Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma

被引:3
作者
Kampmeier, J [1 ]
Eisert, B [1 ]
Buchwald, HJ [1 ]
Lang, GK [1 ]
Lang, GE [1 ]
机构
[1] Univ Ulm, Augenklin Poliklin, D-89075 Ulm, Germany
关键词
glaucoma; perimetry; FDP; HFA;
D O I
10.1055/s-2001-13075
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To compare frequency doubling perimetry (FDP) versus standard automated perimetry in glaucoma. To evaluate the reproducibility of both methods. Patients and Methods: All the patients were tested (full threshold test) twice with both FDP (N-30) and Humphrey Field Analyzer II Model 750 (HFA) (30-2 procedures) in random sequence, within one day. The parameters mean deviation (MD), pattern standard deviation (PSD) and measured thresholds per quadrant and center areas were evaluated for FDP/HFA comparison in 45 glaucoma patients. The same parameters were used for testing the reproducibility of FDP (n = 46) and HFA (N = 39). Additionally, the center and each quadrant area were checked for any deviation in the total deviation probability plots. For statistical analysis Kappa coefficients and Bland/Altman plots were used. Results: An average MD (FDP vs HFA) of -7.3+/-5.8 dB vs -8.9 +/- 7.6 dB and PSD of 6.9 +/- 2.4 dB vs 6.5 +/- 3.6 dB were found. Kappa coefficients denote marginal accordance (kappa: 0.11-0.38) for area deviations. In a total of 225 areas HFA detected 191 deviations and FDP 165. HFA measured more negative deviation compared with FDP in the case of MD < -15 dB. The reproducibility was 0.98 (MD) and 0.92 (PSD) for FDP and 0.98 (MD) and 0.95 (PSD) for HFA (95% confidence interval). Conclusions: There was great conformity between FDP and HFA in glaucoma patients. HFA detected more deviations in the total deviation probability plots than FDP. There was a high reproducibility of both methods. FDP is an appropriate tool for detecting visual field loss in glaucoma patients.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 50 条
  • [31] Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss
    Saric, D
    Mandic, Z
    Ivekovic, R
    Geber, MZ
    Bencic, G
    Tomic, Z
    Grgic, D
    COLLEGIUM ANTROPOLOGICUM, 2005, 29 : 111 - 113
  • [32] Eye Movement Perimetry and Frequency Doubling Perimetry: clinical performance and patient preference during glaucoma screening
    Najiya Sundus Kadavath Meethal
    Johan J. M. Pel
    Deepmala Mazumdar
    Rashima Asokan
    Manish Panday
    Johannes van der Steen
    Ronnie George
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 1277 - 1287
  • [33] Predictive value of frequency doubling technology perimetry for detecting glaucoma in a developing country
    Mansberger, SL
    Johnson, CA
    Cioffi, GA
    Choi, D
    Krishnadas, SR
    Srinivasan, M
    Balamurugan, V
    Kim, U
    Smith, SD
    Wilkins, JH
    Gritz, DC
    JOURNAL OF GLAUCOMA, 2005, 14 (02) : 128 - 134
  • [34] Combining Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry for Glaucoma Detection
    Mwanza, Jean-Claude
    Warren, Joshua L.
    Hochberg, Jessica T.
    Budenz, Donald L.
    Chang, Robert T.
    Ramulu, Pradeep Y.
    JOURNAL OF GLAUCOMA, 2015, 24 (08) : 561 - 567
  • [35] The Impacts of Face Mask Use on Standard Automated Perimetry Results in Glaucoma Patients
    Bayram, Nurettin
    Gundogan, Medine
    Ozsaygili, Cemal
    Vural, Esra
    Cicek, Ayse
    JOURNAL OF GLAUCOMA, 2021, 30 (04) : 287 - 292
  • [36] Comparison of Visual Field Results of Humphrey Matrix Perimetry and Standard Automated Perimetry with SITA Strategy in Glaucoma and Ocular Hypertension Subjects
    Yilmaz, Pinar Topcu
    Bozkurt, Banu
    Irkec, Murat
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02): : 98 - 103
  • [37] Glaucoma diagnostic performance of humphrey matrix and standard automated perimetry
    Yoon Pyo Nam
    Seong Bae Park
    Sung Yong Kang
    Kyung Rim Sung
    Michael S. Kook
    Japanese Journal of Ophthalmology, 2009, 53 : 482 - 485
  • [38] Motion automated perimetry in glaucoma
    Brusini, P
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 : 16 - 17
  • [39] Glaucoma diagnostic performance of humphrey matrix and standard automated perimetry
    Nam, Yoon Pyo
    Park, Seong Bae
    Kang, Sung Yong
    Sung, Kyung Rim
    Kook, Michael S.
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (05) : 482 - 485
  • [40] Identifying "Preperimetric'' Glaucoma in Standard Automated Perimetry Visual Fields
    Asaoka, Ryo
    Iwase, Aiko
    Hirasawa, Kazunori
    Murata, Hiroshi
    Araie, Makoto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) : 7814 - 7820