Midterm follow-up after implantation of a polyurethane meniscal scaffold for segmental medial meniscus loss: maintenance of good clinical and MRI outcome

被引:44
作者
Schuttler, Karl F. [1 ]
Haberhauer, Felix [1 ]
Gesslein, Markus [2 ]
Heyse, Thomas J. [1 ]
Figiel, Jens [3 ]
Lorbach, Olaf [4 ]
Efe, Turgay [1 ]
Roessler, Philip P. [1 ,5 ]
机构
[1] Univ Hosp Marburg, Dept Orthoped & Rheumatol, Baldingerstr, D-35043 Marburg, Germany
[2] Paracelcus Med Univ, Dept Trauma & Orthoped Surg, Nurnberg, Germany
[3] Univ Hosp Marburg, Dept Diagnost & Intervent Radiol, D-35043 Marburg, Germany
[4] Univ Saarland, Dept Orthoped Surg, Homburg, Saar, Germany
[5] Univ Hosp Bonn, Dept Orthoped & Trauma Surg, Bonn, Germany
关键词
Actifit; Meniscus; Biodegradable scaffold; MRI; Polyurethane scaffold; Partial meniscectomy; Irreparable meniscal defect; LONG-TERM OUTCOMES; PARTIAL MENISCECTOMY; KNEE; OSTEOARTHRITIS;
D O I
10.1007/s00167-015-3759-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The preservation of meniscal structure and function after segmental meniscal loss is of crucial importance to prevent early development of osteoarthritis. Implantation of artificial meniscal implants has been reported as a feasible treatment option. The purpose of this study was to assess the clinical and magnetic resonance imaging (MRI) results 4 years after implantation of a polyurethane scaffold for chronic segmental medial meniscus deficiency following partial medial meniscectomy. Eighteen patients received arthroscopic implantation of an Actifit(A (R)) polyurethane meniscal implant (Orteq Sports Medicine, London, UK) for deficiency of the medial meniscus. Patients were followed at 6, 12, 24, and 48 months. Clinical outcome was assessed using established patient-reported outcome scores (KOOS, KSS, UCLA Activity Scale, VAS for pain). Radiological outcome was quantified by MRI scans after 6, 12, 24, and 48 months evaluating scaffold morphology, tissue integration, and status of the articular cartilage as well as signs of inflammation. Median patient age was 32.5 years (range 17-49 years) with a median meniscal defect size of 44.5 mm (range 35-62 mm). Continuing improvement of the VAS and KSS Knee and Function Scores could be observed after 48 months compared to baseline, whereas improvement of the activity level according to UCLA continued only up to 24 months and decreased from there on. The KOOS Score showed significant improvement in all dimensions. MRI scans showed reappearance of bone bruises in two patients with scaffold extrusion. No significant changes in the articular cartilage could be perceived. Arthroscopic treatment for patients with chronic segmental meniscal loss using a polyurethane meniscal implant can achieve sustainable midterm results regarding pain reduction and knee function. IV.
引用
收藏
页码:1478 / 1484
页数:7
相关论文
共 35 条
[1]   Polyurethane scaffold in lateral meniscus segmental defects: Clinical outcomes at 24 months follow-up [J].
Bouyarmane, H. ;
Beaufils, P. ;
Pujol, N. ;
Bellemans, J. ;
Roberts, S. ;
Spalding, T. ;
Zaffagnini, S. ;
Marcacci, M. ;
Verdonk, P. ;
Womack, M. ;
Verdonk, R. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (01) :153-157
[2]   Long-term outcomes of medial CMI implant versus partial medial meniscectomy in patients with concomitant ACL reconstruction [J].
Bulgheroni, Erica ;
Grassi, Alberto ;
Bulgheroni, Paolo ;
Muccioli, Giulio Maria Marcheggiani ;
Zaffagnini, Stefano ;
Marcacci, Maurilio .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) :3221-3227
[3]   Follow-up of collagen meniscus implant patients: Clinical, radiological, and magnetic resonance imaging results at 5 years [J].
Bulgheroni, Paolo ;
Murena, Luigi ;
Ratti, Chiara ;
Bulgheroni, Erica ;
Ronga, Mario ;
Cherubino, Paolo .
KNEE, 2010, 17 (03) :224-229
[4]   Outside-In Meniscus Repair: The Last 25 Years [J].
Dave, Lee Yee Han ;
Caborn, David N. M. .
SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2012, 20 (02) :77-85
[5]   Two-Year Follow-up Study on Clinical and Radiological Outcomes of Polyurethane Meniscal Scaffolds [J].
De Coninck, Tineke ;
Huysse, Wouter ;
Willemot, Laurent ;
Verdonk, Rene ;
Verstraete, Koenraad ;
Verdonk, Peter .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (01) :64-72
[6]   Partial meniscus substitution with a polyurethane scaffold does not improve outcome after an open-wedge high tibial osteotomy [J].
Eduardo Gelber, Pablo ;
Isart, Anna ;
Ignacio Erquicia, Juan ;
Pelfort, Xavier ;
Tey-Pons, Marc ;
Carlos Monllau, Juan .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (01) :334-339
[7]   The safety and short-term efficacy of a novel polyurethane meniscal scaffold for the treatment of segmental medial meniscus deficiency [J].
Efe, Turgay ;
Getgood, Alan ;
Schofer, Markus D. ;
Fuchs-Winkelmann, Susanne ;
Mann, Dieter ;
Paletta, Juergen R. J. ;
Heyse, Thomas J. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (09) :1822-1830
[8]   Impact of type of meniscal tear on radiographic and symptomatic knee osteoarthritis - A sixteen-year followup of meniscectomy with matched controls [J].
Englund, M ;
Roos, EM ;
Lohmander, LS .
ARTHRITIS AND RHEUMATISM, 2003, 48 (08) :2178-2187
[9]   The Meniscus in Knee Osteoarthritis [J].
Englund, Martin ;
Guermazi, Ali ;
Lohmander, L. Stefan .
RHEUMATIC DISEASE CLINICS OF NORTH AMERICA, 2009, 35 (03) :579-+
[10]   Meniscal scaffolds: results and indications. A systematic literature review [J].
Filardo, Giuseppe ;
Andriolo, Luca ;
Kon, Elizaveta ;
de Caro, Francesca ;
Marcacci, Maurilio .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (01) :35-46