The Effect of Respiration on Breast Measurement Using Three-dimensional Breast Imaging

被引:14
作者
Wang, Chenglong [1 ,2 ]
Liu, Chunjun [1 ,2 ]
Giatsidis, Giorgio [3 ,4 ]
Cheng, Hao [1 ,2 ]
Chen, Lin [1 ,2 ]
Kang, Deni [1 ,2 ]
Panayi, Adriana C. [3 ,4 ]
Luan, Jie [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Plast Surg Hosp, Dept Aesthet & Reconstruct Breast Surg, 33 Ba Da Chu Rd, Beijing 100144, Peoples R China
[2] Peking Union Med Coll, 33 Ba Da Chu Rd, Beijing 100144, Peoples R China
[3] Brigham & Womens Hosp, Dept Surg, Div Plast Surg, Tissue Engn & Wound Healing Lab, 75 Francis St, Boston, MA 02115 USA
[4] Harvard Med Sch, Boston, MA USA
关键词
Three-dimensional imaging; Exhalation; Inhalation; Breast morphology; Breast volume; Mammaplasty; SCANNING TECHNIQUE; VOLUMETRIC CHANGE; AUGMENTATION; SHAPE;
D O I
10.1007/s00266-018-1231-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundThree-dimensional (3D) imaging offers new opportunities to enable objective and quantitative analysis of the breast. Unlike scanning of rigid objects, respiration may be one of the factors that can influence the measurement of breast when using 3D imaging. In this study, we aimed to investigate how the different respiratory phases affect 3D morphologic and volumetric evaluations of the breast.MethodsWe performed preoperative 3D breast imaging at the end of expiration (EE) and the end of inspiration (EI). We repeated scans on each respiratory phase, taking four scans in total (EE1, EE2 and EI1, EI2). Using Geomagic Studio 12 software, measurements from the different respiratory phases (EE1 and EI1) were compared for differences in the linear distances of breast. Breast volumetric change error (BVCE) was measured between EE1 and EE2 (R1) and between EI1 and EI2 (R2). A multilevel model was used to analyze the difference of linear-distances parameters between EE1 and EI1 and a paired sample t-test was used to analyze the difference between R1 and R2.ResultsOur study included 13 Chinese women (26 breasts) with a mean age of 32.66.3years. Compared with EI, EE showed a longer sternal notch to the level of the inframammary fold and shorter nipple to midline (p<0.05). During EI, breast projection increased by 0.23cm (95% CI -0.39, -0.08) and breast base width increased by 0.27cm (95% CI -0.46, -0.09). The position of the nipple moved by 0.18cm (95% CI -0.34, -0.03) laterally, 0.41cm (95% CI 0.18, 0.64) cranially, and 0.71cm (95% CI -0.92, -0.51) anteriorly. Although there was no significant difference in BVCE between EE and EI, the result seen with EE appeared to be more consistent.ConclusionsThe results of this study demonstrate that there was no difference in breast volume results when patients are in the expiratory or inspiratory state during 3D breast imaging. This study, however, holds potential benefits to both surgical practice as well as the 3D imaging industry.Level of Evidence IV p id=Par5 This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [41] Validation of the Vectra XT three-dimensional imaging system for measuring breast volume and symmetry following oncological reconstruction
    Rachel L. O’Connell
    Komel Khabra
    Jeffrey C. Bamber
    Nandita deSouza
    Farid Meybodi
    Peter A. Barry
    Jennifer E. Rusby
    Breast Cancer Research and Treatment, 2018, 171 : 391 - 398
  • [42] Three-dimensional virtual reality in surgical planning for breast cancer with reconstruction
    De la Cruz-ku, Gabriel
    Mallouh, Michael P.
    Roman, Jr Smith Torres
    Linshaw, David
    SAGE OPEN MEDICAL CASE REPORTS, 2023, 11
  • [43] Three-dimensional imaging characteristics and depth resolution in digital holographic three-dimensional imaging spectrometry
    Obara, Masaki
    Yoshimori, Kyu
    INTERNATIONAL CONFERENCE ON PHOTONICS SOLUTIONS 2015, 2015, 9659
  • [44] Automated Measurement of Intracranial Volume Using Three-Dimensional Photography
    Tu, Liyun
    Porras, Antonio R.
    Enquobahrie, Andinet
    Buck, Graham C.
    Tsering, Deki
    Horvath, Samantha
    Keating, Robert
    Oh, Albert K.
    Rogers, Gary F.
    George Linguraru, Marius
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (03) : 314E - 323E
  • [45] Three-Dimensional Electromagnetic Torso Imaging Using Reconfigurable Antennas
    Zamani, Ali
    Darvazehban, Amin
    Rezaeieh, Sasan Ahdi
    Abbosh, Amin
    2019 13TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2019,
  • [46] Performance Analysis of Three-Dimensional Measurement Algorithm with Focus Variation Microscopic Imaging
    Shi Yanqiong
    Ying Qiuxia
    Lu Rongsheng
    LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (07)
  • [47] Initial Assessment of VECTRA Three-Dimensional Imaging to Accurately Simulate Breast Volume Changes in Transfeminine Patients: A Mannequin Study
    Lopez, Ximena
    Panton, Jasmine
    Nagarkar, Purushottam
    Preston, Stephanie
    Abramowitz, Jessica
    Amirlak, Bardia
    AESTHETIC SURGERY JOURNAL OPEN FORUM, 2023, 5
  • [48] Three-dimensional Assessment of the Breast: Validation of a Novel, Simple and Inexpensive Scanning Process
    Oranges, Carlo M.
    Madduri, Srinivas
    Brantner, Philipp
    Msallem, Bilal
    Giordano, Salvatore
    Benitez, Benito
    Kalbermatten, Daniel F.
    Schaefer, Dirk J.
    Thieringer, Florian M.
    IN VIVO, 2019, 33 (03): : 839 - 842
  • [49] Three-dimensional imaging of the pediatric airway
    Nicotra, JJ
    Mahboubi, S
    Kramer, SS
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 1997, 41 (03) : 299 - 305
  • [50] Three-dimensional evaluation of breast volume changes following autologous free flap breast reconstruction over six months
    Wilting, Floor N. H.
    Hameeteman, Marijn
    Tielemans, Hanneke J. P.
    Ulrich, Dietmar J. O.
    Hummelink, Stefan
    BREAST, 2020, 50 : 85 - 94