A new high resolution radioimager for the quantitative analysis of radiolabelled molecules in tissue section

被引:36
作者
Laniece, P [1 ]
Charon, Y
Cardona, A
Pinot, L
Maitrejean, S
Mastrippolito, R
Sandkamp, B
Valentin, L
机构
[1] CNRS, Inst Phys Nucl, Orsay, France
[2] Univ Paris 07, Phys Nucl Lab, Paris, France
[3] Inst Pasteur, CNRS, Lab Technol Cellulaire, Paris, France
[4] Ecole Super Phys & Chim Ind, Paris, France
关键词
radioimaging; quantification; autoradiography; receptor binding; in situ hybridization; intensified CCD;
D O I
10.1016/S0165-0270(98)00128-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a high-speed, high-resolution imager of beta particles. It is devoted to be used in autoradiography experiments such as receptor binding or in situ hybridization experiments, either instead of, or in complement with autoradiographic film and emulsions. It allows the user to locate and perform quantitative analyses of (H-3, C-14, S-35, P-33, P-32, I-125) labelled molecules with a 15 mu m spatial resolution on a 0.9 x 1.3 cm(2) sensitive area. Combining recent techniques (specific scintillator thin sheets and intensified charge-coupled device (CCD)) this imager offers a wide dynamic range and real-time acquisition. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 18 条
  • [1] Quantitative nuclear imaging in biology
    Charon, Y
    Laniece, P
    Mastrippolito, R
    Siebert, R
    Tricoire, H
    Valentin, L
    [J]. ANNALES DE PHYSIQUE, 1997, 22 (06) : 707 - 770
  • [2] A SELF TRIGGERED INTENSIFIED CCD (STIC)
    CHARON, Y
    LANIECE, P
    BENDALI, M
    GAILLARD, JM
    LEBLANC, M
    MASTRIPPOLITO, R
    TRICOIRE, H
    VALENTIN, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) : 379 - 384
  • [3] CHARON Y, 1990, Patent No. 10593
  • [4] OPTICAL IMAGING OF THE SPATIAL-DISTRIBUTION OF BETA-PARTICLES EMERGING FROM SURFACES
    CHARPAK, G
    DOMINIK, W
    ZAGANIDIS, N
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (06) : 1741 - 1745
  • [5] Radioimagers as an alternative to film autoradiography for in situ quantitative analysis of I-125-ligand receptor binding and pharmacological studies
    CrumeyrolleArias, M
    JafarianTehrani, M
    Cardona, A
    Edelman, L
    Roux, P
    Laniece, P
    Charon, Y
    Haour, F
    [J]. HISTOCHEMICAL JOURNAL, 1996, 28 (11): : 801 - 809
  • [6] IN-SITU CHARACTERIZATION OF GNRH RECEPTORS - USE OF 2 RADIOIMAGERS AND COMPARISON WITH QUANTITATIVE AUTORADIOGRAPHY
    CRUMEYROLLEARIAS, M
    LATOUCHE, J
    LANIECE, P
    CHARON, Y
    TRICOIRE, H
    VALENTIN, L
    ROUX, P
    MIRAMBEAU, G
    LEBLANC, P
    FILLION, G
    HAOUR, F
    [J]. JOURNAL OF RECEPTOR RESEARCH, 1994, 14 (3-4): : 251 - 265
  • [7] A NOVEL QUANTITATIVE RECEPTOR AUTORADIOGRAPHY AND IN-SITU HYBRIDIZATION HISTOCHEMISTRY TECHNIQUE USING STORAGE PHOSPHOR SCREEN IMAGING
    ITO, T
    SUZUKI, T
    LIM, DK
    WELLMAN, SE
    HO, IK
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1995, 59 (02) : 265 - 271
  • [8] AUTORADIOGRAPHY USING STORAGE PHOSPHOR TECHNOLOGY
    JOHNSTON, RF
    PICKETT, SC
    BARKER, DL
    [J]. ELECTROPHORESIS, 1990, 11 (05) : 355 - 360
  • [9] QUANTITATIVE RECEPTOR MAPPING BY AUTORADIOGRAPHY - SOME CURRENT TECHNICAL PROBLEMS
    KUHAR, MJ
    UNNERSTALL, JR
    [J]. TRENDS IN NEUROSCIENCES, 1985, 8 (02) : 49 - 53
  • [10] KUHAR MJ, 1990, METHODS NEUROTRANSMI, P177