Septal Bulge and Risk of Paravalvular Leak After Transcatheter Aortic Valve Replacement

被引:1
|
作者
Sanchis, Laura [1 ]
Nijenhuis, Vincent J. [2 ]
Post, Marco C. [2 ]
Van der Heijden, Jan As [2 ]
Rensing, Benno J. [2 ]
Ten Berg, Juerien M. [2 ]
De Kroon, Thom L. [2 ]
Brouwer, Jorn [2 ]
Heijmen, Robin H. [2 ]
Swaans, Martin J. [2 ]
机构
[1] Hosp Clin Barcelona, Cardiovasc Clin Inst, Barcelona, Spain
[2] St Antonius Hosp, Cardiol Dept, Nieuwegein, Netherlands
来源
STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM | 2019年 / 3卷 / 04期
关键词
Ventricular septum; aortic valve stenosis; transesophageal echocardiography; transcatheter aortic valve replacement;
D O I
10.1080/24748706.2019.1605466
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Proximal septal bulge (SB) is a subaortic protuberance of the interventricular septum into the left ventricular outflow tract (LVOT) without extension to the middle and distal septum. Our aim was to evaluate the impact of SB presence on the incidence of paravalvular leak (PVL) after transcatheter aortic valve replacement (TAVR) in a hypothesis-generating study. Methods: Patients who underwent TAVR in a single center were screened. Those patients with non self-expanding devices with annular leaflet position (Edward Sapien, Lotus) or self-expanding prosthesis and supra-annular leaflet design (Evolut, CoreValve) were included; devices in the early learning curve were excluded. Transesophageal echocardiography (TOE) images performed during TAVR were reviewed and SB nonstandard measurements were obtained from LVOT view. The presence of PVL was evaluated in the TOE immediately after TAVR. ANOVA and Bonferroni statistical tests were used to compare quantitative variables among groups. Results: We included 147 patients (mean age 78 12 years, 59% females). The implanted devices were: 33 Evolut R, 56 CoreValve, 41 Lotus Valve and 17 Edwards Sapien. There were no significant differences between SB parameters among the different devices. Maximal SB thickness in the LVOT was related to PVL grade in the self-expanding valves. Moderate-severe PVL was less frequently observed in the non self-expanding devices group (2.4%), the differences among this group were not significant. Conclusions: The presence of a prominent SB in the LVOT could be related to a higher risk of PVL, likely in self-expandable devices with supra-annular leaflet position.
引用
收藏
页码:329 / 333
页数:5
相关论文
共 50 条
  • [1] Septal Bulge and Risk of Paravalvular Leak After Transcatheter Aortic Valve Replacement (vol 3, pg 329, 2019)
    Sanchis, Laura
    Nijenhuis, Vincent J.
    Post, Marco C.
    Van der Heijden, Jan As
    Rensing, Benno J.
    Ten Berg, Jurien M.
    De Kroon, Thom L.
    Brouwer, Jorn
    Heijmen, Robin H.
    Swaans, Martin J.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2020, 4 (06): : W541 - W541
  • [2] Paravalvular leak after transcatheter aortic valve replacement
    Genereux, P.
    Kodali, S.
    Hahn, R.
    Nazif, T.
    Williams, M. R.
    Leon, M. B.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (05): : 529 - 537
  • [3] Risk factors for paravalvular leak after transcatheter aortic valve replacement
    Pollari, Francesco
    Dell'Aquila, Angelo Maria
    Soehn, Claudius
    Marianowicz, Jill
    Wiehofsky, Pia
    Schwab, Johannes
    Pauschinger, Matthias
    Hitzl, Wolfgang
    Fischlein, Theodor
    Pfeiffer, Steffen
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (04): : 1406 - +
  • [4] Paravalvular Aortic Leak After Transcatheter Aortic Valve Replacement Current Knowledge
    Lerakis, Stamatios
    Hayek, Salim S.
    Douglas, Pamela S.
    CIRCULATION, 2013, 127 (03) : 397 - 407
  • [5] TEMPORAL CHANGE OF PARAVALVULAR LEAK AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Ko, Tsung-Yu
    Lin, Mao-Shin
    Kao, Hsien-Li
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1148 - 1148
  • [6] Techniques and outcomes of paravalvular leak repair after transcatheter aortic valve replacement
    Waterbury, Thomas M.
    Reeder, Guy S.
    Pislaru, Sorin V.
    Cabalka, Allison K.
    Rihal, Charanjit S.
    Eleid, Mackram F.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (05) : 870 - 877
  • [7] Risk factors for paravalvular leak after transcatheter aortic valve implantation
    Wilczek, Krzysztof
    Bujak, Kamil
    Regula, Rafal
    Chodor, Piotr
    Osadnik, Tadeusz
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2015, 12 (02): : 89 - 94
  • [8] Paravalvular leak after transcatheter aortic valve implantation
    Gokalp, Orhan
    Iner, Hasan
    Besir, Yuksel
    Yesilkaya, Nihan Karakas
    Yilik, Levent
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2020, 24 (03): : 210 - 211
  • [9] Paravalvular leak after transcatheter aortic valve replacement: Avoid it or treat it if you can!
    Kumar, Arnav
    Block, Peter C.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) : 981 - 982
  • [10] Mixed aortic valve disease: association with paravalvular leak and reduced survival after transcatheter aortic valve replacement
    Demirel, Caglayan
    Winter, Max Paul
    Nitsche, Christian
    Koschatko, Sophia
    Jantsch, Charlotte
    Mascherbauer, Katharina
    Halavina, Kseniya
    Heitzinger, Gregor
    Dona, Carolina
    Dannenberg, Varius
    Spinka, Georg
    Koschutnik, Matthias
    Andreas, Martin
    Hengstenberg, Christian
    Bartko, Philipp E.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (05) : 718 - 726