The Association Between Mucin Balls and Corneal Infiltrative Events During Extended Contact Lens Wear

被引:17
作者
Szczotka-Flynn, Loretta [1 ,2 ]
Benetz, Beth Ann [1 ,2 ]
Lass, Jonathan [1 ,2 ]
Albright, Matthew [1 ,2 ]
Gillespie, Beth [1 ,2 ]
Kuo, Jana [1 ,2 ]
Fonn, Desmond [3 ]
Sethi, Ajay [4 ]
Rimm, Alfred [5 ]
机构
[1] Case Western Reserve Univ, Dept Ophthalmol & Visual Sci, Cleveland, OH 44106 USA
[2] Univ Hosp Eye Inst, Cleveland, OH 44106 USA
[3] Univ Waterloo, Sch Optometry, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
[4] Univ Wisconsin, Dept Populat Hlth Sci, Madison, WI USA
[5] Case Western Reserve Univ, Dept Epidemiol & Biostat, Cleveland, OH 44106 USA
关键词
contact lens; mucin balls; corneal infiltrative event; continuous wear; silicone hydrogel; PSEUDOMONAS-AERUGINOSA ADHERENCE; SILICONE-HYDROGEL; RISK-FACTORS; SURFACE; EYE; DEPOSITION; MUCUS; MICE; VIVO;
D O I
10.1097/ICO.0b013e3181fb8644
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the association between mucin ball formation and corneal infiltrative events (CIEs) during continuous wear with lotrafilcon A silicone hydrogel contact lenses. Methods: Subjects (n = 205) in the Longitudinal Analysis of Silicone Hydrogel Contact Lens Study wore lotrafilcon A contact lenses for 12 months of continuous wear. The primary outcome was a CIE. Kaplan-Meier methods were used to estimate the unadjusted cumulative incidence of remaining CIE free stratified by mucin ball presence. Cox proportional hazards regression was used to model the hazard of developing a CIE as a function of mucin ball formation and other covariates. Results: Over half (54.2%) of the subjects displayed some presence of mucin balls during at least 1 visit and about one third (32.8%) displayed repeated episodes. Mucin ball scores were correlated between the 2 eyes and weakly correlated with corneal curvature (P <= 0.005). Univariate analyses revealed that the relative hazard for a CIE was 0.35 [95% confidence interval (CI), 0.19-0.68] if a single episode of mucin balls was detected and 0.17 (95% CI, 0.06-0.43) if repeated episodes were detected. Upon multivariate analysis, repeated presence of mucin balls was associated with an 84% decreased hazard of experiencing a CIE (hazard ratio: 0.16; 95% CI, 0.06-0.44). Conclusions: The presence of mucin balls is significantly associated with a decreased incidence of CIEs, and the effect is greatest when they are repeatedly present over time. We hypothesize that the mucin ball presence represents a more concentrated or viscous mucus layer, which prevents upregulation of the immune response against bacterial ligands.
引用
收藏
页码:535 / 542
页数:8
相关论文
共 45 条
[1]   Corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study: Baseline prevalence and repeatability of detection [J].
Barr, JT ;
Schechtman, KB ;
Fink, BA ;
Pierce, GE ;
Pensyl, CD ;
Zadnik, K ;
Gordon, MO .
CORNEA, 1999, 18 (01) :34-46
[2]   Patterns of mucin adherence to contact lenses [J].
Berry, M ;
Harris, A ;
Corfield, AP .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (02) :567-572
[3]   Commensal ocular bacteria degrade mucins [J].
Berry, M ;
Harris, A ;
Lumb, R ;
Powell, K .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (12) :1412-1416
[4]   Mucins and Ocular Signs in Symptomatic and Asymptomatic Contact Lens Wear [J].
Berry, Monica ;
Pult, Heiko ;
Purslow, Christine ;
Murphy, Paul J. .
OPTOMETRY AND VISION SCIENCE, 2008, 85 (10) :930-938
[5]   Release of membrane-associated mucins from ocular surface epithelia [J].
Blalock, Timothy D. ;
Spurr-Michaud, Sandra J. ;
Tisdale, Ann S. ;
Gipson, Ilene K. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (05) :1864-1871
[6]   Ex Vivo Protein Deposition on Bi-Weekly Silicone Hydrogel Contact Lenses [J].
Boone, Adrienne ;
Heynen, Miriam ;
Joyce, Elizabeth ;
Varikooty, Jalaiah ;
Jones, Lyndon .
OPTOMETRY AND VISION SCIENCE, 2009, 86 (11) :1241-1249
[7]  
Bourassa SBW., 1988, INT CONTACT LENS CLI, V15, P338
[8]   Lens adherence and postlens tear film changes in closed-eye wear of hydrogel lenses [J].
Bruce, AS ;
Mainstone, JC .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) :28-34
[9]  
Bruce AS., 1992, CLIN EYE VISION CARE, V4, P111
[10]  
CARNT NKL, 2007, ARVO ANN M