Influence of Parameter on the Performance of a Standing-Wave Thermoacoustic Prime Mover

被引:3
|
作者
Murti, Prastowo [1 ,2 ]
Setiawan, Ikhsan [3 ]
Widyaparaga, Adhika [2 ]
Utomo, Agung B. S. [3 ]
Nohtomi, Makoto [4 ]
机构
[1] Univ Tidar, Dept Mech Engn, Fac Engn, Jl Kapten Suparman 39, Magelang 56116, Indonesia
[2] Univ Gadjah Mada, Dept Mech & Ind Engn, Fac Engn, Jl Tekn Utara, Yogyakarta 55281, Indonesia
[3] Univ Gadjah Mada, Fac Math & Nat Sci, Dept Phys, Sekip Utara BLS 21, Yogyakarta 55281, Indonesia
[4] Waseda Univ, Grad Sch Environm & Energy Engn, Nishi Tomita 1101, Honjo City, Saitama, Japan
来源
ADVANCES OF SCIENCE AND TECHNOLOGY FOR SOCIETY | 2016年 / 1755卷
关键词
SYSTEM;
D O I
10.1063/1.4958538
中图分类号
O59 [应用物理学];
学科分类号
摘要
The standing-wave thermoacoustic prime mover is a device to convert heat into work in the form of sound. It is one of the most potential applications for a thermoacoustic prime mover to utilize low-grade heat source to drive a refrigerator or electrodynamic linear alternator. Low efficiency of the device becomes interesting to be studied; it is because of no optimum heat exchange between the channel wall and the working gas that occur in the stack. The stack is the main part of the thermoacoustic prime mover in where the thermoacoustic energy conversion process takes place. The omega tau parameter is regarded as a nondimensional parameter determining the efficiency of the heat exchange in the stack and it depends on the hydraulic radius of the stack. This experiment was carried out by changing the hydraulic radius of the stack to control the value of omega tau The stack was made of a pile stainless steel wire mesh because it is easier to vary the hydraulic radius than another kind of stack. The length of the resonator is 1.28 m and air at atmospheric pressure is used to fill the resonator as the working gas. Experimental results show that omega tau affecting the onset temperature difference, frequency, pressure amplitude, and acoustic power. Finally, omega tau parameter is a useful property which is needed to be considered to enhance the performance of thermoacoustic prime mover.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Influence of working fluid on the performance of a standing-wave thermoacoustic prime mover
    Hao, X. H.
    Ju, Y. L.
    Behera, Upendra
    Kasthurirengan, S.
    CRYOGENICS, 2011, 51 (09) : 559 - 561
  • [2] Influence of Resonator Length on the Performance of Standing Wave Thermoacoustic Prime Mover
    Achmadin, Wahyu Nur
    Setiawan, Ikhsan
    Utomo, Agung Bambang Setio
    Nohtomi, Makoto
    ADVANCES OF SCIENCE AND TECHNOLOGY FOR SOCIETY, 2016, 1755
  • [3] Optimum packing factor of the stack in a standing-wave thermoacoustic prime mover
    Qiu, LM
    Chen, GB
    Jiang, N
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (08) : 729 - 735
  • [4] Numerical simulation for standing-wave thermoacoustic prime movers
    Ling, H
    Luo, EC
    Wu, JF
    Yang, M
    Li, XM
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 128 - 131
  • [5] Relation between Acoustic Impedance and Sound Intensity Amplification in a Stack of Standing-Wave Thermoacoustic Prime Mover
    Sahashi, Kazuki
    Sakamoto, Shin-ichi
    Kuroda, Kentaro
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (07)
  • [6] Design, Construction and Evaluation of a Standing Wave Thermoacoustic Prime Mover
    Setiawan, Ikhsan
    Murti, Prastowo
    Achmadin, Wahyu N.
    Utomo, Agung B. S.
    Nohtomi, Makoto
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE AND EXHIBITION OF SUSTAINABLE ENERGY AND ADVANCED MATERIALS 2015 (ICE-SEAM 2015), 2016, 1717
  • [7] Experimental investigation of a thermoacoustic refrigerator driven by a standing wave twin thermoacoustic prime mover
    Hariharan, N. M.
    Sivashanmugam, P.
    Kasthurirengan, S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08): : 2420 - 2425
  • [8] Experimental and simulation studies on the performance of standing wave thermoacoustic prime mover for pulse tube refrigerator
    Kamble, Bharatbhushan V.
    Kuzhiveli, Biju T.
    Kasthurirengan, S.
    Behera, Upendra
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08): : 2410 - 2419
  • [9] STANDING-WAVE THERMOACOUSTIC ENGINES
    Novotny, Petr
    Vit, Tomas
    Vestfalova, Magda
    Lopes, Jose
    EFM11 - EXPERIMENTAL FLUID MECHANICS 2011, 2012, 25
  • [10] Numerical and Theoretical Investigations on Twin Standing-wave Thermoacoustic Prime Movers
    Guan, Lixian
    Zhao, Dan
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):