Numerical Investigations of Gas-Liquid Two-Phase Flow in a Pump Inducer

被引:24
作者
Mansour, Michael [1 ,2 ]
Parikh, Trupen [2 ]
Engel, Sebastian [2 ]
Thevenin, Dominique [2 ]
机构
[1] Helwan Univ, Fac Engn, Mattaria Branch, Dept Power Mech Engn, Cairo 11718, Egypt
[2] Univ Magdeburg Otto von Guericke, Lab Fluid Dynam & Tech Flows, D-39106 Magdeburg, Germany
来源
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME | 2020年 / 142卷 / 02期
关键词
gas-liquid two-phase flow; pump inducers; volume-of-fluid (VOF) method; computational fluid dynamics (CFD); CENTRIFUGAL PUMP; CAVITATION CHARACTERISTICS; EXTERNAL PERFORMANCE; TIP CLEARANCE; IMPELLER; PATTERNS;
D O I
10.1115/1.4044651
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Inducers show generally a positive influence on the performance of centrifugal pumps in the two-phase regime, since they produce more uniform mixtures and increase the pressure before the impeller. However, the effect is much more pronounced in part-load compared to overload conditions. In this study, the air-water two-phase flow behavior in a pump inducer was numerically investigated. The main objectives were to clarify the effect of the inducer, the effective operating range, and to examine flow mixing. Several flow conditions were studied, covering part-load, optimal, and overload pumping conditions, together with different relevant gas volume fractions (1%, 3%, and 5%). The simulations were performed using a transient setup and a moving-mesh approach. Two-phase air-water interactions were modeled by the volume of fluid (VOF) method. After checking the proper discretization in space and time, the model was validated against experimental results, revealing excellent agreement. The numerical analysis was able to explain different effects of inducers in part-load and overload conditions. Under overload conditions, the flow separates, leading to the generation of axial vortices and to a negative pressure change across the inducer; additionally, the residence time is reduced, hindering mixing. These vortices are intensified as the gas volume fraction increases, reducing further the pressure downstream of the inducer. This is the reason why inducers can mainly be used in part-load and near optimal conditions in order to improve pumping of two-phase flows.
引用
收藏
页数:12
相关论文
共 47 条
[1]   Advanced Image Analysis of Two-Phase Flow inside a Centrifugal Pump [J].
Amoresano, A. ;
Langella, G. ;
Niola, V. ;
Quaremba, G. .
ADVANCES IN MECHANICAL ENGINEERING, 2014,
[2]  
[Anonymous], 21 FLUID DYN PLASM D
[3]  
Bakir F., 2004, International Journal of Rotating Machinery, V10, P15
[4]  
Campo A., 2010, POWER201027048 ASME, DOI DOI 10.1115/POWER2010-27048
[5]   Numerical and experimental study of cavitating flow through an axial inducer considering tip clearance [J].
Campos-Amezcua, Rafael ;
Khelladi, Sofiane ;
Mazur-Czerwiec, Zdzislaw ;
Bakir, Farid ;
Campos-Amezcua, Alfonso ;
Rey, Robert .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2013, 227 (08) :858-868
[6]  
Cappellino C. A., 1992, P 9 INT PUMPT US S T, P262
[7]   Characterization of a centrifugal pump impeller under two-phase flow conditions [J].
Caridad, Jose ;
Asuaje, Miguel ;
Kenyery, Frank ;
Tremante, Andres ;
Aguillon, Orlando .
JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2008, 63 (1-4) :18-22
[8]  
Cheng X. R., 2018, IOP Conference Series: Earth and Environmental Science, V163, DOI 10.1088/1755-1315/163/1/012107
[9]   Suppression of cavitation in inducers by J-Grooves [J].
Choi, Young-Do ;
Kurokawa, Junichi ;
Imamura, Hiroshi .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (01) :15-22
[10]  
d'Agostino L, 2017, CISM COURSES LECT, V575, P65, DOI 10.1007/978-3-319-49719-8_3