共 5 条
Right Lobe Estimated Blood-free Weight for Living Donor Liver Transplantation: Accuracy of Automated Blood-free CT Volumetry-Preliminary Results
被引:43
|作者:
Kim, Kyoung Won
[1
]
Lee, Jeongjin
[3
]
Lee, Ho
[4
]
Jeong, Woo Kyoung
[5
]
Won, Hyung Jin
[1
]
Shin, Yong Moon
[1
]
Jung, Dong-Hwan
[2
]
Park, Jeong Ik
[6
]
Song, Gi-Won
[2
]
Ha, Tae-Yong
[2
]
Moon, Deok-Bog
[2
]
Kim, Ki-Hun
[2
]
Ahn, Chul-Soo
[2
]
Hwang, Shin
[2
]
Lee, Sung-Gyu
[2
]
机构:
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Liver Transplantat Surg, Seoul 138736, South Korea
[3] Catholic Univ Korea, Dept Digital Media, Gyeonggi Do, South Korea
[4] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
[5] Hanyang Univ, Dept Radiol, Guri Hosp, Guri, South Korea
[6] Inje Univ, Coll Med, Dept Surg, Busan Paik Hosp, Pusan, South Korea
来源:
关键词:
3-DIMENSIONAL COMPUTED-TOMOGRAPHY;
GRAFT VOLUME;
SIZE;
SEGMENTATION;
PREDICTION;
IMPACT;
D O I:
10.1148/radiol.10091897
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To determine the relative accuracy of automated blood-free to blood-filled computed tomographic (CT) volumetry for estimation of right-lobe weight in living donor liver transplantation. Materials and Methods: This retrospective study was approved by the institutional review board; informed consent was waived. Between October 1, 2008, and April 30, 2009, 88 live liver donors 54 men, 34 women; mean age, 26.1 years +/- 6.9 [standard deviation]) who underwent CT and had their right lobes procured in the study institution were included. Automated measurement of blood-filled volume (V(BFill)) and blood-free volume (V(BFree)) of the right lobe was performed by using 16-row multidetector CT performed with 5-mm intervals. Actual hepatic weight was measured blood free during surgery. Percentage blood volume, %V(B), was calculated as follows: %V(B) = V(BFill) - V(BFree)/V(BFill) . 100. Pearson tests were performed to determine correlation coefficients between V(BFill)/1.22 or V(BFree) and weight. Percentage deviation and percentage absolute deviation of V(BFree) from weight were compared with those of V B(Fill)/1.22 by using a paired t test or Wilcoxon rank sum test. Regression analysis was performed between V(BFree) and weight. Results: Mean V(BFill), V(BFree), and weight were 789.0 mL +/- 126.4, 713.9 mL +/- 114.4, and 717.8 g +/- 110.4. Percentage blood volume varied from 6.5% to 19.8% (mean, 9.5%). Compared with weight, the correlation coefficient was slightly higher with V(BFree) (r = 0.9140) than with V(BFill)/1.22 (r = 0.8909). Mean percentage deviation and percentage absolute deviation were significantly smaller with V(BFree) (-0.4% +/- 6.3, 5.0% +/- 3.8; P < .001) than with V(BFill)/1.22 (-9.8% +/- 6.5, 10.2% +/- 7.3; P < .001). The equation relating V(BFree) and weight, W, was as follows: W = (0.8815 . V(BFree)) + 88.5117, with R(2) of 0.8355 (P < .001). Conclusion: At automated CT volumetry in live liver donors, the percentage blood volume varies. The V(BFree) is more accurate than is V(BFill)/1.22 in estimation of hepatic weight. (C) RSNA, 2010
引用
收藏
页码:433 / 440
页数:8
相关论文