE OBSERVATION OF NONCOVALENT COMPLEXES BETWEEN BIOMOLECULES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY NECESSARILY REFLECT SPECIFIC SOLUTION INTERACTIONS [J].
APLIN, RT ;
ROBINSON, CV ;
SCHOFIELD, CJ ;
WESTWOOD, NJ .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1994, (20) :2415-2417
[3]   DIRECT OBSERVATION OF A TERNARY COMPLEX BETWEEN THE DIMERIC ENZYME HIV-1 PROTEASE AND A SUBSTRATE-BASED INHIBITOR [J].
BACA, M ;
KENT, SBH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (10) :3992-3993
[4]   SYNTHESIS OF AN INFECTIOUS FULL-LENGTH CDNA CLONE OF RICE YELLOW MOTTLE VIRUS AND MUTAGENESIS OF THE COAT PROTEIN [J].
BRUGIDOU, C ;
HOLT, C ;
YASSI, MNA ;
ZHANG, S ;
BEACHY, R ;
FAUQUET, C .
VIROLOGY, 1995, 206 (01) :108-115
[5]   TRAPPING, DETECTION, AND MASS DETERMINATION OF COLIPHAGE T4 DNA IONS OF 10(8) DA BY ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, RD ;
CHENG, XH ;
MITCHELL, DW ;
HOFSTADLER, SA ;
WU, QY ;
ROCKWOOD, AL ;
SHERMAN, MG ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (07) :1159-1163
[6]   ANALYSIS OF ANTIBODIES AND OTHER LARGE GLYCOPROTEINS IN THE MASS RANGE OF 150000-200000 DA BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY [J].
FENG, R ;
KONISHI, Y .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2090-2095
[7]   OBSERVATION OF DUPLEX DNA-DRUG NONCOVALENT COMPLEXES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
GALE, DC ;
GOODLETT, DR ;
LIGHTWAHL, KJ ;
SMITH, RD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (13) :6027-6028
[8]   DETECTION OF NONCOVALENT RECEPTOR LIGAND COMPLEXES BY MASS-SPECTROMETRY [J].
GANEM, B ;
LI, YT ;
HENION, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (16) :6294-6296
[9]   OBSERVATION OF THE HEME GLOBIN COMPLEX IN NATIVE MYOGLOBIN BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
KATTA, V ;
CHAIT, BT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (22) :8534-8535
[10]   DETECTION OF A CATALYTIC ANTIBODY SPECIES ACYLATED AT THE ACTIVE-SITE BY ELECTROSPRAY MASS-SPECTROMETRY [J].
KREBS, JF ;
SIUZDAK, G ;
DYSON, HJ ;
STEWART, JD ;
BENKOVIC, SJ .
BIOCHEMISTRY, 1995, 34 (03) :720-723