Bi-cell surface plasmon resonance detection of aptamer mediated thrombin capture in serum

被引:30
作者
Mani, Rinosh Joshua
Dye, Roman G.
Snider, Timothy A.
Wang, Shaopeng [2 ]
Clinkenbeard, Kenneth D. [1 ]
机构
[1] Oklahoma State Univ, Coll Vet Med, Ctr Vet Hlth Sci, Dept Vet Pathobiol, Stillwater, OK 74078 USA
[2] ICx Normad Inc, Stillwater, OK 74074 USA
关键词
Thrombin; Serum; Aptamer; Bi-cell surface plasmon resonance; spectrometer; DNA APTAMERS; REAL-TIME; SPECTROSCOPY; OLIGONUCLEOTIDE; IMMUNOSENSOR; BIOSENSOR; ANTIGEN; BINDING;
D O I
10.1016/j.bios.2011.05.049
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The serine protease coagulation factor thrombin functions primarily in hemostasis, but is also involved in atherosclerosis, thromboembolic disease, cancer and inflammatory disease. Direct measurement of coagulation proteins including thrombin in plasma samples poses a significant challenge because of lack of specific probes and low thrombin concentrations. In addition, high plasma protein concentrations in samples can result in high backgrounds. These challenges were overcome using a bi-cell surface plasmon resonance (SPR) spectrometer with an immobilized thrombin aptamer to measure thrombin in samples passed through a low volume flow cell. For thrombin in Tris-EDTA buffer, the limit of detection CLOD) was 25 nM. Coefficient of variation (CV) for detection of 50 nM was 12.2% and 12.4% for intra and inter-day measurements respectively. This detection was specific for both thrombin aptamer and for thrombin. Using serum samples spiked with thrombin, the LOD was 50 nM with a linear range of detection from 50 nM to 200 nM. However use of serum samples was associated with consistent, low-level background drift. The contributions of nonspecific protein absorption onto the sensor surface and sample flow speed were assessed, and strategies to reduce this background drift were explored. We conclude that the bi-cell SPR platform with an aptamer capture probe can be employed as a highly sensitive real-time, label-free biosensor for the detection of coagulation factors in plasma samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4832 / 4836
页数:5
相关论文
共 35 条
[1]   Aptasensor development: Elucidation of critical parameters for optimal aptamer performance [J].
Baldrich, E ;
Restrepo, A ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7053-7063
[2]   Analytical performances of aptamer-based sensing for thrombin detection [J].
Bini, Alessandra ;
Minunni, Maria ;
Tombelli, Sara ;
Centi, Sonia ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :3016-3019
[3]   SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN [J].
BOCK, LC ;
GRIFFIN, LC ;
LATHAM, JA ;
VERMAAS, EH ;
TOOLE, JJ .
NATURE, 1992, 355 (6360) :564-566
[4]   Real-Time, label-free monitorine, of tumor antigen and serum antibody interactions [J].
Campagnolo, C ;
Meyers, KJ ;
Ryan, T ;
Atkinson, RC ;
Chen, YT ;
Scanlan, MJ ;
Ritter, G ;
Old, LJ ;
Batt, CA .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 61 (03) :283-298
[5]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[6]   Proximity extension of circular DNA aptamers with real-time protein detection [J].
Di Giusto, DA ;
Wlassoff, WA ;
Gooding, JJ ;
Messerle, BA ;
King, GC .
NUCLEIC ACIDS RESEARCH, 2005, 33 (06) :1-7
[7]   The development and application of a surface plasmon resonance-based inhibition immunoassay for the determination of warfarin in plasma ultrafiltrate [J].
Fitzpatrick, B ;
O'Kennedy, R .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 291 (1-2) :11-25
[8]   Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin [J].
Gobi, K. Vengatajalabathy ;
Iwasaka, Hiroyuki ;
Miura, Norio .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1382-1389
[9]   INVIVO ANTICOAGULANT PROPERTIES OF A NOVEL NUCLEOTIDE-BASED THROMBIN INHIBITOR AND DEMONSTRATION OF REGIONAL ANTICOAGULATION IN EXTRACORPOREAL CIRCUITS [J].
GRIFFIN, LC ;
TIDMARSH, GF ;
BOCK, LC ;
TOOLE, JJ ;
LEUNG, LLK .
BLOOD, 1993, 81 (12) :3271-3276
[10]   Thrombin generation, a function test of the haemostatic-thrombotic system [J].
Hemker, H. Coenraad ;
Al Dieri, Raed ;
De Smedt, Erik ;
Beguin, Suzette .
THROMBOSIS AND HAEMOSTASIS, 2006, 96 (05) :553-561