Applicability of Near-Infrared Spectroscopy to Measure Cerebral Autoregulation Noninvasively in Neonates: A Validation Study in Piglets

被引:23
作者
Hahn, Gitte H. [1 ]
Heiring, Christian [2 ]
Pryds, Ole [3 ]
Greisen, Gorm [1 ]
机构
[1] Univ Copenhagen Hosp, Dept Neonatol, Rigshosp, DK-2100 Copenhagen, Denmark
[2] Hillerod Hosp, Dept Pediat, DK-3400 Hillerod, Denmark
[3] Copenhagen Univ Hosp, Hvidovre Hosp, Dept Pediat, DK-2650 Hvidovre, Denmark
关键词
PRETERM INFANTS; BLOOD-FLOW; IMPAIRED AUTOREGULATION; PRESSURE-PASSIVITY; PREMATURE-INFANTS; NEWBORN; VASOREACTIVITY; HETEROGENEITY; MODEL; RAT;
D O I
10.1203/PDR.0b013e3182231d9e
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Impaired cerebral autoregulation (CA) is common and is associated with brain damage in sick neonates. Frequency analysis using spontaneous changes in arterial blood pressure (ABP) and cerebral near-infrared spectroscopy (NIRS) has been used to measure CA in several clinical studies. Coherence of the NIRS and ABP signals (i.e. correlation in the frequency domain) detects impairment of CA, whereas gain (i.e. magnitude of ABP variability passing from systemic to cerebral circulation) estimates the degree of this impairment. So far, however, this method has not been validated. In 12 newborn piglets, we compared NIRS-derived measures of CA with a conventional measure of CA: cerebral blood flow was measured by laser Doppler flowmetry, and changes in ABP were induced by inflating a thoracic aorta balloon. CA capacity was calculated as %Delta CVR/%Delta ABP (i.e. percentage of full autoregulatory capacity), where CVR (i.e. cerebral vascular resistance) was estimated as ABP/Doppler flux. Correlation between coherence and CA capacity (r = -0.34, n = 24, p > 0.05) and between gain and CA capacity (r = -0.11, n = 24, p > 0.05) was limited. As expected, however, gain was significantly associated with CA capacity in measurements with significant coherence (r = -0.55, n = 15, p = 0.03). In conclusion, our data validate frequency analysis for estimation of CA in clinical research. Low precision, however, hampers its clinical application. (Pediatr Res 70: 166-170, 2011)
引用
收藏
页码:166 / 170
页数:5
相关论文
共 24 条
[1]  
Armstead WM, 2000, MICROCIRCULATION, V7, P225, DOI 10.1080/713773978
[2]   REGIONAL, SEGMENTAL, AND TEMPORAL HETEROGENEITY OF CEREBRAL VASCULAR AUTO-REGULATION [J].
BAUMBACH, GL ;
HEISTAD, DD .
ANNALS OF BIOMEDICAL ENGINEERING, 1985, 13 (3-4) :303-310
[3]   Dynamic cerebral autoregulation in sick newborn infants [J].
Boylan, GB ;
Young, K ;
Panerai, RB ;
Rennie, JM ;
Evans, DH .
PEDIATRIC RESEARCH, 2000, 48 (01) :12-17
[4]   Continuous time-domain analysis of cerebrovascular autoregulation using near-infrared spectroscopy [J].
Brady, Ken M. ;
Lee, Jennifer K. ;
Kibler, Kathleen K. ;
Smielewski, Piotr ;
Czosnyka, Marek ;
Easley, R. Blaine ;
Koehler, Raymond C. ;
Shaffner, Donald H. .
STROKE, 2007, 38 (10) :2818-2825
[5]   Not All Models Are Created Equal: Animal Models to Study Hypoxic-Ischemic Encephalopathy of the Newborn Commentary on Gelfand SL et al.: A New Model of Oxidative Stress in Rat Pups (Neonatology 2008; 94: 293-299) [J].
Chapados, Isabelle ;
Cheung, Po-Yin .
NEONATOLOGY, 2008, 94 (04) :300-303
[6]  
Elwell CE, 1997, ADV EXP MED BIOL, V428, P561
[7]   THE FREQUENCY-DEPENDENT BEHAVIOR OF CEREBRAL AUTOREGULATION [J].
GILLER, CA .
NEUROSURGERY, 1990, 27 (03) :362-368
[8]  
Greisen G, 2007, NEOREVIEWS, V8, pe22
[9]   To Autoregulate or Not to Autoregulate-That is No Longer the Question [J].
Greisen, Gorm .
SEMINARS IN PEDIATRIC NEUROLOGY, 2009, 16 (04) :207-215
[10]   Precision of coherence analysis to detect cerebral autoregulation by near-infrared spectroscopy in preterm infants [J].
Hahn, Gitte Holst ;
Christensen, Karl Bang ;
Leung, Terence S. ;
Greisen, Gorm .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (03)