Can the method of fixation influence the wear behaviour of ZrN coated unicompartmental mobile knee prostheses?

被引:6
作者
Affatato, S. [1 ]
Spinelli, M. [1 ]
Lopomo, N. [2 ]
Grupp, T. M. [3 ,4 ]
Marcacci, M. [2 ]
Toni, A.
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Lab Biomeccan, I-40136 Bologna, Italy
[3] Aesculap AG Res & Dev, Tuttlingen, Germany
[4] Univ Munich, Clin Orthopaed Surg, Munich, Germany
关键词
Mobile-bearing; Fixed-bearing; UKP; Knee simulator; Polyethylene menisci; ZrN coating; IN-VITRO WEAR; ANTERIOR CRUCIATE LIGAMENT; FIXED-BEARING; PVD TECHNIQUES; FOLLOW-UP; ARTHROPLASTY; REPLACEMENT; KINEMATICS; POLYETHYLENE; CONTACT;
D O I
10.1016/j.clinbiomech.2010.09.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Modern unicompartmental knee prostheses represent a valid alternative to total knee replacement. It is known that variations in clinical alignment lead to altered biomechanics and abnormal wear. The aim of this study was to assess the influence, on wear behaviour, of two different cementing interfaces of the femoral components tested on a knee joint wear simulator. Methods: The wear tests were run in a knee wear simulator at a frequency of 1.1 Hz for 3 million cycles in accordance with ISO 14243-3. Twelve commercial mobile CUR 1020 UHMWPE meniscus specimens articulated in between 12 cobalt-chromium-molybdenum alloy femoral and tibial components covered by a multi-layer of chromium nitride and a final layer of zirconium nitride ceramic coating to prevent ion release from the substrate. Two wear tests were performed: in the first test, each femoral component was cemented into a custom made metallic-block shaped to perfectly host it. In the second test, synthetic composite femurs received the femoral components on the basis of guidelines used in current surgery. Findings: The two cementing interfaces showed a significantly different wear behaviour, quantified as mean weight loss (P < 0.001). Scanning electron microscope examinations of new and tested metallic components showed macro- and micro-pores of few microns on both configurations. Interpretation: The wear pattern observed at 3 million cycles showed differences between the two methods of fixation for the meniscus femoral components. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 45 条
[1]   Unicompartmental knee prostheses:: in vitro wear assessment of the menisci tibial insert after two different fixation methods [J].
Affatato, S. ;
Spinelli, M. ;
Zavalloni, M. ;
Carmignato, S. ;
Lopomo, N. ;
Marcacci, M. ;
Viceconti, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :5357-5369
[2]   The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints [J].
Affatato, S ;
Bersaglia, G ;
Yin, JQ ;
Traina, F ;
Toni, A ;
Viceconti, M .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H3) :457-464
[3]   Fluid absorption study in ultra-high molecular weight polyethylene( UHMWPE) sterilized and unsterilized acetabular cups [J].
Affatato, S ;
Vandelli, C ;
Bordini, B ;
Toni, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H1) :107-111
[4]  
Bader R, 2008, ORTHOPADE, V37, P136, DOI 10.1007/s00132-007-1189-x
[5]   Comparing in vivo kinematics of unicondylar and bi-unicondylar knee replacements [J].
Banks, SA ;
Fregly, BJ ;
Boniforti, F ;
Reinschmidt, C ;
Romagnoli, S .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (07) :551-556
[6]   Characterisation of chromium nitride films produced by PVD techniques [J].
Barata, A ;
Cunha, L ;
Moura, C .
THIN SOLID FILMS, 2001, 398 :501-506
[7]   Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics [J].
Benson, LC ;
DesJardins, JD ;
LaBerge, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :496-504
[8]   Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses [J].
Biau, D. ;
Mullins, M. M. ;
Judet, T. ;
Piriou, P. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (10) :927-933
[9]   Mobile-bearing knee replacement - Concepts and results [J].
Callaghan, JJ ;
Insall, JN ;
Greenwald, AS ;
Dennis, DA ;
Komistek, RD ;
Murray, DW ;
Bourne, RB ;
Rorabeck, CH ;
Dorr, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (07) :1020-1041
[10]  
Calonius O, 2002, CLIN ORTHOP RELAT R, P219