Self-centering second-generation patient-specific functionalized implants for deep orbital reconstruction

被引:11
作者
Zeller, Alexander-Nicolai [1 ]
Neuhaus, Michael Tobias [1 ]
Gessler, Nora [1 ]
Skade, Sandra [1 ]
Korn, Philippe [1 ]
Jehn, Philipp [1 ]
Gellrich, Nils-Claudius [1 ]
Zimmerer, Rudiger M. [1 ]
机构
[1] Hannover Med Sch, Dept Oral & Maxillofacial Surg, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
CAD/CAM implants; Orbital fracture; Navigation; Patient-specific; Intraoperative imaging; EXPERIENCE; NAVIGATION; HEAD; WALL;
D O I
10.1016/j.jormas.2020.12.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Deep and complete reconstruction of the orbital cavity has been shown to be essential for preventing enophthalmos and hypoglobus in patients with orbital defects or deformities. Additively manufactured patient-specific titanium implants provide unlimited options in design. However, implant malpositioning can still occur, even when intraoperative imaging and navigation are used. In this study, we investigated novel orbital implants containing features facilitating self-centering. Accuracy of implant placement and reconstruction of the orbital dimensions were compared retrospectively between self-centering second-generation patient-specific functionalized orbital implants (study group) and CAD-based individualized implants (control group). Design features of implants in the study group included functionalization with navigation tracks, a preventive design, and flanges so called stabilizers towards opposite orbital walls. Implant position was evaluated by fusion of preoperative virtual plans and the post-therapeutic imaging. Aberrances were quantified by 3D heatmap analysis. 31 patients were assigned to the study group and 50 to the control group, respectively. In the study group, most implants were designed with either one (n = 18, 58.06%) or two (n = 10, 32.26%) stabilizers. Twice (6.45%), one stabilizer had to be shortened intraoperatively. Implant fit analysis revealed a significantly more precise (p < 0.001) positioning in the study group (n = 22/31) than in the control group (n = 42/50). Self-centering second-generation patient-specific functionalized orbital implants showed significantly more accurate implant positioning, facilitating the transformation of virtual plans into patient's anatomy. The presented design provides an additional instrument for intraoperative quality control besides intraoperative imaging and navigation. (C) 2020 Published by Elsevier Masson SAS.
引用
收藏
页码:372 / 380
页数:9
相关论文
共 21 条
[1]   Retrospective analysis of 301 patients with orbital floor fracture [J].
Bartoli, Davina ;
Fadda, Maria Teresa ;
Battisti, Andrea ;
Cassoni, Andrea ;
Pagnoni, Mario ;
Riccardi, Emiliano ;
Sanzi, Marcello ;
Valentini, Valentino .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (02) :244-247
[2]   Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet [J].
Baumann, A ;
Burggasser, G ;
Gauss, N ;
Ewers, R .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (04) :367-373
[3]   Computer assistance for intraoperative navigation in ENT surgery [J].
Caversaccio, M ;
Freysinger, W .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2003, 12 (1-2) :36-51
[4]   Exophthalmometry: A comparative study of the Naugle and Hertel instruments [J].
Cole, HP ;
Couvillion, JT ;
Fink, AJ ;
Haik, BG ;
Kastl, PR .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 13 (03) :189-194
[5]   Severe distortion of an orbital titanium mesh implant after recurrent facial trauma: a potential threat to the orbital contents? [J].
Foletti, J. M. ;
Scolozzi, P. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2017, 55 (08) :836-838
[6]   EXPERIENCE IN THE USE OF CALVARIAL BONE-GRAFTS IN ORBITAL RECONSTRUCTION [J].
ILANKOVAN, V ;
JACKSON, IT .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1992, 30 (02) :92-96
[7]   Orbital volume analysis: validation of a semi-automatic software segmentation method [J].
Jansen, Jesper ;
Schreurs, Ruud ;
Dubois, Leander ;
Maal, Thomas J. J. ;
Gooris, Peter J. J. ;
Becking, Alfred G. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (01) :11-18
[8]   Patient-specific implant modification for alloplastic bridging of mandibular segmental defects in head and neck surgery [J].
Jehn, Philipp ;
Spalthoff, Simon ;
Korn, Philippe ;
Zeller, Alexander-Nicolai ;
Dittmann, Jan ;
Zimmerer, Ruediger ;
Tavassol, Frank ;
Gellrich, Nils-Claudius .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2020, 48 (03) :315-322
[9]   Classification and surgical management of orbital fractures: Experience with 111 orbital reconstructions [J].
Manolidis, S ;
Weeks, BH ;
Kirby, M ;
Scarlett, M ;
Hollier, L .
JOURNAL OF CRANIOFACIAL SURGERY, 2002, 13 (06) :726-737
[10]   STUDIES ON ENOPHTHALMOS .2. THE MEASUREMENT OF ORBITAL INJURIES AND THEIR TREATMENT BY QUANTITATIVE COMPUTED-TOMOGRAPHY [J].
MANSON, PN ;
GRIVAS, A ;
ROSENBAUM, A ;
VANNIER, M ;
ZINREICH, J ;
ILIFF, N .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (02) :203-214